NACE-CIP2-001 Exam Questions
98 real NACE-CIP2-001 exam questions with expert-verified answers and explanations. Page 1 of 2.
- Question #1Surface Preparation
The standards defining surface cleanliness achieved by centrifugal blast cleaning are:
centrifugal blast cleaningair blast cleaningsurface cleanliness standardsSSPC - Question #2Inspection Procedures
You are NACE Level 2 Inspector working on a tank lining job where a mobile centrifugal blast unit is being used to blast the tank floor to a NACE No.1/SSPC SP 5. The Contractor has...
centrifugal blast cleaningNACE No.1SSPC SP 5hold point inspection - Question #3Inspection Procedures
You are a NACE Level 2 in-house inspector working in a shop. Your in-house requires you to perform a sleeve test to test for soluble salts; however the 3rd party NACE Level 3 inspe...
soluble salts testingsleeve testsalt smart meterspecification compliance - Question #4Surface Preparation
Surface preparation of concrete is performed using:
concrete surface preparationmodified methodssubstrate differences - Question #5Surface Preparation
NACE No.13/ SSPC 6 identifies the use of:
NACE No.13SSPC SP 6cleaning methodsstandards - Question #6Surface Preparation
Differences in technique for abrasive blasting concrete versus steel require the operator to:
abrasive blasting concreteblast pressurestandoff distancenozzle technique - Question #7Surface Preparation
The Concrete Repair Institute's comparators can be used to assess:
concrete surface profileCSP comparatorsConcrete Repair Institutesurface assessment - Question #8Surface Preparation
Surface preparation methods for Non-ferrous metals are:
non-ferrous metalssurface preparationsubstrate-specific methods - Question #9Curing Mechanisms
A single component water borne acrylic coating cures by:
waterborne acryliccoalescencesingle componentcuring mechanism - Question #10Inspection Procedures
When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe:
hardness testingelastic coatingscold flowcreep - Question #11Coating Failures
External coatings applied to buried pipelines are generally tested for:
buried pipeline coatingscathodic disbondmentexternal coatingspipeline protection - Question #12Coating Application
You are the NACE Inspector on a project where a stationary floating structure is being coated and you notice a self-smoothing anti-fouling coating has been specified. This is not a...
anti-fouling coatingsself-smoothingstationary structurecoating selection - Question #13Inspection Procedures
Eddy current DFT gauges are used to measure Dry Film Thickness in which of the following situations:
eddy current gaugeDFT measurementnon-conductive coatingsconductive substrate - Question #14Inspection Procedures
When measuring the Dry Film Thickness Of liquid coatings applied to galvanized ferrous substrates the most commonly used instrument is the:
eddy current gaugegalvanized substrateDFT measurementinstrument selection - Question #15Coating Failures
The most likely area of failure on a buried external pipeline coating is the:
buried pipelinefield joint coatingcoating failure locationpipeline inspection - Question #16Inspection Procedures
The best choice of instrument for holiday testing of thick film concrete coatings is:
holiday testinghigh voltage DC pulsethick film coatingsconcrete coatings - Question #17Coating Application
Thermal Spray coatings provide:
thermal spray coatingssacrificial protectioncathodic protectionmetalizing - Question #18Coating Application
The primary purpose of Fireproofing coatings are to provide:
fireproofing coatingspassive fire protectionintumescentstructural protection - Question #19Inspection Procedures
When using a destructive Paint Inspection Gauge the NACE inspector must:
paint inspection gaugedestructive DFTTooke gaugehand wheel selection - Question #20Inspection Procedures
Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.
destructive testinginspector authorityspecification complianceNACE Level 2 role - Question #21Coating Application
When a coating is expected to be exposed to temperatures above 93C (200 F) the best choice would be:
high-temperature coatingsinorganic coatingscoating selectiontemperature resistance - Question #22Coating Application
Coating application to concrete substrates is:
concrete substratessubstrate challengescoating applicationsurface porosity - Question #23Coating Application
Application of Thermal Spray Coatings requires:
thermal spray coatingsapplicator skillsspecialized trainingcoating methods - Question #24Surface Preparation
You are the NACE Level 2 Inspector on a project where overcoating of galvanized steel is being performed. The specification references SSPC SP 16 as the surface preparation method....
