SG0-001 Exam Questions
609 real SG0-001 exam questions with expert-verified answers and explanations. Page 9 of 13.
- Question #401Storage Functionality
Which of the following terms describes the scenario in a storage system where one or more LUNs have a process run against them to find identical content to reduce the consumed stor...
deduplicationstorage optimizationLUNspost-process - Question #402Storage Functionality
Which of the following is true of both deduplication and compression?
deduplicationcompressionstorage optimizationspace efficiency - Question #403Storage Connectivity
Which of the following terms describes the situation where a single HBA can represent many World Wide Ports Names on a fabric to give a unique World Wide Port name to a number of h...
NPIVFibre ChannelWWPNHBA virtualization - Question #404Storage Management
A storage administrator has provisioned a LUN from a storage system to a new host and created the appropriate zones. The server administrator now states that the host cannot see th...
LUN maskingstorage provisioningtroubleshootinghost access - Question #405Storage Connectivity
A FC SAN environment has a single director for each fabric. The SAN administrator wants to separate tape and disk traffic in a very secure manner. Which of the following virtualiza...
VSANsFibre ChannelSAN segmentationnetwork security - Question #406Storage Components
When comparing 7,200 RPM disk drives to 15,000 RPM disk drives, the 15,000 RPM disk drives will have:
HDD performanceRPMlatencydisk components - Question #407Storage Management
A storage administrator is troubleshooting a higher than normal failure rate of LTO tapes. The administrator has noticed that most of the failed tapes are associated with hosts bac...
LTO tapestape backupshoe-shiningtroubleshooting - Question #408Storage Functionality
Which of the following backup methods would take the LEAST amount of time to complete?
backup methodsincremental backupbackup efficiency - Question #409Storage Functionality
Which of the following describes a differential backup?
differential backupbackup types - Question #410Storage Components
A disk cylinder refers to which of the following?
disk architecturecylinderHDD components - Question #411Storage Implementation
The database group at a highly successful Internet retailer has requested 1TB of space for organic growth in their online order database. The storage array is configured in a RAID...
RAID 5FC drivesdatabase storagedrive selection - Question #412Storage Management
Which of the following would be the appropriate technology an administrator would use to provision the desired amount of space to a server, while only the utilized disk space is co...
thin provisioningvirtual provisioningstorage efficiencyLUN provisioning - Question #413Storage Functionality
Which of the following can provide the capability of mirroring a LUN between two storage arrays?
SAN virtualizationLUN mirroringdata replication - Question #414Storage Implementation
When setting up queue depths in the below environment parameters: - A storage device's port queue depth setting is set to 160 - They would like to assign 4 host HBAs to each port W...
queue depthHBA configurationperformance tuningstorage connectivity - Question #415Storage Management
Which of the following is the BEST time to schedule a backup to run on the SAN?
backup schedulingSAN operationsresource utilizationbest practices - Question #416Storage Components
Which of the following drives provides the FASTEST throughput?
SSDdrive performancethroughputstorage components - Question #417Storage Functionality
Which of the following backup restore methods takes the LONGEST?
backup restoreincremental backupbackup types - Question #418Storage Components
Which of the following devices are considered WORM devices? (Select TWO).
WORMCD-ROMDVD-ROMstorage media - Question #419Storage Implementation
Which of the following is a common practice with regards to hot spares on a storage array utilizing RAID?
hot sparesRAIDstorage arrayhigh availability - Question #420Storage Connectivity
A dual controller head storage array is zoned to two different fabrics. How should the administrator cable up the storage array to ensure redundancy and resiliency?
SAN cablingredundancyhigh availabilitydual controllers - Question #421Storage Connectivity
Which of the following topologies is capable of handling up to 127 devices?
arbitrated loopnetwork topologydevice limits - Question #422Storage Connectivity
Which of the following can be used to optimize the bandwidth between connected switches?
trunkingbandwidth optimizationinter-switch links - Question #423Storage Functionality
Which of the following is the BEST option to make a complete point-in-time copy?
clonepoint-in-time copydata protection - Question #424Storage Management
An administrator is responsible for setting up monitoring of multi-vendor SANs. Which protocol will allow for secure, threshold-based trap alerting?
SNMPv3SAN monitoringalerting protocolsmulti-vendor management - Question #425Storage Functionality
Which of the following could be a result of a failed drive in a properly configured storage array? (Select TWO).
drive failurestorage array redundancyalerting - Question #426Storage Connectivity
After working for the past six months, a server no longer can see its storage. An administrator is aware that a new storage array was installed last night and was made available to...
troubleshootingSAN connectivityzoningstorage visibility - Question #427Storage Functionality
Which of the following replication techniques will protect data from a site failure?
remote clonedata replicationdisaster recoverysite failure protection - Question #428Storage Components
Which of the following is an advantage of moving from a small RAID 5 set to a large RAID 5 set?
