E20-616 Exam Questions
235 real E20-616 exam questions with expert-verified answers and explanations. Page 1 of 5.
- Question #1
Which set of VMAX interface types support software compression with SRDF?
- Question #2
What is the maximum number of High Density Storage bays that can be configured in a VMAX 40k?
- Question #3
Which two System Bays use the same component layout when fully populated?
- Question #4
How many Management Modules are installed in a 6 bay VMAX 10K (987)?
- Question #5
What is the maximum DAE count for Engine 1 of a VMAX 10K (987) dense configuration?
- Question #6
When upgrading an existing I/O module to a DARE I/O module, what impact will it have on the VMAX 40K system?
- Question #7
Which action needs to be taken if the Backend Cabling Verification fails after a Data Center relocation?
- Question #8
While running the Backend Cabling Verification script, the LEDs do not match the SymmWin graphic. It halts with a message that there is a cabling error and advises moving cables. W...
- Question #9
What is one of the activities of the VMAX Management Module?
- Question #10
Which component is used to connect the Service Processor to the Engines?
- Question #11
What is a characteristic of VMAX 20K Power Vault Hypers (PVDs)?
- Question #12
What is a characteristic of VMAX 40K Power Vault Hypers (PVDs)?
- Question #13
What is the maximum amount of cache available in a VMAX 40K Engine using only 32GB DIMM?
- Question #14
A CE is dispatched to perform an FCO replacing multiple SPS. After logging into a Symmetrix VMAX 40K running Enginuity 5876.159.102 Simplified SymmWin is automatically launched. Ho...
- Question #15
A SIB replacement is required on VMAX. The customer asks what the impact will be on the front- end ports. What should your response be?
- Question #16
SPS 2A in Storage Bay 1A has a life of 300 seconds. How many power failures can it withstand?
- Question #17
You are using the SymmWin simulator to test an upgrade. What is required for a successful test?
- Question #18
Which procedure wizard option would you use to validate the configuration before it is loaded into the Symmetrix system?
- Question #19
You are configuring a VMAX 40K for an Open Sytems host. Where can you find the current VMAX 40K Simple Support Matrix?
- Question #20
You are asked to add SRDF to a VMAX 20K that is currently at 5876. After you install Enginuity 5876 on your desktop, how should you upgrade the IMPL.BIN?
- Question #21
What is an advantage of using the Hosts tab when creating an open system configuration with SymmWin?
- Question #22
What is required to create Dynamic SRDF Groups?
- Question #23
You are reviewing a VMAX configuration and find 4 TDAT devices. Which type of Symmetrix VMAX feature is configured?
- Question #24
You are reviewing a VMAX configuration and find 4 Diskless devices. Which type of Symmetrix VMAX feature is configured?
- Question #25
A customer is currently running a z/OS 1.10 Mainframe Operating System and has 3390-3 and 3390-9 devices configured. They would like to increase the size of their devices. What is...
- Question #26
Which statement best describes a Mainframe LPAR?
- Question #27
Which VMAX Models Support CKD Virtual Provisioning?
- Question #28
Customer creates 30 DRX devices on a source VMAX and 60 DRX devices on a target VMAX. After that, they execute the SRDF Compare Tool to check any inconsistency; but the report is e...
- Question #29
In a RDF Compare Report, which condition represents the lowercase letter "s" for mismatched configurations?
- Question #30
You are configuring SRDF in a VMAX 10K for a customer. Which type of SRDF Directors can you use in the SymmWin Directors Map?
- Question #31
You are configuring SRDF on a single bay VMAX 10K. Which Director slices can you select for the Fiber Channel RF links while maintaining redundancy?
- Question #32
Which Enginuity supports IBM iSeries emulation D910?
- Question #33
What is the Best Practice when configuring Fast VP volumes?
- Question #34
Where in SymmWin can the Secure Erase feature be enabled or disabled?
- Question #35
What is a SymmWin Best Practice when configuring disk drives?
- Question #36
What is the EMC recommended best practice when configuring a volume on a VMAX 10K?
- Question #37
Which RAID 6 configuration is supported by Symmetrix?
- Question #38
You are in a configuration meeting with a new customer to discuss the different types of data protection. Which type is recommended if customer's data availability is more importan...
- Question #39
A banking customer reported performance a issue in their DB server, which is connected to a dedicated FA on a VMAX array. After initial analysis, a bottleneck was found on the FA l...
- Question #40
What is a SymmWin Best Practice when configuring disk drives?
- Question #41
On a VMAX 10K, what is a Power Vault requirement?
- Question #42
Where are the daisy chained DAEs for engine 3 located in a fully populated VMAX 10K (987) dense configuration?
- Question #43
Refer to the exhibit. What is the VMAX component illustrated as '8'?
- Question #44
Refer to the Exhibit. What is the VMAX 10K component illustrated as 'A'?
- Question #45
Which disk types can be used in a Symmetrix VMAX?
- Question #46
A customer plans to upgrade an existing four-Engine Symmetrix VMAX 40K to a five-Engine VMAX 40K. How many new vault devices will be added as a result of this upgrade?
- Question #47
Refer to the Exhibit. What is the VMAX 10K component illustrated as 'B'?
- Question #48
Refer to the exhibit. Which array houses the R1 devices, and in which status are the devices?
- Question #49
Refer to the Exhibit. You are implementing ESRS. Into which Ethernet port do you plug the IP cable?
- Question #50
Refer to the Exhibit. You are Enabling SMC on the Service Processor. Into which Ethernet port do you plug the IP cable?