RCDD Exam Questions
371 real RCDD exam questions with expert-verified answers and explanations. Page 7 of 8.
- Question #301Special Applications
A telephone facility and an electrical facility are required in a tunnel. To reduce the effects of EMI and eliminate the need for additional shielding of the cables, where would ea...
tunnel installationEMI reductionelectrical separationtelecommunications pathway - Question #302Special Applications
A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (Americans with Disability Act) requ...
ADApay phoneside reachwheelchair accessibility - Question #303Bonding, Grounding and Electrical Protection
Which type of protection for electrical power stations provide isolation against a rise in potential of station ground and also provide drainage protection against longitudinally-...
isolating transformerelectrical protectionground potential riselongitudinal voltage - Question #304Special Applications
One interior TTY must be provided at locations defined as public accommodations with ________ or more pay telephones.
TTYADApay telephonespublic accommodations - Question #305Special Applications
What is the air change requirement for a tunnel of 610 m (2000 ft) long with a diameter of 3.4 m (11 ft)?
tunnel ventilationair change requirementspecial environmentsenvironmental control - Question #306Special Applications
What is the MINIMUM distance from the edge of a pool or other water hazards for a weatherproof enclosure?
weatherproof enclosurewater hazard clearancepool installationoutdoor cabling - Question #307Special Applications
A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (American with Disabilities Act) req...
ADApay phonefront reachwheelchair accessibility - Question #308Special Applications
What does this international symbol stands for?
TTYinternational symboltext telephoneaccessibility signage - Question #309Special Applications
In this future marina layout, what would be the pre-cabling guideline to follow for the terminal A?
marina cablingdistribution cabledock installationpre-cabling guidelines - Question #310ITS Spaces
In an office area, a consultant needs to add the location of a fax machine to the plan. What is the approximated floor area that a fax machine occupies?
fax machinefloor areaspace planningoffice layout - Question #311ITS Spaces
What is the MINIMUM clearance needed between the front of the telephone booth and any wall or fixture for most installations?
telephone boothclearancespace planninginstallation requirements - Question #312Information Transport Systems (ITS) Distribution
You have just finished a design calling for 15 telecommunications outlets. You received word that the owner has increased his requirements by 40%. What size commercial DD (distribu...
distribution devicetelecommunications outletscapacity planningDD sizing - Question #313Information Transport Systems (ITS) Distribution
You are designing a multi-story dwelling and need to place the CTR's. Every floor is not available. What is the alternate spacing for the CTRs?
CTR placementmulti-story dwellingfloor spacingvertical distribution - Question #314Information Transport Systems (ITS) Distribution
You are designing distribution for a seven unit townhouse with in slab conduits. What is the MINIMUM number of 27 mm (1 in) rigid PVC Type 2 or metallic conduit that is required to...
townhouse distributionin-slab conduitPVC conduitunit distribution - Question #315General Cable and Media
You are designing a system requiring the transmission of data. Your system must perform higher than ________ kHz in order to do so.
data transmissionfrequency thresholdbandwidthsignal frequency - Question #316Information Transport Systems (ITS) Distribution
To accommodate telephone, data, CATV, security and multimedia, a MINIMUM of ________ strands of optical fiber auxiliary disconnect outlet (ADO) cable should be provided.
optical fiberADO cablestrand countauxiliary disconnect outlet - Question #317Information Transport Systems (ITS) Distribution
Which service is NOT typical of Grade 1?
Grade 1 serviceresidential cablingmultimediaservice classification - Question #318Bonding, Grounding and Electrical Protection
You must place a cable between 2 equipment locations with separate grounds having a potential difference between them of 2.1 V rms. Which one of the following cables should NOT be...
ground potential differencecable selectionSTPUTP EMI susceptibility - Question #319General Cable and Media
Which characteristic is an advantage of copper based media over optical fiber cable?
copper mediaoptical fiberanalog signalsmedia comparison - Question #320General Cable and Media
A SONET OC-1 channel can carry 672 voice signals and has a data rate of 51.84 Mbps. A SONET OC-48 channel can carry 32,256 voice channels. What MINIMUM data rate is required for th...
SONETOC-48data rate calculationvoice channels - Question #321
Which electrical characteristic is displayed with the correct preferred value?
- Question #322
A reasonable approximation for the signal speed in 100 ohm balanced twisted pair cable is __________, where c is the velocity of light in free space.
- Question #323
Two sinusoidal signals have the same amplitude (A) and the same frequency (f). They differ in phase by 180 degrees. If these two signals are added together, the result is a sinusoi...
- Question #324
The signal at the input to a balanced twisted pair cable is 10 mW. The cable is 1000 feet long and has an attenuation of 1 dB per 100 feet. This cable is connected to the input of...
