D-PEMX-DY-23 Exam Questions
135 real D-PEMX-DY-23 exam questions with expert-verified answers and explanations. Page 3 of 3.
- Question #101PowerEdge MX Concepts and Architecture
What configuration is supported for a fully populated MX740c compute sled?
MX740cmezz cardFabric AFabric B - Question #102PowerEdge MX Management and Troubleshooting
Which protocol(s) does Redfish use?
RedfishJSONODatamanagement protocol - Question #103PowerEdge MX Management and Troubleshooting
A systems administrator must extract log files from an MX7000. The logs cannot be saved locally and must only be stored on a secure file server. Which share protocols can they use...
log extractionCIFSNFSfile share protocols - Question #104PowerEdge MX Networking Configuration
A customer is implementing a clustered three-chassis solution. Which two components are required? (Select 2)
MCMMX9116nMX7116nmulti-chassis cluster - Question #105PowerEdge MX Concepts and Architecture
What is the number of server-facing ports and the bandwidth of each port on the MXG610s? (Choose two.)
MXG610sFibre Channelserver-facing portsbandwidth - Question #106PowerEdge MX Concepts and Architecture
What does OBPAR allow on a PowerEdge MX750c?
OBPARMX750csingle CPU bootreduced frequency - Question #107PowerEdge MX Installation and Configuration
An implementation engineer prepares to install a PowerEdge MX7000. Which serial cable do they use?
serial cableUSB Micro-BMX7000initial installation - Question #108PowerEdge MX Management and Troubleshooting
What feature does OME-M v1.3 provide when replacing the Right Control Panel?
OME-MRight Control Panelchassis configuration persistenceMCM - Question #109PowerEdge MX Storage Configuration
A server administrator wants to configure RAID on drives that are assigned to a compute sled. Which interface can be used to complete the task?
RAIDiDRACstorage assignmentcompute sled - Question #110PowerEdge MX Networking Configuration
What are the correct CLI commands to configure the management IP Address on either the MX9116n or the MX5108n switches running SmartFabric OS10?
CLImanagement IPSmartFabric OS10MX9116n MX5108n - Question #111PowerEdge MX Storage Configuration
A system administrator must assign six of the MX5016s drives to a single MX750c compute node. Which assignment mode accomplishes this task?
MX5016sDrive-Assigned modestorage assignmentMX750c - Question #112PowerEdge MX Concepts and Architecture
What are the components of the control panel of a PowerEdge MX750c sled?
MX750ccontrol panelpower buttonsled components - Question #113PowerEdge MX Management and Troubleshooting
Which feature in OpenManage Mobile can be used to allow the monitoring of a PowerEdge MX7000 chassis?
OpenManage Mobileaugmented realityMX7000 monitoringchassis management - Question #114PowerEdge MX Management and Troubleshooting
An administrator is receiving notifications about insufficient power for a PowerEdge MX7000 chassis. The chassis is fed from two different power grids. What is the best policy to m...
power policygrid redundancyPSUpower management - Question #115PowerEdge MX Concepts and Architecture
Which micro controller-based module allows the Management Module to communicate with all the hardware present in a PowerEdge MX7000 chassis?
FReDManagement Modulemicrocontrollerchassis communication - Question #116PowerEdge MX Management and Troubleshooting
An administrator is asked to install and power-on a new MX740c sled in an MX7000 chassis. The administrator inserts the sled and presses the power button. They notice that the powe...
LED indicatoriDRAC bootMX740cpower button status - Question #117PowerEdge MX Storage Configuration
Which controller option the mapping of an entire MX5016s to multiple compute sleds?
HBA330MX5016smulti-sled mappingstorage controller - Question #118PowerEdge MX Storage Configuration
An administrator is mapping the drives of an MX5016s. The disk must be split in groups among multiple compute sled slots. Which storage configuration must be used?
