DNDNS-200 Exam Questions
90 real DNDNS-200 exam questions with expert-verified answers and explanations. Page 1 of 2.
- Question #1
Refer to the exhibits. A network administrator has worked with PC support to install a new PC. After correctly configuring the PC's interfaces with valid IP addresses, the PC is no...
- Question #2
The Port 0/1/1 LED is blinking RED for an N-Series switch. Which system behavior is indicated?
- Question #3
Refer to the exhibit. A network engineer is called onsite to troubleshoot replication failure and traffic loss. Whenever replication occurs between SAN A and SAN B, users report tr...
- Question #4
Refer to the exhibit of the N-series switches. The exhibit shows a Layer 2 network between Host A (a Desktop Computer running Windows 7) and Host B (another Desktop Computer runnin...
- Question #5
Refer to the exhibit. Considering the network topology and information shown, what is an end point devices in network 192.168.102.0/24 that to route to 192.168.101.0/24?
- Question #6
Refer to the Exhibit. A network engineer receives the output shown when removing MLAG from a pair of N-Series switches. Which command sequence must the engineer complete to remove...
- Question #7
A network engineer has connected a Port Extender to a C-Series switch. While issuing the command "show pe brief" on the C-Series switch, the engineer sees a status of "offline". Wh...
- Question #8
A customer upgrades its C-Series switch and is experiencing a constant boot loop. Which two upto allow the switch to boot successfully using the newer firmware? (Choose two.)
- Question #9
A network engineer needs to summarize the IP range of addresses from 172.16.32.0 to 172.16.39.255. What is the most effective choice?
- Question #10
From the front of a C-Series switch, in which direction does air flow?
- Question #11
Refer to the exhibit. A network engineer is installing a new Dell S-Series switch on the rack and notices that the Power LED is blinking yellow. What is causing this behavior on th...
- Question #12
A network engineer powers on a new S-Series switch. None of the devices connected to this new switch are responding to pings. Which two conditions should the network engineer verif...
- Question #13
On an N-Series switch, which three outputs display when a network engineer runs the command `show system`? (Choose three.)
- Question #14
A network engineer configures a new S-Series switch. When the network engineer reloads the switch, the running configuration is defaulted. What are two reasons to explain this beha...
- Question #15
Which three components can be used to deploy 10GbE N-Series switches in a user-port stack configuration? (Choose three.)
- Question #16
A network deployment engineer needs to deploy four Dell Networking N1500 series switches. All switches are to be stacked together using 10Gbe ports on each switch. The requirement...
- Question #17
Which component is required to deploy the N2000/N3000 Series switches in a stack configuration?
- Question #18
Refer to the output. According to the partial configuration, which two things have occurred? (Choose two.)
- Question #19
Refer to the exhibit. A customer has a C-Series chassis using a 48-port PoE+ line card. A workstation connected to Gi 0/47 passes traffic as expected. When the customer connects a...
- Question #20
A network engineer has two Dell Networking switches: an N-Series and an S-Series. Both switches have the factory default configuration. Which phrase correctly describes the current...
- Question #21
Refer to the exhibit. A Dell SAN deployment consisting of a single Dell server and EqualLogic storage array on a segregated VLAN communicating over a C9010. The storage arrays are...
- Question #22
Refer to the exhibit. A network engineer is unable to ping from VLAN 30 across two S-Series switches. Port 13 on switch Dell1 and Port 43 on switch Dell2 both have a link status of...
- Question #23
Refer to the exhibit. On switch S4820-1, commands are entered. The associated output is as shown. A network engineer enters the following command: `S4820-1(conf-stpd)#vlan 3 bridge...
- Question #24
Which statement describes what will happen when a ping is sent from Dell-1 to Dell-2?
- Question #25
Given the output from an N-Series switch, how many instances of VRF are running?
- Question #26
Refer to the exhibit. The deployment engineer needs to use rapid PVST+ so that some traffic is forwarding on all inter-switch links on these three N-Series Switches. To do so, each...
- Question #27
Refer to the exhibits. An organization has a network with the following configuration: - It uses two Dell N-Series chassis. - Each chassis has 10Gb line cards in each C-Series chas...
- Question #28
Which command MUST have been entered previously on switch S4820-1?
- Question #29
In an OSPF network, what happens if the OSPF Priority level is set to "0"?
- Question #30
A customer needs to convert S-Series stacked switches to a VLT configuration to maintain port-channels from the customer's server. The customer's S-Series switches have been IEEE 8...
- Question #31
Refer to the exhibit. The customer wants to deploy a two-tier OSPF ECMP Core in the configuration shown. All uplinks to the spine are 40Gbps. All uplinks to the leaves are 10Gbps....
- Question #32
A customer has two locations that are six miles apart and connected by customer-owned dedicated fiber. The customer tells the deployment engineer that the two sites have to be conn...
- Question #33
A network engineer needs to install five Dell N-Series switches in a stack for a company that is moving to a new building. The following items are received: - 5x Dell N4032 switche...
- Question #34
A network engineer needs to apply Layer 2 port security on an existing N-Series switch. The customer wants to prevent end-users from plugging in their personal laptop in a LAN port...
- Question #35
Refer to the exhibit. The network is being over utilized. A network engineer needs to resolve the issue by pruning the trunk links of unnecessary vlans. Each switch must be managem...
- Question #36
Refer to the exhibit. Two S-Series switches have been configured as a VLT Pair. Which three conclusions should be made based on the output shown from the first peer switch? (Choose...
- Question #37
Which three properties are required for two OSPF router interfaces to establish a neighbor relationship? (Choose three.)
- Question #38
In an S-Series switch, what two events occur when a static null route has been configured in the system to drop a packet? (Choose two.)
- Question #39
A network engineer needs to create an IEEE 802.3ad Port-Channel between two S-Series switches using ports Tengigabit Ethernet 0/1 to Tengigabit Ethernet 0/4. Which commands should...
- Question #40
A network engineer is configuring several trunk ports for VLAN 50 and VLAN 100 on an N-Series switch. VLAN 50 and 100 are newly added VLANs. These are the current commands. Which c...
- Question #41
A networking engineer needs to configure several VLANs for S-Series switches for both Untagged and Tagged traffic. Which statements are TRUE regarding VLANs? (Choose two.)
- Question #42
Which three cabling items should be considered when stacking N4000 Series switches? (Choose three.)
- Question #43
What are the characteristics of port-based VLANs on S-Series switches? (Choose three.)
- Question #44
A network engineer removes a new Dell Networking N-Series switch from the original shipping container and initially configures STP on the switch. While the engineer is configuring...
- Question #45
A network engineer needs to remove switch 2 from a stack of four switches permanently. Which procedure should the network engineer use?
- Question #46
A network engineer is implementing MLAG using two N-Series switches. MLAG must be set up with 10 Gb ports and connecting to a single S-Series switch that will be the host for the M...
- Question #47
Refer to the exhibit. The switches must be able to have full reachability to the entire networking fabric through the use of static routes. All other devices have reachability to S...
- Question #48
A new switch stack has been implemented. The network engineer needs to verify that all switches in the stack are running the same firmware. Which command should be used to verify s...
- Question #49
A new switch is already configured with an IP address and is reachable within the network. SSH and HTTPS are verified. The network engineer needs to disable both to prevent unauthe...
- Question #50
In a Dell network, a network engineer uses a loopback interface with an assigned IP Address instead of configuring an IPv4 address as the Router I. What are two benefits of this ch...