H31-341_V2.5 Exam Questions
997 real H31-341_V2.5 exam questions with expert-verified answers and explanations. Page 18 of 20.
- Question #851
When the cross-connect board is configured with 1+1 hot backup, under normal switching conditions, the replacement of the cross-connect clock board will not affect the packet servi...
- Question #852
The subnet mask of 255.255.255.248 is calculated according to the calculation formula. It can accommodate 23 devices, that is, 8 devices.
- Question #853
The OTN electrical layer SM, PM, and TCMi overheads all contain a 1-byte BIP8 field: they monitor different frame structures.
- Question #854
For the relay-type OUT, all alarms of the SM segment are terminated at the local station and will not be sent downstream (except OTUk LOF inserted downward into ODUk PM_AIS). Other...
- Question #855
SF is a signal failure event and SD is a signal degradation event. Both SF and SD events are conditions for triggering protection switching; however, whether SD time is used as a c...
- Question #856
When using a script to back up U2000 data, the backup speed is very fast because the backup file is small.
- Question #857
For Huawei equipment, the NODE ID is the unique identifier of the intelligent network element on the control plane. After the network is configured with intelligent services, the N...
- Question #858
MPLS APS is a network protection mechanism, which implements service switching through the detection function of MPLS OAM.
- Question #859
When the circuit board detects the B1 byte and finds that the bit error rate of the signal in the regeneration section exceeds 10-3, it reports a B1_SD alarm.
- Question #860
GFP-F is a packet data (PDU)-oriented processing mode. It encapsulates the entire packet data into the GFP load information area, does not make any changes to the encapsulated data...
- Question #861
For ODUk SNCP protection, if the pass-through station is an electrical relay station, it is recommended to configure the SNCP type as SNC/I when configuring protection.
- Question #862
The LER in the MPLS network is a kind of LSR located at the edge of the network.
- Question #863
SOM (Smart Optical Management) is only an optical tube system, which can realize centralized configuration of optical and electrical layer parameters.
- Question #864
Line boards selectively receive service in case of SNCP. So SNCP can protect the service on the line.
- Question #865
According to the formula "ODUk rate=239/(239-k)*STM-N frame rate", the ODU4 rate is equal to 239/235xSTM-N frame rate.
- Question #866
After subnetting, network traffic can be reduced, network performance can be improved, and management can be simplified.
- Question #867
Inter-board crossover mainly includes two application scenarios: client-side service drop-in and WDM-side service pass-through.
- Question #868
When ODUk SNCP protection is configured, ordinary WDM services can be converted to SNCP services, but SNCP services cannot be converted to ordinary WDM services.
- Question #869
NG WDN ASON network can provide services of different service levels according to different levels of customer needs. The electrical layer ASON at the WDM service layer supports th...
- Question #870
The optical amplification unit can make up for the line loss and increase the transmission distance, and the system transmission distance can be extended to infinity through multi-...
- Question #871
The SDH network will not change the structure and rate of the client-side signal.
- Question #872
The collection and storage of on-site data includes regular collection when the equipment is in normal operation and collection when the equipment fails the network. Generally, bef...
- Question #873
The OTN circuit board of OSN 1800V (such as: ND2) can reflect the high or low optical power of the receiving end at the local end through the status of the indicator light on the p...
- Question #874
When the ACT indicator of the SDH board is off, it means that the board has a hardware failure and cannot be used.
- Question #875
When VC-4 and AU-4, VC-12 and TU-12 have no frequency difference and phase difference, the value of AU-PTR is 522 and the value of TU-PTR is 70
- Question #876
The transmitting light source in the integrated DWDM system must strictly abide by the G.693 optical port specification.
- Question #877
The key to NG WDM system fault location is to accurately locate the fault to a single station.
- Question #878
In the process of configuring E-LAN, the "MAC address" learning mode can be set to SVL and IML. SVL is independent VLAN learning, /VL is shared VLAN learning.
- Question #879
RSOH, MSOH, HPOH and LPOH realize the monitoring function in descending order of the monitoring range.
- Question #880
OSN 3500 branch service has strong up and down capabilities: there are 16 branch outlet slots, 504 2M, 32 E4, 117 E3/DS3, and 132 STW-1e to provide STM-1/4/16/ 64 group rate
- Question #881
OSN 8800 equipment adopts fan redundancy protection. When any fan in the fan box is broken, the system can still run normally for a long time.
- Question #882
SDH can transmit any rate signal in the SDH system after being packaged.
- Question #883
TTL. Time to live is mainly used to limit the number of hops that IP data packets can pass through routers in the network. For example, TTL=1 means that the data packet can only be...
- Question #884
The OptiX NG WDM device only supports the global label control, and the size of the label control is 32768.
- Question #885
When deleting a discrete service, deactivate it first, and check the alarm at this time. If there is no PS, TU-AIS and other alarms, it means that it is a garbage service. If there...
- Question #886
MAC loopback and PHY loopback are used for fault location. When the MAC loopback is set to in loop, the PHY loopback can be set according to the actual situation.
- Question #887
MPLS technology introduces the concept of connection-oriented label switching on the connectionless IP network, and integrates IP technology and ATM label switching technology.
- Question #888
MPLS is not a service or application. It is actually a tunneling technology.
- Question #889
The optical and electronic racks of the OSN 9800 equipment communicate through master-slave sub-rack cascading, and are connected through the GE1/2 ports on the CTU single board.
- Question #890
FXS and FXO are the names of ports used by analog telephone lines. FXO and FXS are always used in pairs.
- Question #891
According to the recommendation of ITUT, the requirement that the MSP switching time should be within 50ms is conditional. For example, the number of network elements on the entire...
- Question #892
Through the northbound interface, the U2000 can be flexibly interconnected with different third- party network management systems to provide physical storage and alarm data informa...
- Question #893
In the extended SSM ring network dual BITS clock protection scenario, in order to prevent the clock signal from forming a loop, you only need to configure the external clock source...
- Question #894
The OSN 1800 V subrack can support the AC power solution, and the power supply board is APIU.
- Question #895
For MSTP equipment, the service layer path is the path that exists on the network management side, and the client layer path is the path that exists on the network element side.
- Question #896
There is a slot mapping relationship between the OSN3500 processing board and the interface board. The processing board in slot 1 maps to the interface boards in slots 19-20.
- Question #897
1510nm optical monitoring channel can be effectively amplified by EDFA.
- Question #898
The levels of forced switching, fiber cut switching, manual switching, and practice switching are arranged from high to low.
- Question #899
Physical port: also known as MAC port. It is the external port of the single board.
- Question #900