RCDD-002 Exam Questions
357 real RCDD-002 exam questions with expert-verified answers and explanations. Page 2 of 8.
- Question #51ICT Design Fundamentals and Project Management
During bidding the ICT distribution designer should review the bid responses for compliance and completeness. Afterwards, the designer should report the findings and recommendation...
bid evaluationstakeholder communicationproject managementcompliance review - Question #52ICT Design Fundamentals and Project Management
An RFQ usually provides more detail than RFP in selection material such as
RFQ/RFP procurementspecification detail levelsvendor selectionproject management - Question #53ICT Design Fundamentals and Project Management
A system integration approach of a BAS on to a LAN can usually reduce the cost of cabling- related changes by
BAS integrationLAN convergenceCabling cost reductionSystem architecture - Question #54ICT Design Fundamentals and Project Management
Which two of the following items should be considered for inclusion in a comprehensive working outline of a SoW? (Select two options.)
Statement of WorkScheduleTechnical requirementsProject planning - Question #55ICT Design Fundamentals and Project Management
Which of the following team members is responsible for ensuring compliance with the contract documents (CD)?
contract complianceproject rolesdistribution designerresponsibility assignment - Question #56ICT Design Fundamentals and Project Management
In a design type Scope of Work (SoW) the ICT distribution designer is responsible for providing
Scope of Work (SoW)Design-type deliverablesDesigner responsibilitiesICT specifications - Question #57Structured Cabling Systems (Copper and Optical Fiber)
The marketing department of a firm has tasked the organization to design a structured cabling system allowing them to support either 10GBaseT or HDBASE-T. The budget requires that...
10GBaseTHDBASE-TCategory 6ACopper cabling standards - Question #58Structured Cabling Systems (Copper and Optical Fiber)
What category/class of cabling does BICSI recommend for the MINIMUM performance level of horizontal balanced twisted-pair cabling?
Horizontal cablingTwisted-pairCategory/Class standardsBICSI requirements - Question #59ICT Design Fundamentals and Project Management
Who prepares the submittals that are reviewed and approved to ensure that the client's design criteria is met in regards to material selection?
project managementsubmittalscontractor responsibilitiesmaterial approval - Question #60
Which two of the following roles does an ICT distribution designer use to ensure a timely and cost-effective telecommunications construction project? (Choose two.)
- Question #61
A 3 trade size conduit is sized at
- Question #62ICT Design Fundamentals and Project Management
Which of the following options BEST describes Request for Quote (RFQ)?
RFQProcurementMaterial selectionBidding process - Question #63Structured Cabling Systems (Copper and Optical Fiber)
Which of the following transmitter light sources has a MINIMUM bandwidth of 4700 MHz/km (EMB) at 850 nm">
fiber optic bandwidthOM4 specificationsmultimode fiberEMB - Question #64
A project's installation start involves a Kickoff Meeting and the General Contractor's Coordination Meeting. As part of the designer's responsibilities, which two of the following...
- Question #65Structured Cabling Systems (Copper and Optical Fiber)
An Ethernet passive optical network (EPON) uses an aggregation device called an optical line terminal (OLT). An OLT can support a MINIMUM of______subscribers per port using a passi...
EPONOLTPassive Optical SplitterSubscriber Capacity - Question #66Pathways and Spaces
What is the RECOMMENDED bend radius of a conduit with an internal diameter of 51 mm (2 in)?
conduit bend radiusindustry standardspathway designcable routing - Question #67Structured Cabling Systems (Copper and Optical Fiber)
Using a vertical cable support structure can create issues for the cable attached to the pathway Several issues can result It the support work is not clone correctly. Which two of...
cable support systemsmechanical stresscable integrityfiber and copper properties - Question #68Pathways and Spaces
The MINIMUM required for backbone floor to floor pathways is five (5) sleeves each being 103 mm (four trade size) in diameter. What increase in usable floor space should another 10...
backbone pathwayssleeve sizingfloor space capacitypathway design - Question #69ICT Design Fundamentals and Project Management
An ICT distribution designer is reviewing a client's site information (spaces and pathways) to determine network technology and equipment selection. This is referred to as a_______...
bottom-up designsite surveydesign methodologynetwork planning - Question #70ICT Design Fundamentals and Project Management
Which stakeholder of a project team is responsible to provide closeout documentation to the client?
Project ManagementStakeholder RolesCloseout DocumentationProject Team Responsibilities - Question #71Pathways and Spaces
The size and number of conduits or sleeves used for backbone pathways depend on the usable floor space served by the backbone distribution system. What is the MINIMUM trade size of...
Backbone pathwaysConduit sizingMinimum specificationsTelecommunications infrastructure - Question #72Structured Cabling Systems (Copper and Optical Fiber)
Which two of the following are means in which radiated interference primarily enters electronic devices? (Select two options.)
electromagnetic interferencecable shieldingEMC/RFIproximity effect - Question #73ICT Design Fundamentals and Project Management
What step can be a phase of the Bidding and Negotiating process?
