NACE-CIP2-001 Exam Questions
98 real NACE-CIP2-001 exam questions with expert-verified answers and explanations. Page 1 of 2.
- Question #1
The standards defining surface cleanliness achieved by centrifugal blast cleaning are:
- Question #2
You are NACE Level 2 Inspector working on a tank lining job where a mobile centrifugal blast unit is being used to blast the tank floor to a NACE No.1/SSPC SP 5. The Contractor has...
- Question #3
You are a NACE Level 2 in-house inspector working in a shop. Your in-house requires you to perform a sleeve test to test for soluble salts; however the 3rd party NACE Level 3 inspe...
- Question #4
Surface preparation of concrete is performed using:
- Question #5
NACE No.13/ SSPC 6 identifies the use of:
- Question #6
Differences in technique for abrasive blasting concrete versus steel require the operator to:
- Question #7
The Concrete Repair Institute's comparators can be used to assess:
- Question #8
Surface preparation methods for Non-ferrous metals are:
- Question #9
A single component water borne acrylic coating cures by:
- Question #10
When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe:
- Question #11
External coatings applied to buried pipelines are generally tested for:
- Question #12
You are the NACE Inspector on a project where a stationary floating structure is being coated and you notice a self-smoothing anti-fouling coating has been specified. This is not a...
- Question #13
Eddy current DFT gauges are used to measure Dry Film Thickness in which of the following situations:
- Question #14
When measuring the Dry Film Thickness Of liquid coatings applied to galvanized ferrous substrates the most commonly used instrument is the:
- Question #15
The most likely area of failure on a buried external pipeline coating is the:
- Question #16
The best choice of instrument for holiday testing of thick film concrete coatings is:
- Question #17
Thermal Spray coatings provide:
- Question #18
The primary purpose of Fireproofing coatings are to provide:
- Question #19
When using a destructive Paint Inspection Gauge the NACE inspector must:
- Question #20
Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.
- Question #21
When a coating is expected to be exposed to temperatures above 93C (200 F) the best choice would be:
- Question #22
Coating application to concrete substrates is:
- Question #23
Application of Thermal Spray Coatings requires:
- Question #24
You are the NACE Level 2 Inspector on a project where overcoating of galvanized steel is being performed. The specification references SSPC SP 16 as the surface preparation method....
- Question #25
Galvanizing performs best in which of the following exposures:
- Question #26
Ideally, documentation requirements should be defined:
- Question #27
Inspection and Test Plans are provided to:
- Question #28
Inspection and Test plans are developed by referencing:
- Question #29
When completing the Final Inspection report the Inspector should write the report using:
- Question #30
Non-Conformance Reports are designed to:
- Question #31
You are the NACE Level 2 Inspector with the final responsibility to prepare the final report for a very large structural steel shop project which has gone very well. It is due next...
- Question #32
Inspector reports should always be copied to:
- Question #33
As a NACE Level 2 Inspector, NACE clearly indicates that you ate qualified to independently produce final documentation for a shop project.
- Question #34
As a NACE Level 2 Inspector on a field job; prior to submission your documentation should always reviewed and approved by:
- Question #35
You are the NACE Level 2 inspector reviewing the documentation from a NACE Level 1 you notice significant documentation errors. Your FIRST preferred course of action is to:
- Question #36
When ASIN D 3363 is specified the Inspector must:
- Question #37
When performing an adhesion test in accordance with ASTM D 3359 where the Dry Film Thickness is approximately 10 mils, the Inspector should use:
- Question #38
When performing inspection in accordance with ASTM D 4138 the Inspector will use:
- Question #39
NACE International Standards are developed by:
- Question #40
The main reason dehumidification is used during coating operations is to
- Question #41
All of these are advantages of using repair patches EXCEPT
- Question #42
Which surface preparation method uses a dilute acid solution to remove laitance and I roughen the concrete surface?
- Question #43
Linings are used on the interior of pipelines to
- Question #44
Which is used to calibrate a pH meter?
- Question #45
Dehumidification is defined as the removal of moisture vapor from the air to
- Question #46
In powder coatings, when the particles of powder begin to flow but are not fully liquid, they are in what stage?
- Question #47
A reinforced coating is
- Question #48
Measuring methyl ethyl ketone (MEK) resistance of ethyl silicate inorganic zinc-rich primers by solvent rub requires
- Question #49
Corrosion is the reverse process of
- Question #50
Coating surveys may include which steps? Select All That Apply: