E20-611 Exam Questions
397 real E20-611 exam questions with expert-verified answers and explanations. Page 3 of 8.
- Question #109
Which tool must be used to associate the Host LUN Number (HLU) to the FLARE LUN Number (FLU)?
- Question #110
A CLARiiON has two drives with bad sectors, an FC drive and an ATA drive. How will the two different drive types handle the errors?
- Question #111
Your customer has asked you to explain the RAID 5 parity and striping functions on a CX4 series array. How many stripes will you tell them occur on a disk before the parity block w...
- Question #112
What is NOT a valid feature of proactive hot sparing?
- Question #113
How many UltraFlex I/O module slots are available in a CX4-960 array?
- Question #114
Click the Exhibit button. You have been tasked with performing a Non-Disruptive Upgrade on Your customer's CX4 array. You plan to use Navisphere Service Taskbar (NST) on your servi...
- Question #115
Company.com wants assistance assigning two LUNs to a host. LUN 58 needs to appear to the host before LUN 2. Which value needs to be modified?
- Question #116
Your customer's CX4-240 array is experiencing boot problems with SPA. You observe that the fault LED for SPA is blinking amber at the rate of once every four seconds (1/4 Hz). Wher...
- Question #117
Which parity calculation method does RAID 5 use?
- Question #118
Your customer has experienced problems viewing target LUNs from one of their Windows hosts. The Support Center has requested a data collection. Which EMC supplied utility should be...
- Question #119
What is the maximum number of disk drives supported on each back-end loop of a CLARiiON CX3- 20f array?
- Question #120
When using SPLAT, what is the default log file viewing mode?
- Question #121
Click the Exhibit button. In the illustration, how should the I/O Annex correspond to the SPs from left to right?
- Question #122
How many fans are in a CX4-960 fan pack?
- Question #123
You are working on a CLARiiON where one DAE is streaming 801 errors. You are unable to trace exactly what drive or drives are causing the problem. Which tool would be best to trace...
- Question #124
A disk in a RAID 5 set has failed. While performing the rebuild to the hot spare a permanent CRC sector error is encountered on one of the remaining disks in the RAID group. What i...
- Question #125
Which CX4 array model has a maximum number of one back-end Fibre Channel port per storage processor (SP)?
- Question #126
Which operating systems support EMCRemote?
- Question #127
What are the four main sections contained in the Interactive Installation Guide (IIG)?
- Question #128
Which IP address is required when configuring Centralized monitor Email-Home during the CLARalert ConnectEMC installation?
- Question #130
On CLARiiON Fibre Channel arrays, which type of protection is used on the FLARE Db?
- Question #131
Which type of browser is supported for the Navisphere Interface?
- Question #132
Where do the analyze comments originate from when using the Analyze feature in SPLAT?
- Question #133
Which item does SPCollect contain that is NOT in the navicli getall command?
- Question #134
Company.com is having problems with their environment and Technical Support requests a full data collection using CAP2. Which information will the customer need to supply to collec...
- Question #135
In a CLARiiON array, which software component communicates with Classic Navisphere CLI commands?
- Question #136
What is the main function of the domain master?
- Question #137
Which two requirements are needed to run CAP2?
- Question #138
A RAID 5 group is running in degraded mode. Parity shedding has occurred. What is the status of the RAID group?
- Question #139
The following command was issued: naviseccli h clariion_SPA resetandhold After the command completed, SPA is no longer accessible. Which command will make SPA accessible again?
- Question #140
Which software must be installed for CAP2 to analyze files?
- Question #141
A CLARiiON CX3 SP is executing POST testing. Which frequency is the Fault LED flashing during this time?
- Question #142
A back-end loop of a CLARiiON CX3-80 is running at 2 Gb/s. All enclosures and drives are capable of 4 Gb/s. The following command was issued: naviseccli -h 10.127.94.127 backendbus...
- Question #143
Which three modes are available to view a file in SPLAT?
- Question #144
In the event of a power outage, which local repository keeps a record of the write requests that are currently outstanding?
- Question #145
How many front-end ports are on each CLARiiON CX3-20c SP?
- Question #146
Which function is an aid in identifying the correct enclosure with the failing disk?
- Question #147
Which release added SPCollect to the Navisphere GUI?
- Question #148
Why is zero-disk run during the Enhanced Installation Procedure?
- Question #149
Company.com has forgotten the storage administrative user account password. What is the solution to retrieve the account password?
- Question #150
Which two items does SPCollect contain?
- Question #151
How many front-end FC ports are on each CLARiiON CX3-40f SP?
- Question #152
What are the default Sniff parameters in release 24?
- Question #153
In a CLARiiON array, which software component communicates with Secure CLI commands?
- Question #154
What is a requirement when installing a new CLARiiON array with the Storage System Initialization Wizard?
- Question #155
What is written to the vault drives when a utility power failure occurs?
- Question #156
What is the connection type between the ATA DAE2 midplane and the disk drive?
- Question #157
When would a WebEx session be necessary?
- Question #158
How many back-end ports are on each CLARiiON CX3-20 SP?
- Question #159
You ran Background Verify on a LUN. You received the output as shown in the exhibit. Which option do you have in this situation?