- Question #267
Refer to the exhibit. An engineer is creating a new data center design for a customer. The design must support virtual applications, enhance network resilience, and meet these requ...
- Question #268
A company wants to use the Cisco hyperconverged system in two data centers. The company plans to implement five HX servers in each data center, and there is no connectivity between...
- Question #269
A customer with a single data center wants to provide resiliency in the form of an additional hosting location. The customer's engineering team requested asynchronous replication f...
- Question #270
An engineer needs to design a network solution for a client-server farm that uses a pair of Cisco Nexus 9000 Series Switches that are configured with vPCs. Each server must connect...
- Question #271
A Cisco engineer is using a PowerShell script to create a service profile template on Cisco UCS Manager. After defining the server pools and other templates, the engineer must ensu...
- Question #272
An architect is gathering technical requirements for a large-scale data center with up to 3000 Ethernet ports and 70 ToR switches. The stakeholders agreed that if a ToR switch beco...
- Question #273
A SAN engineer needs to connect a Fibre Channel storage array to a Cisco MDS 9000 Series Switch by using an 8-Gbps interface. The switch must meet these requirements: - ensure stor...
- Question #274
An architect is designing a storage solution for a Cisco UCS server infrastructure with these requirements: - identical deployment of servers - can add vHBAs to a group of servers...
- Question #275
Refer to the exhibit. An engineer needs a solution to extend Fibre Channel traffic between multiple sites. The IPsec tunnels must be used to encrypt and secure the traffic. Which t...
- Question #276
Refer to the exhibit. A Cisco engineer is configuring Cisco Nexus 7000 Series Switches. To simplify initial configuration verification and vPC+/HSRP troubleshooting, the engineer c...
- Question #277
Refer to the exhibit. FCoE is used in the topology between the SAN Storage devices and SAN- Core routers. After noticing traffic drops to hosts accessing SAN-B storage, the enginee...
- Question #278
Refer to the exhibit. An engineer must deploy NEW-VRF-001 in the data center. All hosts require full reachability with all other hosts, no matter on which pod the host deployment o...
- Question #279
Which programming model is vendor-agnostic and combines operational and configuration data in the same container?
- Question #280
A network engineer needs to configure a high availability feature for a data center that uses a Cisco Nexus 7700 Series Switch that is configured with dual supervisors. The feature...
- Question #282
An engineer must design a solution with storage reachability between 100 physical servers and a storage array. The storage array connectivity is to a SAN switch that is limited to...
- Question #283
An engineer deploys a Cisco UCS environment with the storage array directly attached to the Fabric Interconnects. The operations team mandates that the solution must not require th...
- Question #284
Refer to the exhibit. A Cisco engineer is configuring a Cisco UCS integrated infrastructure for SAP HANA that consists of 8 x Cisco UCS B/C480-M5 servers for SAP HANA and 4 x Cisco...
- Question #285
A large financial institution hosts all customer data in a critical data center with a single physical location. Top management is concerned about the risk of a single-site failure...
- Question #286
To help automate the vHBA configuration process, a network engineer is configuring vHBA template pairs on UCS. The engineer is creating primary and secondary templates to define ho...
- Question #287
Refer to the exhibit. An engineer builds a data center network design using EVPN technology. Within the design, the fabric acts as a gateway. Traffic from host X to host Y must pas...
- Question #288
Refer to the exhibit. A Cisco engineer is configuring a data center design scenario with Cisco MDS 9000 Series Switches. The cut-through routing mode is chosen for improved read op...
- Question #289
An engineer must connect a Cisco UCS Fabric Interconnect to a storage array using a Fibre Channel protocol. The SAN must be directly connected to the UCS fabric interconnects using...
- Question #290
An enterprise is experiencing transmission errors and excessive delays over their WAN when backing up user workstations. A systems architect decided to resolve the problems by cent...
- Question #292
Refer to the exhibit. A Cisco engineer is planning a data migration job in heterogeneous SANs where the existing and new storage devices for the migration are already connected to...
- Question #293
Refer to the exhibit. Fiber links are provisioned directly between the spine and leaf switches in the given LAN topology. A /30 prefix has been configured over each fiber link to p...