galvanized steelSSPC SP 16surface preparation alternativeshand tool cleaning - Question #25Corrosion Control Methods
Galvanizing performs best in which of the following exposures:
galvanizingpH rangezinc coatingscorrosion resistance - Question #26Documentation
Ideally, documentation requirements should be defined:
documentation requirementsspecificationproject planningpre-job conference - Question #27Inspection Procedures
Inspection and Test Plans are provided to:
inspection and test planspass/fail criteriainspection sequencingITP purpose - Question #28Inspection Procedures
Inspection and Test plans are developed by referencing:
inspection and test plansTDSstandards and codesITP development - Question #29Documentation
When completing the Final Inspection report the Inspector should write the report using:
final inspection reporttechnical writingdocumentation clarityreport language - Question #30Documentation
Non-Conformance Reports are designed to:
non-conformance reportsNCRspecification compliancequality control - Question #31Documentation
You are the NACE Level 2 Inspector with the final responsibility to prepare the final report for a very large structural steel shop project which has gone very well. It is due next...
missing inspection recordsdocumentation integrityethical reportingfinal report - Question #32Documentation
Inspector reports should always be copied to:
report distributioninspection reportsproject stakeholdersowner - Question #33Documentation
As a NACE Level 2 Inspector, NACE clearly indicates that you ate qualified to independently produce final documentation for a shop project.
NACE Level 2inspector qualificationsshop projectindependent documentation - Question #34Documentation
As a NACE Level 2 Inspector on a field job; prior to submission your documentation should always reviewed and approved by:
NACE Level 2NACE Level 3field documentation approvalinspector hierarchy - Question #35Documentation
You are the NACE Level 2 inspector reviewing the documentation from a NACE Level 1 you notice significant documentation errors. Your FIRST preferred course of action is to:
documentation reviewLevel 1 inspectorerror correctionremedial training - Question #36Inspection Procedures
When ASIN D 3363 is specified the Inspector must:
ASTM D 3363pencil hardness testfilm hardnessinspection recording - Question #37Inspection Procedures
When performing an adhesion test in accordance with ASTM D 3359 where the Dry Film Thickness is approximately 10 mils, the Inspector should use:
ASTM D 3359adhesion testingX-cut methodDFT threshold - Question #38Inspection Procedures
When performing inspection in accordance with ASTM D 4138 the Inspector will use:
ASTM D 4138Tooke gaugedestructive DFT measurementfilm thickness inspection - Question #39Documentation
NACE International Standards are developed by:
NACE standardsstandards developmenttechnical committeesindustry standards - Question #40Coating Application
The main reason dehumidification is used during coating operations is to
dehumidificationenvironmental controlhumiditycoating application conditions - Question #41Coating Application
All of these are advantages of using repair patches EXCEPT
repair patchesabrasion resistancebarrier propertiescoating advantages - Question #42Surface Preparation
Which surface preparation method uses a dilute acid solution to remove laitance and I roughen the concrete surface?
acid etchingconcrete preparationlaitance removaldilute acid - Question #43Corrosion Control Methods
Linings are used on the interior of pipelines to
pipeline liningsinterior protectiontransported productpipeline coatings - Question #44Inspection Procedures
Which is used to calibrate a pH meter?
pH metercalibrationbuffer solutionsurface chemistry - Question #45Coating Application
Dehumidification is defined as the removal of moisture vapor from the air to
dehumidificationmoisture vapordew pointrelative humidity - Question #46Curing Mechanisms
In powder coatings, when the particles of powder begin to flow but are not fully liquid, they are in what stage?
powder coatingsgel stagecure stagesflow stage - Question #47Coating Application
A reinforced coating is
reinforced coatingsabrasion resistanceimpact resistancecoating types - Question #48Inspection Procedures
Measuring methyl ethyl ketone (MEK) resistance of ethyl silicate inorganic zinc-rich primers by solvent rub requires
MEK resistancesolvent rub testinorganic zinc primercure testing - Question #49Corrosion Control Methods
Corrosion is the reverse process of
corrosion definitionsteel manufacturingelectrochemical processcorrosion fundamentals - Question #50Inspection Procedures
Coating surveys may include which steps? Select All That Apply:
coating surveysurvey planningdata collectionperformance evaluation