- Question #54
Your customer is serially connected using PPP from a management station to an array. What is the maximum baud rate that can be used for a dial-up networking environment?
- Question #55
Which type of session is required to reset the domain security to an established storage domain?
- Question #56
Your customer with a RAID 6 environment experiences data loss due to disk drive issues. Which type of fault is this considered?
- Question #57
Where would a Customer Engineer find documentation explaining Test and Acceptance Criteria (TAC)?
- Question #58
Your customer has experienced problems viewing target LUNs from one of their HP-UX hosts. The Support Center has requested a data collection. Which EMC supplied utility should be r...
- Question #59
Click the Exhibit Button. On the CX4-960 power cabling diagram, which does "b" depict?
- Question #60
Which report needs to be run before any maintenance is performed on a CX4 series CLARiiON?
- Question #61
How many BE ports does a CX4-480 array have?
- Question #62
Company.com is using a single user interface. In order to manage multiple CLARiiONs, what must exist?
- Question #63
A customer has a DAE3P configured and running at 4 Gb/s back-end speed, and you install a 2 Gb/s- only drive in the enclosure. What will the DAE3P do with the new drive?
- Question #64
Which protection type is used on the cache vault?
- Question #66
Your customer's CX4-960 array is experiencing boot problems with SPA. You observe that the fault LED for SPA is blinking amber at the rate of four times a second (4 Hz). Where did...
- Question #67
How is the Image Repository area of the CX4 vault disks protected?
- Question #68
How many GB of memory are installed in each CX4-480 SP?
- Question #69
Which four applications can be installed during a CLARalert installation?
- Question #70
Which software needs to be installed to properly configure the CLARiiON Management Station?
- Question #71
How many SPE power supplies are needed to start Write caching on a CLARiiON CX3-20?
- Question #72
The Hardware Maintenance page of the Navisphere Service Taskbar (NST) provides several wizards to aid in maintenance (not in engineering mode). One wizard allows you to upgrade the...
- Question #73
When booting the Utility Partition on a CLARiiON storage processor using a serial connection, what is the proper HyperTerminal Baud Rate used?
- Question #74
Which information Repository area of the CX4 vault sector of a degraded mode RAID 1/0 group?
- Question #75
What is the correct communication protocol between EMC and the EMC ESRS gateway?
- Question #76
It is best practice to place the iSCSI I/O module in the I/O annex first on which CX4 model?
- Question #77
A Customer Engineer is sent to a customer site to replace a storage processor (SP) in a CLARiiON CX4-960 array. What is the proper procedure to follow when replacing this unit?
- Question #78
What is required before performing a CX4 new hardware installation?
- Question #79
Which host failover software is supported with a Non-Disruptive Upgrade (NDU)?
- Question #81
A hot spare should be configured per how many FC drives in an array?
- Question #82
Where is the PSM located in the CLARiiON CX4 series array and how is it protected?
- Question #83
On a CLARiiON CX4-960 array what is the maximum number of drives supported on each back- end loop?
- Question #84
Which RAID levels provide data protection in the CLARiiON?
- Question #85
When retrieving an SPCollect from a CX4 array, what is the location of the files shown in the file transfer manager of the storage processor?
- Question #86
What is the maximum write cache value for a CX4-480 array?
- Question #87
Which CX4 model supports SATA-II drives as vault drives?
- Question #88
How much memory is installed on each CLARiiON CX3-20f SP?
- Question #89
Which utility/command line should be run on a McData switch to collect the data needed to analyze problems?
- Question #90
How many Fibre FE ports are installed in the minimum configuration on a CX4-240 array?
- Question #91
Which CX4 array model has a maximum number of two BE Fibre Channel ports per storage processor (SP)?
- Question #92
When does the PSM activate the new software on the secondary storage processor in a Non- Disruptive Upgrade (NDU)?
- Question #93
A Customer Engineer has been asked to perform an upgrade on a CX4-480 series array by adding a new DAE2P (disk-array enclosure). According to the CLARiiON Procedure Generator, what...
- Question #94
Your customer wishes to zone a Windows host HBA to Storage Processor B port 1 on a CX4-960 array. Which WWPN should be included in the zone?
- Question #95
How many bytes are contained in a physical sector on a SATA disk drive in a CLARiiON array?
- Question #96
Which FLARE log event code indicates data loss has occurred?
- Question #98
How does the factory format CLARiiON Fibre Channel drives to take advantage of the data protection scheme called the "Magic" 8 bytes?
- Question #99
Which tool/utility can be used to locate the LUN ID for the vault?
- Question #100
What does the low priority, always running, Sniff Verify operation check?
- Question #102
Which two items must be set to consider a CLARiiON array fully "initialized" by the Installation Wizard?
- Question #103
Which utility/command line collects the data needed to analyze a Brocade switch?
- Question #104
How many back-end ports are on each CLARiiON CX3-10c SP?
- Question #105
Under which failure scenario, with FLARE 28, will the array maintain cache?
- Question #106
One of the rules fails in Navisphere Service Taskbar (NST) during a FLARE upgrade. You are prompted for a password to override this individual failed rule. Which password is used t...
- Question #107
Your customer wishes to zone a Windows host HBA to Storage Processor B port 9 on a CX4-960 array. Which WWPN should be included in the zone?