RCDD-002 Exam Questions
357 real RCDD-002 exam questions with expert-verified answers and explanations. Page 7 of 8.
- Question #301
During the execution phase of a program a stakeholder complains to the program manager that they did not receive critical communications about one of the component projects. What s...
- Question #302
The program sponsor returns from a board of directors meeting alter identifying a significant risk to the program schedule. This may Impact the program's benefits realization. What...
- Question #303
Throughout a multiyear program, component projects are transitioned to the customer. During the project acceptance phase, a potential risk is identified and brought to the program...
- Question #304
The new performance financial system is delivered to all business entities on time following a one- year implementation program. After six months of utilization the global finance...
- Question #305
A voice over IP network that converges voice capabilities with softphones, video communications, instant messaging is referred to as
- Question #306
The options for termination an unshielded twisted pair cable for a video surveillance camera at the camera end are an 8-pin 8 conductor outlet and
- Question #307
When sizing an underground entrance facility, what is the MINIMUM amount of 103 metric designator conduits (4 trade size) that should be specified by the ICT distribution design?
- Question #308
Which of the following is TRUE for telecommunications spaces?
- Question #309
What is the MINIMUM fire rating for telecommunications spaces walls and wall linings, if not specified otherwise by local Authority Having Jurisdiction (AHJ)?
- Question #310
In a PTP network using optical fiber, the ________ is responsible for media conversions from the optical fiber to the balanced twisted pair network within the residence.
- Question #311
When estimating an ICT distribution designer project timeline schedule based on the scope of work, which two scheduling methods use network diagrams to integrate logical activities...
- Question #312
For optical fiber cabling, which of the following test instruments is used to locate and identify any anomalies?
- Question #313
In which of the following design phases does the ICT distribution designer perform coordination with stakeholders and other disciplines (e.g.. mechanical, architectural, electrical...
- Question #314
When designing horizontal pathways, the ICT distribution designer should consider the design's ability to (Select two options.)
- Question #315
In new construction, what is the percentage of pay phones that must be equipped with volume controls?
- Question #316
Exhibit: What does this international symbol stands for?
- Question #317
Coupling with electrical circuits can create inductive interference to telecommunications facilities. Which of the following can decrease the coupling effect?
- Question #318
One interior TTY must be provided at locations defined as public accommodations with ________ or more pay telephones.
- Question #319
In an office area, a consultant needs to add the location of a fax machine to the plan. What is the approximated floor area that a fax machine occupies?
- Question #320
What is the MINIMUM distance from the edge of a pool or other water hazards for a weatherproof enclosure?
- Question #321
Exhibit: A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (American with Disabilities...
- Question #322
You are designing distribution for a seven unit townhouse with in slab conduits. What is the MINIMUM number of 27 mm (1 in) rigid PVC Type 2 or metallic conduit that is required to...
- Question #323
You have just finished a design calling for 15 telecommunications outlets. You received word that the owner has increased his requirements by 40%. What size commercial DD (distribu...
- Question #324
Which service is NOT typical of Grade 1?
- Question #325
You are designing a multi-story dwelling and need to place the CTR's. Every floor is not available. What is the alternate spacing for the CTRs?
- Question #326
You are designing a system requiring the transmission of data. Your system must perform higher than ________ kHz in order to do so.
- Question #329
A network that has a single broadcast domain is referred to as a ______ network.
- Question #330
In addition to thoroughly knowing the national electrical, communications, safety and building codes, standards, and regulations for a particular project, what additional entities...
- Question #331
Standard definition TV (SDTV) and high definition TV (HDTV) are both available in two resolution formats called
- Question #332
What is the recommended MINIMUM setback for dirt (spoil) piles from the edge of an excavation (trench, pit, etc.)?
- Question #333
In addition to providing for current occupant needs, the horizontal pathway system design shall allow for future growth of ___% unless otherwise specified by the client.
- Question #334
Which of the following may be reviewed by an ICT distribution designer during procurement management?
- Question #335
An ICT distribution designer is determining the size of the equipment room (ER). The building has a usable floor area of 1393.5 m2 (15,000 ft2). What is the MINIMUM size of the ER...
- Question #336
Telecommunications designs should include which three elements?
- Question #337
In the context of producing sound, molecules that move further apart from each other is known as
- Question #338
The recommendation for installation of a cable tray system in buildings with removable ceiling tiles is that they be installed with a clearance of ______ or greater above ceiling t...
- Question #339
Telecommunications space sizing guidelines for horizontal cabling distribution are based on distributing telecommunications services to one individual work area per how much usable...
- Question #340
The size of the pathway using slots should be one slot sized at ___________ for up to 3716 m2 (40,000 ft2) of usable floor space served by that backbone distribution system.
- Question #341
An ICT distribution designer installed a 62.5 mm/850 nm fiber optic cable from Building A to Building B with a distance of 1000 m (3280 ft). At Building B the designer fusion splic...
- Question #342
The ICT distribution designer discovers a bonding and grounding conflict when reviewing the contract information, provided by the contract administration team, that the stated requ...
- Question #343
In a joint trench using concrete, what is the MINIMUM vertical and horizontal separation between the electrical and the ICT distribution designer conduits?
- Question #344
Which two of the following are fire protection considerations when designing telecommunications spaces? (Choose two.)
- Question #345
Building automation systems (BAS) cabling may include the horizontal electrical services from the electrical panel using a modular partitioned cable tray or raceway. By combining h...
- Question #346
The owner's ICT distribution designer is forwarded an RFI from the ICT contractor requesting clarification on certification testing REQUIRED by the specifications for the horizonta...
- Question #347
The _____ shall be located in an accessible non-sterile area on each floor of the medical facility.
- Question #348
What are the two types of typical bid delivery structures? (Choose two.)
- Question #349
When designing conduit runs as part of a horizontal pathway solution, what are two BEST practices the ICT distribution designer should follow? (Choose two.)
- Question #350
Which of the following BEST describes the frequency in alternating current (AC) power?
- Question #351
Which of the following is the type of cable used in an electronic access control system door strike, card reader, door contact, and request for exit?
- Question #352
Which of the following is a MAJOR factor in fiber cabling performance that is verified through manufacturer's specification?