HP2-T26 Exam Questions
245 real HP2-T26 exam questions with expert-verified answers and explanations. Page 1 of 5.
- Question #1
Which memory configuration types are supported in the Gen8 ProLiant Blade servers? (Select two.)
- Question #2
Your customer has a business critical HP BladeSystem enclosure and wants to protect it with additional service coverage. The company's requirements are 24x7 and functionality must...
- Question #3
After replacement of a BL460c G7 system board, the server is unable to connect to an external shared storage through the SAS interface. Other similar servers in the same enclosure...
- Question #4
You installed an FC HBA in mezzanine slot 2 of a BL460c G6 in a c7000 enclosure. In which interconnect bays should the FC interconnect be installed?
- Question #5
HP HP2-T26 Exam How many half-height blades can you install in the enclosure shown?
- Question #6
Where can you verify the status of an external DVD-ROM drive in a c7000 enclosure?
- Question #7
You are installing a new HP BladeSystem c7000 enclosure. The customer wants to configure the iLO and interconnect IPs so that they are automatically maintained during a hardware sw...
- Question #8
A customer is installing a new drive in a BL460c Gen8. None of the LEDs on the drive are lit. What is a possible cause?
- Question #9
What should you use to check the overall health status of all the BL460c Gen8 servers you recently installed in a c7000 enclosure?
- Question #10
Which step must be done after the system board is replaced on a BL460C G6?
- Question #11
A customer has a c7000 enclosure that is fully populated with BL680c blades. Two months after the initial installation, the rack initiates a thermal shutdown. When diagnosing the p...
- Question #12
You need to capture the configuration and support dump of several Virtual Connect domains. Which tool can be used to perform this action from a central system?
- Question #13
How does humidity affect a data center? (Select two.)
- Question #14
Both the c3000 and c7000 chassis have a capacity for a maximum of six power supplies. Which feature does the c3000 have that differentiates it?
- Question #15
After executing a troubleshooting plan, which tools may provide indications of a successful remedy in step 5 of the 6-step HP Troubleshooting Methodology? (Select two.)
- Question #16
Step 5 of the 6-Step HP Troubleshooting Methodology requires verification that the repair was successful. Which authorized tool provides this information for ProLiant servers?
- Question #17
What should you do to replace a defective Standby Onboard Administrator (OA) in a c7000 enclosure?
- Question #18
A customer is experiencing intermittent storage connectivity issues in their BladeSystem environment. After collecting the log files from the external storage system and the interc...
- Question #19
A system engineer wants to replace the c3000 BladeSystem Insight Display. What must be done before the engineer can remove it? (Select two.)
- Question #20
You want to connect to a ProLiant Server Blade that has the iLO port available. What must you do to connect a laptop for a direct connection to the Onboard Administrator?
- Question #21
Which CLI commands can be used to determine if networking has been configured properly in Windows? (Select two.)
- Question #22
What happens during a Virtual Connect configuration restore?
- Question #23
HP HP2-T26 Exam When performing a backup of a Virtual Connect configuration, where is the configuration file saved?
- Question #25
Which information can the user access from an HP Array Diagnostics Utility (ADU) report? (Select two.)
- Question #27
What provides information on the software inventory of a server and available updates?
- Question #28
HP HP2-T26 Exam A c7000 connected to an MDS600 is not working as expected. Several times a day, blades lose connectivity to their assigned disks. Your manager asks you to develop a...
- Question #29
A customer is experiencing drive encryption issues with a BL490c Server Blade running Microsoft Windows Server. The Trusted Platform Module (TPM) is suspected as the cause. What mu...
- Question #30
After the replacement of an HP StorageWorks Ultrium Tape Blade, the new unit should be tested. What is the recommended diagnostic and support tool for c-Class tape blades?
- Question #31
Which action should you take first when the Insight Display goes dark?
- Question #32
Refer to the exhibit below. From the main menu shown in the exhibit, which menu should you select HP HP2-T26 Exam from Insight Display to check the Onboard Administrator Service IP...
- Question #33
Which capability does Intel QuickPath technology provide?
- Question #34
Which method should you use to remove a jammed cartridge from a tape blade?
- Question #35
Which HP c-Class server blade series only supports non hot-plug SATA drives?
- Question #36
How many processor sockets does the HP BL870c c-Class Integrity Server Blade have?
- Question #37
A rack with a c7000 is to be relocated to a remote location. What should be used when moving the rack to ensure no damage will occur to the enclosure?
- Question #38
Which mezzanine card is compatible with the HP ProCurve 6120XG interconnect?
- Question #39
When a customer is using a StorageWorks 3Gb SAS BL Switch in the c7000 enclosure, what can be connected?
- Question #40
What is the default ASR timer value after the HP Server Health driver is loaded? HP HP2-T26 Exam
- Question #41
When installing half-height c-Class server blades in a c3000 rack enclosure, what is the recommended sequence for installing them into the server bays when viewed from the front of...
- Question #42
You replace a fully buffered DIMM and want to verify it by running the ROM-Based Memory Test. Where can you access this test?
- Question #43
If time is critical and all memory tests in the HP Insight Diagnostics Offline Edition cannot be run, which memory tests should be run? (Select two.)
- Question #44
What do you use to access RBSU to retrieve information?
- Question #45
A BL490c G6 processor has been replaced. The customer wants the new processor to be tested for several hours before placing the server blade back in service. In order to accomplish...
- Question #46
Where can you find video clips of Field Replaceable Unit (FRU) removal/replacement procedures?
- Question #47
Which statements are true about Online Spare memory banks? (Select two.)
- Question #48
A customer installs HP Network Configuration Utility on their ProLiant server and wants to see if the TOE and RSS features have been enabled for the NICs. Which file under c:\progr...
- Question #49
A server blade has a memory error. All the LEDs in all the banks are illuminated. What should you do first to address this issue?
- Question #50
A customer has an SB40c paired with a full height blade. The blade cannot access the SB40c storage. Which component in the blade may need to be replaced?
- Question #51
What should be done after a repair has been validated?
- Question #52
When you try and boot a previously installed operating system, a BL495c G6 Server Blade freezes. What is the first step you should take when troubleshooting this problem?