- Question #325General Cable and Media
If the input signal power to a communication system is 1 W and the output power is 1 mW, the system attenuation is:
attenuationdecibelssignal powerdB calculation - Question #326General Cable and Media
Which of the following correctly lists the lowest frequency band to the highest frequency band?
frequency bandsMF HF VHF UHFspectrumfrequency order - Question #327General Cable and Media
You must place CAT6 cable above a factory floor with automated welding machines and hammer forges. Of the following, what type of shielding would be most effective?
EMI shieldingCAT6metallic conduitindustrial environment - Question #328General Cable and Media
Which is an advantage of stranded conductors over solid conductors?
stranded conductorssolid conductorsflexibilityconductor comparison - Question #329General Cable and Media
Time division multiplexing (TDM) systems are designed to transport ________ between end point systems.
TDMtime division multiplexingdigital signalssignal transport - Question #330Special Applications
Which active DAS component is responsible for coupling input signals from donor systems?
DASbidirectional amplifierdonor systemsignal coupling - Question #331Special Applications
What is at the "root" of a DAS (distributive antenna system)?
DAStransceiverdistributed antenna systemroot component - Question #332Special Applications
You are designing a 4.9 GHz microwave system that is using rectangular waveguide from the transceiver to the inside wall of the shelter and an antenna using elliptical waveguide fr...
microwave waveguideelliptical waveguiderectangular waveguidewaveguide connector - Question #333Special Applications
You are designing multi band UHF police radio and VHF fire radio systems for a municipal office. Because of the closeness of the transmit and receive frequencies, you must ensure t...
DASrepeatertransmit receive filteringmulti-band radio - Question #334Special Applications
Which device supplies the radio signal into a DAS (distributive antenna system)?
DAStransceiverradio signalantenna system - Question #335Special Applications
You are designing a 4.9 GHz microwave system that is using rectangular waveguide from the transceiver to the inside wall of the shelter and an antenna that is to be placed 200 ft u...
microwave systemwaveguideantennatransmission medium - Question #336Special Applications
When considering the DAS, which component acts as a bidirectional antenna?
DASradiating coaxial cablebidirectional antennadistributed antenna - Question #337Special Applications
The propagation and path loss of radio signals in the target environment can be sampled using:
radio propagationpath losssite surveyRF measurement - Question #338Special Applications
Which wireless device should be used to support 3 computers and a printer?
wireless networkingrouterWLANnetwork device - Question #339Emergency, Life Safety and Security
Given the following values, calculate the focal length of the camera lens. - Distance of the camera to the object is 5 m - Vertical field of view is 2 m - Horizontal field of view...
CCTVcamera lensfocal lengthfield of view - Question #340Emergency, Life Safety and Security
What is the MOST important aspect of fire alarm signaling?
fire alarmaudibilitylife safetysignaling - Question #341General Cable and Media
What is the connector of choice for Series 59, Series 6, and Series 11 applications?
F-style connectorcoaxial cableSeries 59Series 6 - Question #342General Cable and Media
What type of fiber optic cable is manufactured to protect individual glass strands and is primarily designed for use inside buildings?
tight-buffered fiberindoor fiberfiber optic cablecable construction - Question #343General Cable and Media
What type of optical fiber is used primarily for outside plant (OSP) applications?
loose-tube fiberoutside plantOSP fiberfiber optic cable - Question #344General Cable and Media
The RJ-45 is now known as the 8P8C style connector, per the Telecommunications Industry Association (TIA) standard. What does the P and C stand for?
8P8C connectorRJ-45TIA standardconnector terminology - Question #345General Cable and Media
What is the frequency rating of an International Organization for Standardization/International Electrotechnical Commission (ISO/IEC) Category 7/Class F cable?
Category 7Class FISO/IECcable frequency rating - Question #346Information Transport Systems (ITS) Distribution
There are three buildings approximately 400 meters apart and the customer wants to use 10 Gig Ethernet. What fiber should be specified for this application?
singlemode fiber10 Gigabit Ethernetcampus backbonefiber selection - Question #347Information Transport Systems (ITS) Distribution
If looking to specify an optical fiber backbone within a building going 275 m (902 ft) between the equipment room (ER) and the telecommunications room (TR), what type of fiber shou...
OM3 laser optimized multimode10GB Ethernetbackbone fiberbuilding cabling - Question #348General Cable and Media
Which of the following is NOT a type of connector for optical fiber?
fiber optic connectorsLCSCS/FTP - Question #349Information Transport Systems (ITS) Distribution
A furniture cluster with 26 requires a MINIMUM of how many multiuser telecommunications outlet assembly (MUTOA)?
MUTOAfurniture clusteropen officeoutlet density - Question #350ITS Spaces
When specifying telecommunications outlet boxes, all of the following should be considered EXCEPT:
telecommunications outlet boxoutlet sizingcable bend radiusinstallation standards