E20-611 Exam Questions
397 real E20-611 exam questions with expert-verified answers and explanations. Page 1 of 8.
- Question #1
Click the Exhibit button Your customer has reported back-end issues with their FC4700 array. You have run Fibre Backend Isolation (FBI) and are analyzing the report. Which is the m...
- Question #2
When is processor throttling used in a CX4-960?
- Question #3
Optical cables are required for which connection(s)?
- Question #4
Which GUI utility in CAP2 displays storage processor event logs?
- Question #5
Click the Exhibit Button. On the CX4-960 power cabling diagram, what does "a" depict?
- Question #6
A Customer Engineer (CE) is sent to reset Storage Domain Security at a customer site. What form of communication does the Customer Engineer need to use to reset the Storage Domain...
- Question #8
Which process, internal to FLARE, will help to minimize the possibility that a disk defect will remain undetected?
- Question #9
Where is the cache vault located in the CLARiiON CX4 series array and how is it protected?
- Question #10
How many bytes are contained in a logical sector on a SATA disk drive in a CLARiiON array?
- Question #11
When performing a FLARE Code NDU on a CLARiiON array, according to the procedure generator, which item needs to be verified with the customer before proceeding?
- Question #12
Your customer has MirrorView installed and configured on their CX4-480, and they are installing two additional FE UltraFlex I/O modules in the array. Will the MirrorView ports on t...
- Question #13
When performing a proactive drive replacement on CLARiiON CX4 series, what is the preferred method?
- Question #14
How is Write cache mirrored in a CLARiiON array?
- Question #15
Which type of SCSI error is a 0x801?
- Question #16
In which area of the CLARiiON array is the ".pbu" file(s) stored?
- Question #17
Your customer has discovered that the boot images for both SPA and SPB in their CX3-80 are corrupt and will need re-imaging. The recovery image file was not loaded to the array dur...
- Question #18
When is it unsafe to remove a CX4 series storage processor (SP)?
- Question #19
On a CLARiiON CX4-480 array what is the maximum number of drives supported on each back- end loop?
- Question #20
How many BE ports does a CX4-960 array with the expansion option have?
- Question #21
The SPA event log of a CLARiiON CX4 series array has displayed the error message: 09/26/08 18:10:49 Bus0 Enc1 Dsk8 820 Soft Media Error 05 0 0 Which explanation should be provided...
- Question #22
When interconnecting DAE3Ps what is the maximum supported cable length between them?
- Question #23
Which disks in a CX4 series array contain the SPA boot images?
- Question #24
What additional reference material is included in the CLARiiON Procedure Generator?
- Question #25
Which utility is required in order for Test and Acceptance Criteria (TAC) to function?
- Question #26
The output file of an SPCollect generated from CAP2 is in which format?
- Question #28
Your customer has ordered a CX4-960 configured from the factory for only 480 drives. The customer now wants to upgrade to the 960-drive version of the CLARiiON. What needs to happe...
- Question #29
Which two services are started automatically, after installing CLARalert?
- Question #30
When booting to the utility partition on a CLARiiON storage processor using a serial connection, what are the HyperTerminal parameters?
- Question #31
Using EMC best practices what is the percentage of memory that should be allocated for read cache?
- Question #32
Click the Exhibit button. In which slot is the iSCSI module installed?
- Question #33
According to the procedure generator, as a general rule, in CLARiiON arrays with over 1 GB of cache, what is the minimum amount of memory that should be reserved for read cache?
- Question #35
How many back-end activities have to occur when modifying a single sector on a RAID 5 LUN in a CLARiiON CX4 series array?
- Question #36
When reviewing SPCollect files, which utility is used?
- Question #37
You are preparing to install a CLARiiON CX4 using the Interactive Installation Guide (IIG). The hardware was not shipped with the IIG CD. What is the best resource to use to obtain...
- Question #38
Which GUI utility is used for CLARiiON back-end loop analysis?
- Question #39
Which "Magic Byte" is used by Background Verify to detect incomplete writes of a partial (sub) stripe?
- Question #40
A disk in a RAID 6 set has failed. While performing the rebuild to the hot spare a permanent CRC sector error is encountered on one of the remaining disks in the RAID group. What i...
- Question #41
After installing CLARalert on a workstation, which two applications will need to be configured?
- Question #42
Which two LUN parameters can be changed by using the LUN Properties dialog box?
- Question #43
Why should SPLAT have SPCollects from both SPs when troubleshooting array problems?
- Question #44
What tool is recommended for use when reviewing SPCollects for 820 Soft Media Errors?
- Question #45
What is indicated in a CX4 if the Fault LED on an SP is blinking blue at a frequency of 1 Hz?
- Question #46
Under which scenario are the benefits of FLARE 28 realized?
- Question #47
Click the Exhibit button. Your customer has reported back-end issues with their CX700 array. You have run Fibre Backend Isolation (FBI) and are analyzing the report. What is the mo...
- Question #48
Click the Exhibit button. Which LED would indicate when a CX4 series array is currently Vaulting Cache?
- Question #49
During which time is cache performance at its peak?
- Question #50
In FLARE release 24, what are the three tabs in an Enterprise Storage window?
- Question #51
Which disks in a CX4 series array contain the SPB boot images?
- Question #52
When a storage processor is booting up the LED is blinking at ?Hz blue (once every four seconds). What is the boot state of the storage processor?
- Question #53
How many power supplies/blower modules are needed to start mirrored write caching on a CLARiiON CX4-480?