RAID 5performance optimizationRAID configuration - Question #429Storage Management
The process of replacing a file with a pointer when an identical file is found in more than one location on the host, is which of the following?
single instance storagedata deduplicationstorage optimization - Question #430Storage Components
Which of the following disk drives can be installed into SAS disk enclosures? (Select TWO).
SAS drivesSATA drivesdrive compatibilitydisk enclosures - Question #431Storage Management
Which of the following is LVM used for when mirroring or striping?
LVMlogical volumemirroringstriping - Question #432Storage Management
A database is designed to auto-extend its table spaces as data is ingested. Which of following technologies would help optimize storage utilization ratios?
thin provisioningstorage optimizationdatabase storagecapacity management - Question #433Storage Connectivity
A large number of intermittent SCSI errors are suddenly appearing in a host's log, but the storage array has been verified as fully operational. The link lights on the SAN switch c...
troubleshootingSCSI errorsSAN connectivityport error counters - Question #434Storage Functionality
Which of the following can be a benefit of Content Addressable Storage?
Content Addressable Storagesingle instance storagedata integrity - Question #435Storage Management
Which of the following technologies can help optimize capacity utilization when storing many versions of a large file with few changes in each revision of the file?
block-level deduplicationcapacity optimizationversioningdata storage - Question #436Storage Components
In case of a power outage, to protect the write cache the controller uses an embedded battery system to keep the cache memory viable. Which of the following terms describes this be...
battery backed cachewrite cache protectionpower outage protectionstorage controller - Question #437Storage Connectivity
An administrator is installing a new cable plant in a datacenter. The administrator plans on using 50 micron multi-mode cabling that is in stock. Which of the following needs to be...
multi-mode fiberfiber optic cablingdatacenter cablingdistance limitations - Question #438Storage Management
A SAN administrator has been advised that access to manage storage and switching devices has been changed to a different VLAN for security reasons. The administrator cannot log int...
troubleshootingmanagement accessVLANsfirewall settings - Question #439Storage Connectivity
FCoE achieves higher performance with the use of which of the following?
FCoEperformance optimizationjumbo framesnetwork protocols - Question #440Storage Implementation
Which of the following must a technician create to establish a session between a NAS device and a server?
NASfile systemnetwork sharesstorage access - Question #441Storage Functionality
Given a limited amount of storage, a technician wants to maximize capacity for multiple hosts and utilization efficiency. Which of the following would BEST achieve this?
thin provisioningstorage efficiencycapacity management - Question #442Storage Connectivity
Which of the following is an advantage of an iSCSI SAN over a FC SAN?
iSCSI SANFC SANstorage cost efficiency - Question #443Storage Components
Which of the following is the MAXIMUM storage capacity of a dual-layer Blu-Ray disk?
Blu-Raystorage capacityoptical media - Question #444Storage Connectivity
An administrator has built two storage arrays for a BCDR solution. Each array is in a different datacenter and each datacenter has its own SAN. The SANs will be directly connected...
fiber optic cablingsingle-mode fiberSAN connectivitylong-wave SFP - Question #445Storage Connectivity
An administrator has just installed a brand new HBA into a host and needs to connect that host to the SAN. Which of the following connector types should be used?
HBASAN connectivityfiber optic connectorsLC connector - Question #446Storage Management
An administrator is troubleshooting a server that is intermittently losing access to its disk down a single path. The connected switch port has a lot of errors. The host HBA has ap...
SAN troubleshootingphysical connectivityfiber optic issuesLC connector - Question #447Storage Management
In an FCIP environment where data replication is occurring between two FC SANs communication errors are becoming persistent, and occasionally the link drops. Which of the following...
FCIPSAN troubleshootingnetwork utilitiesfcping - Question #448Storage Connectivity
Which of the following distances is supported for 50 micron multimode cable for 4 Gb/s Fibre Channel?
Fibre Channelmultimode fibercabling distancesSAN connectivity - Question #449Storage Management
A server administrator reports a lot of SCSI transport errors and retries on one server. Which of the following methods, on the Fibre Channel switch, would display these errors?
Fibre Channel troubleshootingswitch diagnosticsport error countersSCSI errors - Question #450Storage Functionality
A company has two data centers, 25 kilometers (15.5 miles) apart. Data is replicated from the primary to the secondary site using a method that commits data to storage at both site...
synchronous replicationremote replicationdata protectionBCDR