Project ManagementBidding ProcessProposal EvaluationProcurement - Question #74Structured Cabling Systems (Copper and Optical Fiber)
How many classes of telecommunications administration are there?
TIA-606telecommunications administrationadministrative classescabling standards - Question #75ICT Design Fundamentals and Project Management
For a cost estimate, an ICT distribution designer should produce a document listing each task with a cost placed beside them. The type of document used is a
Statement of Work (SoW)cost estimationproject documentationdesign deliverables - Question #76Telecommunications Rooms and Data Centers
Based on the estimated work area size, what is the MAXIMUM number of work areas that a telecommunications enclosure shall serve?
telecommunications enclosure capacitywork area sizingBICSI standardsinfrastructure design - Question #77
Which two of the following are included in the ICT distribution designer's role of vendor and contractor coordination'? (Select two options.)
- Question #78Bonding, Grounding, and Electrical Protection
Which of the following terms is often used to describe two parallel paths that have identical conductive terminations to two separate grounding reference points?
ground loopgrounding systemsEMI preventionbonding - Question #79ICT Design Fundamentals and Project Management
Which two of the following may the ICT distribution designer need to provide in order to identify the BEST solutions for the client's need? (Select two options.)
Design inputs and requirementsBudget and timeline constraintsSolution identificationProject planning - Question #80Pathways and Spaces
When designing for horizontal pathways in an environment that requires fire-stopping for penetrating a rated wall, what is the MAXIMUM till ratio for telecommunications cabling in...
Cable tray fill ratioHorizontal pathwaysFire-stopping penetrationsRated wall penetrations - Question #81Pathways and Spaces
In a contiguous properly environment (e. g., where campus backbone cables exist), which two of the following are CRITICAL factors to understand for maintenance and growth purposes?...
cable routing and pathwaysinfrastructure documentationcable compositioncapacity planning - Question #82ICT Design Fundamentals and Project Management
ICT project installation issues that require coordination with mechanical, electrical and/or other "trades" can be BEST accomplished by
RFI procedureTrade coordinationProject documentationCommunication protocols - Question #83Structured Cabling Systems (Copper and Optical Fiber)
For the MAXIMUM flexibility of a cabling system in a hierarchical star topology, ALL backbone cables and links to ER's should be terminated at the
hierarchical star topologymain cross-connectbackbone terminationcabling hierarchy - Question #84
Which of the following two items are examples of items associated with a submittal? (Select two options.)
- Question #85
Which two of the following are ADVANTAGES of aerial pathways? (Select two options.)
- Question #86ICT Design Fundamentals and Project Management
Which two of the following documents MUST be submitted by the communication's project contractor for review and approval? (Select two options.)
project documentationshop drawingstest reportscontractor submissions - Question #87
When responding to a submittal that has been rejected and/or has comments written by a reviewer, the ICT distribution designer may need to perform which two of the following action...
- Question #88
A large international manufacturing company is centralizing its IT which is currently spread over 16 countries. The transition means physically regrouping the infrastructure and al...
- Question #89
To create market advantage, a program sponsor requests accelerating the implementation of a new manufacturing process that is based on a recently improved system component. The pro...
- Question #90
A program manager evaluates conflicting stakeholder demands associated with cost, schedule, and intended benefits. The implementation team has a strong interest in cost and schedul...
- Question #91
A program to implement a new payroll processing system at a healthcare company is nearing completion and is under budget. What should the program manager do next?
- Question #92
A program manager has a multiple-project program that is scheduled to be completed by year's end. During the program delivery phases of the protects several mandatory changes are i...
- Question #93
A program governance board mandates that phase gate reviews must be held so each component project can be reviewed and individually authorized to proceed to the next phase. Trackin...
- Question #94
A program manager concurrently implements a software program at four client locations. The client's objective is to maintain quality while shortening the software implementation ti...
- Question #95
An R&D group director approves a major program's charter although the director has a high level of understanding of the program's scope (hoy are unsure of how the program manager c...
- Question #96
A component is scheduled to close at the end of the week. What should the program manager verity prior to allowing the component to close?
- Question #97
During program execution, a program manager receives feedback from an executive sponsor (hat some program stakeholders may not understand the intended benefits of the program. Whic...
- Question #98
During a program's definition phase, it is determined that the best approach for delivering the programs intended benefits is to supplement corporate resources with the procurement...
- Question #99
A program is midway through the program delivery phase when a key stakeholder asks if the program is meeting its defined objectives. How should the program manager demonstrate the...
- Question #100
The project managers for component projects A and B schedule the same resource to perform tasks during the same timeframe, resulting in an over-allocation. The program manager revi...