D-PEMX-DY-23 Exam Questions
135 real D-PEMX-DY-23 exam questions with expert-verified answers and explanations. Page 2 of 3.
- Question #51PowerEdge MX Storage Configuration
When a SAS IOM is power cycled, how much time does it take for the storage-IOM to display mapping information?
SAS IOMpower cyclestorage mappingtiming - Question #52PowerEdge MX Management and Troubleshooting
Which is the minimum iDRAC license required to use the Platform Restore feature of the Lifecycle Controller?
iDRAC Enterprise licensePlatform RestoreLifecycle Controllerlicensing - Question #53PowerEdge MX Management and Troubleshooting
An administrator needs to start collecting detailed data points on the PowerEdge MX7000 power usage. What is the minimum requirement?
OME-M Advancedpower monitoringdata collectionlicensing - Question #54PowerEdge MX Management and Troubleshooting
A server administrator wants to configure chassis power, thermal, and fans metric reports on a PowerEdge MX7000 chassis. Which type of license is required?
OME-M Advancedchassis metricsthermal reportingfan metrics - Question #55PowerEdge MX Management and Troubleshooting
Refer to the exhibit. A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chass...
quad-port mezzanineMX7116ntwo-chassis configurationnetwork troubleshooting - Question #56PowerEdge MX Concepts and Architecture
What component enables the MX840c compute sled to have this configuration? 4 x CPUs 4 x mezzanine cards 2 x mini mezzanine cards 48 DDR4 DIMM slot
MX840cprocessor expansion modulemezzanine slotsarchitecture - Question #57PowerEdge MX Networking Configuration
A server sled has a single mezzanine card installed in the correctly supported slot. To which IOM fabric(s) does the sled have access?
mezzanine cardFabric A1IOM fabricsled connectivity - Question #58PowerEdge MX Management and Troubleshooting
A company receives their first MX7000 chassis. They connect all the provided power supply cables into two different PDUs on different power grids for redundancy. Each of the six po...
power redundancy policyPSU configurationchassis powertroubleshooting - Question #59PowerEdge MX Networking Configuration
A system administrator must interface the compute sleds of an MX7000 chassis to a Z9432F-ON in a single SmartFabric. Which FEM IOM is required?
SmartFabricMX8116n FEMZ9432F-ONIOM selection - Question #60PowerEdge MX Management and Troubleshooting
When performing "A1 the Box" management, what must be done to successfully connect to the Management Module?
Management ModulePuTTYserial connectioninitial setup - Question #61PowerEdge MX Management and Troubleshooting
A system administrator is designing a solution for a customer who will be purchasing a large number of PowerEdge MX7000 chassis. For ease of management, they would like to have the...
multi-chassis management groupMX7000 scalabilitychassis count limit - Question #62PowerEdge MX Storage Configuration
On which generation of server was the BOSS-N1 controller introduced?
BOSS-N1 controllerserver generationboot storage - Question #63PowerEdge MX Networking Configuration
Which statement describes L2 Multicast as implemented on the PowerEdge MX7000 IOM?
L2 MulticastMLD snoopingIGMPIOM networking - Question #64PowerEdge MX Networking Configuration
In the External Fabric Manager OME-M, what programming interface is used to manage the fabric?
External Fabric ManagerOME-MREST APIfabric management interface - Question #65PowerEdge MX Management and Troubleshooting
What automatically opens a support case with technical support and collects the PowerEdge MX system state information that is required for troubleshooting an issue, then sends it s...
SupportAssist Enterpriseautomated support casesystem state collection - Question #66PowerEdge MX Management and Troubleshooting
A system administrator must carry out a SupportAssist log collection on an MX750c sled using iDRAC that includes operating system logs. What is required?
SupportAssist log collectioniDRAC Service ModuleOS logsiDRAC requirements - Question #67PowerEdge MX Storage Configuration
An administrator is configuring a fully populated MX5016s storage sled to be accessed by four MX740c compute sleds. Each compute sled has an H745P Jumbo PERC installed. The disks i...
MX5016s storage sledDrive-Assigned storagedisk distributionH745P PERC - Question #68PowerEdge MX Concepts and Architecture
What is the maximum supported drive configuration on a PowerEdge MX840c compute sled?
MX840cdrive configurationcompute sled specs - Question #69PowerEdge MX Concepts and Architecture
Which component on the PowerEdge MX7000 uses a hot-plug serviceability model?
hot-plug serviceabilitycompute sledMX7000 components - Question #70PowerEdge MX Concepts and Architecture
What is the benefit of C22 power inlet connectors on the MX7000 chassis?
C22 power inletexhaust temperaturePSU connectorthermal design - Question #71PowerEdge MX Installation and Configuration
A system administrator must obtain the correct rail and cable management to install a newly purchased MX7000 chassis into a rack. What type of rail and cable management is supporte...
rack installationstatic railstrain relief barMX7000 installation - Question #72PowerEdge MX Networking Configuration
Which MX7000 feature allows an administrator to virtualize network WWN and MAC addresses?
