HP0-S45 Exam Questions
59 real HP0-S45 exam questions with expert-verified answers and explanations. Page 1 of 2.
- Question #1
A customer is using a 3PAR StoreServ storage system attached directly to a BladeSystem Enclosure through Virtual Connect FlexFabric-20/40 FS modules. The customer needs to simplify...
- Question #2
What is a benefit of using 20Gb FlexFabric Converged network adapter (CNA) for the BladeSystems?
- Question #3
Which statement describes how integrators use HP OneView to manage firmware on managed enclosures and servers?
- Question #4
How does Secure Boot protect against unauthorized operating systems and malware attacks?
- Question #5
A company needs a solution Tor monitoring and diagnosing issues with devices in its data center. The company has the following requirements for the solution: - It monitors its HP P...
- Question #7
Which resource can a server integrator use to verify whether VMware vSphere ESXi 5.5 U2 is supported on an up BL460c Gen9 server?
- Question #8
An integrator needs to upgrade the BIOS and Smart Array controller firmware on an HP ProLiant Gen9 series server. The server has no operating system installed and the customer site...
- Question #9
A server integrator needs to install the maximum amount of memory in a new BL460c Gen9 server Which type of memory should the integrator install?
- Question #10
Which HP software-defined platform automates management of HP servers, storage, and other HP converged Infrastructure using RESTful API?
- Question #11
A customer with HP ProLiant DL360 Gen9 servers needs to combine Fibre Channel over Ethernet (FCoE) with their LAN traffic over a single 10Gbe connection. Which FlexFabric adapter m...
- Question #12
An integrator needs to deploy images to multiple HP ProLiant DL380 Gen9 servers at the same time with multicast PXE. Which feature should the integrator enable?
- Question #14
What is the maximum number of processor cores on an HP ProLiant Gen9 server?
- Question #15
An integrator is installing HP ProLiant DL380 Gen9 rack based servers into a customer's existing racks The integrator verifies with the customer that the ambient temperature readin...
- Question #16
A system integrator installed an operating system on an HP ProLiant Gen9 Server. Which operating system can be used with UEFI Boot Mode?
- Question #17
A customer is planning where to locate their servers in the data center and how to manage and monitor power consumption. They have purchased HP iPDU units for the cabinets where HP...
- Question #18
Which is an approprate use of the HP OneView Dashboard?
- Question #19
What should the integrator use to back up HP OneVlew?
- Question #20
An integrator is installing an HP ProLiant BL460C Gen9 server into device bay 13 of an HP C700O BladeSystem enclosure. The integrator needs to access the UEFI System Utilities on t...
- Question #21
A server integrator has made a change to the Hyper-Threading configuration in the BIOS on a single HP BL460c Gen9 Server Blade in the VMware environment. Which tool should the inte...
- Question #22
A customer has two HP c7000 BladeSystem Enclosures equipped with Virtual Connect FlexFabric 10Gb/24-Port interconnect modules and is managing this environment with HP OneView. Both...
- Question #23
An integrator needs to add an HP c70OO BladeSystem Enclosure to HP OneView Which information should the integrator collect tor this purpose?
- Question #24
A customer has an HP ProLiant DL3SO Gen9 server that has no hard drives or SD card. The customer needs to install a virtual nation Operating System on this server. Which method sho...
- Question #25
A server integrator has selected Virtual Connect Flex-10/10D modules as interconnect modules for HP BladeSystem Enclosures Blade servers wilt use Fibre Channel over Ethernet (FCoE)...
- Question #26
An integrator needs to change the HP Smart Array P244br controller power mode to optimal settings based on a configuration with minimal performance impact on the server. How should...
- Question #27
A customer with ProLiant Gen9 based servers needs to add external storage to some of the servers. Which component should the integrator recommend?
- Question #28
A customer needs eight SAS drives installed in a RAID 10 configuration in their new HP ProLiant DL380 Gen9 server using the Dynamic Smart Array B140i Controller embedded into the s...
- Question #29
An integrator needs to install an operating system on an HP ProLiant Gen9-series server using me HP Dynamic Smart Array B140i Controller. What should the integrator do?
- Question #30
An integrator needs to install Windows Server 2012 R2 on 6 HP ProLiant BL460C Gen9 servers. The servers will be part or an SQL cluster and must be configured identically. The integ...
- Question #31
Which pre-boot environment allows an Integrator to update firmware with a fwupdate command?
- Question #32
An integrator is installing an HP ProLiant DL380 Gen9 server with an H240ar controller installed. The integrator needs to install a total of 24 SFF Drives. Which additional task mu...
- Question #33
A customer needs to deploy a legacy operating system on an HP DL380 Gen9 Server. The integrator sets the BIOS to support Legacy BIOS Boot Mode. When the integrator attempts to inst...
- Question #34
How do HP Intelligent Power Distribution Units (iPDUs) help server integrators?
- Question #35
Power was lost to an HP ProLiant DL380 Gen3 Server. The system ROM is now corrupted and the server can no longer boot. What should the integrator do first to correct this problem?
- Question #36
How should the server integrator use HP OneView to standardize settings for HP BladeSystem Enclosure interconnect modules?
- Question #37
An administrator deployed HP OneView to the ESXi server managed by the vCenter Server. During the initial configuration, the administrator configured the wrong IP address and is un...
- Question #38
An Integrator needs to update server software and firmware for more than 300 servers running Windows Server 2008 and Windows Server 2012 R2. Which tool should the integrator use to...
- Question #39
Which internal drive components does HP Secure Encryption protect?
- Question #40
A customer needs their HP ProLiant DL380. Gen9 server to automatically report hardware failures to the HP Support Center. Which tool should an integrator select to enable automatic...
- Question #41
An integrator needs to deploy an HP OneView appliance to the ESXi Server managed by the vCenter Server. Which tool can the integrator use to access the vCenter Server?
- Question #42
A customer needs to implement HP OneView to manage a data center based on Gen9 servers running Windows OpenStack, and VMware. Which other component can the integrator implement in...
- Question #43
A customer has an HP ProLiant OL380 Gen9 server with a Smart Array P440ar controller. The customer needs to add another internal drive cage and create a RAID set using all internal...
- Question #44
A customer needs a Smart Array controller that will provide basic RAID protection, increased performance, and HP secure Encryption in HP ProLiant Gen9 servers. Which Smart Array co...
- Question #46
A customer is using HP ROM Configuration Utility (HPRCU) to script the BIOS configuration of their Gen8 servers. The customer is now moving to Gen9 servers configured with UEFI. Wh...
- Question #47
What is required to successfully move from HP SIM to HP OneView?
- Question #48
An integrator is preparing tor 3n HP OneView installation. Which software component needs to be installed at the customer site before the integrator can perform the installation?
- Question #49
A customer has added a storage blade to their current c7000 Bladesystem Enclosure, however me external storage is not visible from the adjacent HP ProLiant BL460c Gen9 server blade...
- Question #50
A customer has an HP ProLiant DL380 Gen9 server with one processor that has a large RAID 5 SAS Array configured on a P440ar storage controller with a hot spare. During the rebuild...
- Question #51
Under which circumstance will a server Integrator need to access the HP Untried Extensible Firmware Interface (UEFI)?
- Question #53
A customer has a DL380 Gen9 Server using a Smart SAS HBA controller H240ar. The customer needs to add two SFF disk drives to the rear of the server. Which component is required?
- Question #54
What is a benefit of advanced memory protection on HP ProLiant BL460c Gcn9 servers?