Drive-Assigned modeMX5016sdrive groupingmulti-sled storage - Question #119PowerEdge MX Management and Troubleshooting
A customer has an MCM group consisting of four MX7000 chassis. They need to take the lead chassis down to perform maintenance. How can the customer ensure that another chassis take...
MCMlead chassisbackup leadfailover - Question #120PowerEdge MX Concepts and Architecture
How are double-width compute sleds on the MX7000 numbered from the front?
double-width sledMX7000sled numberingchassis layout - Question #121PowerEdge MX Installation and Configuration
A technician is doing an initial MX7000 setup and wants to use KVM to configure the MM. KVM is not working. What are the two causes of this issue? (Select 2)
KVM configurationManagement Module setupadapter compatibilityMX7000 initial setup - Question #122PowerEdge MX Networking Configuration
What is a benefit of SmartFabric Services Mode?
SmartFabric Services Modenetworking modesmanagement load balancing - Question #123PowerEdge MX Concepts and Architecture
What is the port configuration of the MX9116n FSE?
MX9116n FSEserver-facing ports25GbE port configuration - Question #124PowerEdge MX Installation and Configuration
An administrator is asked to install and power on a new MX740c sled in a PowerEdge MX7000 chassis. The administrator inserts the sled and presses the power button. The power button...
power LED indicatorsiDRAC boot sequencesled installationMX740c - Question #125PowerEdge MX Storage Configuration
An administrator is connecting two MX840c to an MX5016s. The MX5016s is configured in Enclosure Assigned mode. What should the requirements of this mode be to avoid configuration i...
MX5016sEnclosure Assigned modeHBA330MMZcluster-aware OS - Question #126PowerEdge MX Management and Troubleshooting
The iSM is available under which license(s)?
iDRAC Service ModuleiSM licensingiDRAC ExpressiDRAC Enterprise - Question #127PowerEdge MX Management and Troubleshooting
An administrator is about to perform a firmware update on an MX9116n switch OS 10 from the CLI. The latest OS 10 switch firmware image has been downloaded and their TFTP server is...
MX9116n firmware updateOS 10 CLITFTP firmware upgradeswitch management - Question #128PowerEdge MX Storage Configuration
Which three components are required in an MX7000 chassis to allow multiple compute sleds to share access to the same disks in an MX5016s enclosure? (Select 3)
MX5016s shared storageHBA330MMZcluster-aware OSdrive-assigned storage - Question #129PowerEdge MX Concepts and Architecture
The MX9116n FSE has two single-density QSFP28 port groups, and the default setting for these two ports is 1x 100GbE. What other Ethernet breakout configurations are supported?
MX9116n FSEQSFP28 breakout100GbE uplinksport configuration - Question #130PowerEdge MX Concepts and Architecture
Which two-socket PowerEdge sled can support up to eight E3.s NVMe Gen 5 SSD drives?
MX760cNVMe Gen 5E3.s SSDcompute sled specifications - Question #131PowerEdge MX Concepts and Architecture
Which is an invalid option for the PowerEdge MX7000 control panel?
MX7000 control panelQuickSync 2LCD panelLED panel - Question #132PowerEdge MX Networking Configuration
What is a characteristic of MX7000 networking in Scalable Fabric Mode?
Scalable Fabric ModeMX9116n FSEMX7116n FEMMX5108n compatibility - Question #133PowerEdge MX Networking Configuration
Which VLAN is reserved for internal switch communication?
reserved VLANinternal switch communicationVLAN 4001 - Question #134PowerEdge MX Management and Troubleshooting
A data center team is working on a solution to monitor and manage data center devices from anywhere. Which feature can be configured to perform these tasks?
OpenManage Mobileremote managementdata center monitoringOMM - Question #135PowerEdge MX Networking Configuration
When multiple MX9002m modules are daisy-chained to Top-of-Rack switches, which uplink port can be used for stacking?
MX9002mdaisy-chain stackinguplink portsTop-of-Rack connectivity