Identity PoolWWN virtualizationMAC address virtualizationnetwork identity - Question #73PowerEdge MX Installation and Configuration
What are the required components for a PowerEdge MX7000 Minimum to POST configuration?
minimum to POSTpower supply unitMX7000 configuration - Question #74PowerEdge MX Management and Troubleshooting
While servicing an MX7000 chassis a system administrator logs into OME-M and receives a Chassis Mismatch error. What should be the next step taken by the administrator?
chassis mismatch errorOME-MIOM configurationtroubleshooting steps - Question #75PowerEdge MX Concepts and Architecture
Once power is applied to the chassis, what is the next sequence after MM completes booting?
power-on sequencemanagement module bootLCD panelchassis startup - Question #76PowerEdge MX Management and Troubleshooting
To which component can a firmware update be applied without affecting any applications running on the server?
firmware updateiDRACnon-disruptive updatelive firmware - Question #77PowerEdge MX Networking Configuration
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?
SmartFabric ServicesFabric Agentswitching node managementSFS architecture - Question #78PowerEdge MX Management and Troubleshooting
Where is a valid storage location for extracting the full MX7000 chassis logs package?
chassis log collectionCIFSlog storage locationOME-M - Question #79PowerEdge MX Installation and Configuration
What type of power cord connects to the PSU side of a PowerEdge MX7000?
power cordC21 connectorPSU connectionMX7000 installation - Question #80PowerEdge MX Concepts and Architecture
In an MX7000, which components are cooled by the rear fans?
rear fansthermal managementIOM coolingmanagement module cooling - Question #81PowerEdge MX Installation and Configuration
In addition to one compute sled, one management module, and one IOM, what is the minimum required HW configuration on the PowerEdge MX7000 to POST?
minimum configurationPOST requirementspower supply unitsMX7000 - Question #82PowerEdge MX Networking Configuration
Which uplink configuration combination of the Top of the Rack Switch and the MX7000 Management Module is supported?
uplink configurationauto negotiationManagement ModuleTOR switch - Question #83PowerEdge MX Concepts and Architecture
Which section of the PowerEdge MX7000 chassis provides a structure for mounting PSUs and sleds?
chassis structureMain ChassisPSU mountingsled mounting - Question #84PowerEdge MX Storage Configuration
In the assigned mapping of the MX5016s storage sled what is an assignment option used for independent storage to be mapped to a compute sled?
MX5016sdrive-assignedstorage mappingcompute sled - Question #85PowerEdge MX Management and Troubleshooting
A technician replaces a failed Management Module in an MX7000 chassis group. After the technician leaves the site, the administrator reports that the lead chassis is no longer able...
Management Module replacementchassis groupOME-Mcabling verification - Question #86PowerEdge MX Concepts and Architecture
The MDB chassis tub assembly vertical distribution board provides connectivity to which chassis components?
MDBvertical distribution boardcooling fansfabric I/O modules - Question #87PowerEdge MX Concepts and Architecture
Refer to the exhibit. What is shown?
hardware identificationMX5016sstorage sled - Question #88PowerEdge MX Management and Troubleshooting
An administrator has installed the iDRAC Service Module in the OS on a compute sled, they are unable to use its features in the iDRAC web GUI. What is the likely cause of this issu...
iDRAC Service ModuleOS to iDRAC pass-throughiDRAC configurationtroubleshooting - Question #89PowerEdge MX Storage Configuration
A server administrator is deploying a VMware vSphere cluster and configuring High Availability on a PowerEdge MX7000 modular system. Which configuration is required?
VMware vSphereHigh Availabilityenclosure-assigned storagestorage configuration - Question #90PowerEdge MX Management and Troubleshooting
Where in the OME-M Web interface can the Chassis Deployment Wizard be found?
OME-MChassis Deployment Wizardweb interface navigation - Question #91PowerEdge MX Management and Troubleshooting
What can be used as the firmware update source for OME-M within an MX chassis?
firmware updateOME-MDell Update Packageupdate source - Question #92PowerEdge MX Concepts and Architecture
Which MX7000 component is responsible for Fabric Consistency Check?
Fabric Consistency CheckManagement Modulefabric management - Question #93PowerEdge MX Management and Troubleshooting
What types of network shares are supported for hosting the firmware catalog for a PowerEdge MX7000 chassis?
firmware catalognetwork sharesNFSCIFS - Question #94PowerEdge MX Concepts and Architecture
What are the typical ambient inlet temperature readings that ATMOS hardware and fans support?
ATMOSambient temperaturethermal specificationscooling - Question #95PowerEdge MX Management and Troubleshooting
What is a valid option when resetting iDRAC to factory defaults?
iDRACfactory resetuser settingsnetwork settings - Question #96PowerEdge MX Networking Configuration
Which ports will be active in an MX9116n FSE if there are dual-port NICs in all the server sleds?
MX9116nFSEdual-port NICserver-facing ports - Question #97PowerEdge MX Concepts and Architecture
What type of connection is used by QuickSync 2?
QuickSync 2Bluetoothmanagement interface - Question #98PowerEdge MX Networking Configuration
A network administrator must implement a 100 GbE network in their MX7000 chassis group. Which two components satisfy this requirement? (Select 2)
100 GbEMX9116nMX8116nnetwork components - Question #99PowerEdge MX Management and Troubleshooting
Why is the backup lead configuration important in an MCM Group?
MCM Groupbackup leadchassis failoverlead chassis - Question #100PowerEdge MX Networking Configuration
Which I/O module is supported for Fabric B?
Fabric BI/O moduleMX5108nfabric support