- Question #294
A midsize corporation with significant data-storage requirements is planning to deploy RFC 3720- based technology in its data center to provide efficient and reliable block-level s...
- Question #295
A Cisco engineer is analyzing a customer environment where dozens of VMs are running on a physical server and UCS chassis are cascaded. The setup uses two ISLs in a port channel to...
- Question #296
An engineer needs to design a network environment in a data center that uses Cisco Nexus 9000 Series Switches The solution must meet these requirements: - interoperate with 802.1D...
- Question #297
An engineer working for a private data center with an employee ID 4947.57 424 designs a storage area network solution. The requirement is to apply QoS to ensure that Fibre Channel...
- Question #298
A network architect is designing a storage network to connect to an existing IP network over 100G Ethernet ports for multiple hosts. The architect decided to require iSCSI multipat...
- Question #299
Refer to the exhibit. A network engineer must improve high availability within the given UCS infrastructure. The engineer configured central nodes A and B in cluster mode to ensure...
- Question #300
A network architect wants to automate data center LAN configuration by use of Kubernetes, aligned with Cisco best practices for underlay and overlay provisioning. The automation mu...
- Question #301
A networking team must implement a new management solution for the network devices at their organization. The solution must meet these requirements: - It must enable seamless monit...
- Question #302
A Cisco engineer is discussing a data center design scenario that consists of 24 Cisco UCS B200M6 Wade servers, 2 Cisco UCS 6454 Fabric Interconnects, and 3 Cisco UCS 5108 server c...
- Question #303
A company's data center is currently running on a traditional SAN architecture with Cisco UCS C200 M5 Blade Servers, producing 1000 IOPS. The SAN is becoming a performance bottlene...
- Question #304
A network engineer needs to design Layer 2 connectivity for a subnet between two data centers using VXLAN with Cisco Nexus switches. The engineer must ensure seamless host mobility...
- Question #305
Refer to the exhibit. Two Cisco Nexus 9000 Series Switches exchange OSPF routing information with R1. Which action accomplishes this goal?
- Question #306
A network engineer must design a high-performance, lossless Ethernet network to support AI workloads in a data center. The network uses a spine-leaf topology with Cisco Nexus 9000...
- Question #307
A data center with high network-traffic demands is facing challenges related to link throughput, with recent reports of significant traffic congestion and performance degradation....
- Question #308
Refer to the exhibit. A company must implement a multitenant environment for DEV and PROD application teams. The design must support end-to-end route isolation for remote external...
- Question #309
The network engineering team at a large corporation operates a critical data center with stringent business requirements for network reliability and high availability. EIGRP is use...
- Question #310
A company is planning to improve the segmentation of its data center network to isolate traffic of different clients across various parts of the facility. The solution must be high...
- Question #311
An international corporation migrates its primary and secondary data centers to Cisco ACI. The new architecture must include a disaster recovery solution for critical applications...
- Question #312
A network engineer must design a UCS SAN configuration for vNIC port eth0, which is currently configured directly via the adaptor. The engineer set the Connection Policies option t...
- Question #313
An AI/ML team is designing a fraud-detection model for an online banking application. The system must be able to handle a high volume of transaction data, and the models must be tr...
- Question #314
An organization deploys Cisco UCS-X Series servers in the data center. The deployment must have optimal BIOS configuration to maximize performance for memory-intensive applications...
- Question #315
An enterprise recently provisioned multiple new servers in their data center using service profile templates on Cisco UCS. Server 2 now requires two additional vNICs. How must the...
- Question #316
An engineer must complete vNIC and vHBA allocations for 16 new servers. All servers currently have the same requirements, but the company wants to be prepared for a future update t...
- Question #317
Which vNIC/vHBA Placement policy should be selected in Cisco UCS Manager to ensure that only dynamic and static vNICs and vHBAs are explicitly assigned to the policy?
- Question #318
An engineer must create a solution for server deployment in a multitenant UCS environment with UCS Central. The solution must: - Make use of centralized WWPN and IP pools. - Define...