5V0-22.21 Exam Questions
160 real 5V0-22.21 exam questions with expert-verified answers and explanations. Page 2 of 4.
- Question #51Planning and Design VMware HCI Implementations
A business unit requires proprietary data to be protected against a site failure while using the least amount of storage and the least amount of nodes. AN administrator plans to im...
vSAN stretched clusterRAID-5 erasure codingminimum nodescapacity planning - Question #52Deploy and Configure VMware HCI
Which two requirements should the vSAN administrator consider in order to accomplish this goal? (Choose two.)
vSAN HCI Meshnetwork latency requirementsLayer 2 Layer 3NIC teaming - Question #53Deploy and Configure VMware HCI
A new host with local storage devices has been added to a vSAN cluster. Now, the administrator would like to increase the capacity of the vSAN datastore. What must be done to the n...
disk groupsvSAN capacity expansionhost storage configurationvSAN datastore - Question #54Troubleshoot and Repair VMware HCI
The objects on a 4-node vSAN cluster are assigned a RAID-5 policy. A network outage occurs, causing host one to lose connectivity with the rest of the cluster. Seventy-five minutes...
vSAN rebuild timerRAID-5 object healthnetwork outagereduced availability - Question #55Deploy and Configure VMware HCI
Which two actions are recommended when adding a host to a vSAN cluster? (Choose two.)
host addition best practicesVMware Compatibility Guidehost uniformityvSAN cluster expansion - Question #56VMware HCI Solutions
An Application Clustering Solution requires an in-guest attachable LUN which can be shared across two different VMs. Which vSAN feature can meet this requirement?
vSAN iSCSI target serviceshared LUNapplication clusteringin-guest storage - Question #57Deploy and Configure VMware HCI
A vSAN administrator has been asked to encrypt all traffic for data and metadata across all hosts in a vSAN cluster. Which action is necessary to achieve this level of encryption?
data in-transit encryptionvSAN cluster encryptionKMS requirementsmetadata encryption - Question #58Administer and Operate VMware HCI
A vSAN administrator is receiving complaints that applications are not performing as expected. The vSAN administrator opens the vSAN cluster performance charts to try to identify t...
vSAN Performance Serviceperformance chartscluster monitoringperformance diagnostics - Question #59Administer and Operate VMware HCI
A 5-node vSAN cluster contains multiple virtual machines, and a vSAN storage policy with the rule "Failures to tolerate" set to "1 failure -RAID-5 (Erasure Coding)" is assigned. A...
RAID-6 erasure codingstorage policy changecluster node requirementsFTT=2 - Question #60VMware HCI Solutions
Which solution can automate the deployment of a vSAN cluster as part of a full Software-Defined Datacenter?
VMware Cloud FoundationSDDC automationvSAN deploymentsoftware-defined datacenter - Question #61Administer and Operate VMware HCI
What is the purpose of host rebuild reserve in vSAN?
host rebuild reservecapacity reservationhost failure protectionvSAN capacity - Question #62Administer and Operate VMware HCI
A vSAN administrator is deploying multiple 2-node clusters to remote branch offices. The nodes already have an old vSphere 7.0 image, but the administrator would like to update the...
vLCM image management2-node clusterimage export formatJSON - Question #63Troubleshoot and Repair VMware HCI
A remote location was configured with Cloud Native Storage. When the administrator put the host in maintenance mode to perform monthly patching, the File Server Health check was tr...
Cloud Native Storagemaintenance modeFile Server Healthrepair delay timer - Question #64Administer and Operate VMware HCI
Which two prerequisites are required before a vSAN administrator is able to use the vSAN Performance Diagnostics feature? (Choose two.)
vSAN Performance DiagnosticsPerformance ServiceCEIPdiagnostics prerequisites - Question #65Troubleshoot and Repair VMware HCI
During yesterday's business hours, a cache drive failed on one of the vSAN nodes. The administrator reached out to the manufacturer and received a replacement drive the following d...
cache drive failuredisk group replacementvSAN recovery proceduremaintenance mode - Question #66
Which two conditions should be verified before removing an ESXi host from a vSAN cluster? (Choose two.)
- Question #67Planning and Design VMware HCI Implementations
In a 2-node vSAN cluster, one node has recovered from failure with FTT=1 and RAID-1 storage policy. Refer to the exhibit. What is the total VMDK storage consumed?
RAID-1 mirroring2-node clusterstorage consumption calculationFTT=1 - Question #68Optimize and Scale VMware HCI
A vSAN administrator is implementing deduplication and compression on a vSAN all-flash cluster but wants the VMs to remain operational. The details are as follows: - There are 4 no...
deduplication compressionall-flash clusterallow reduced redundancyrolling reformat - Question #69Troubleshoot and Repair VMware HCI
Skyline Health vSAN HCL DB up-to-date health check is alerting in red in a newly deployed vCenter Server. Which two options are the possible solutions for this problem? (Choose two...
Skyline HealthvSAN HCL DBhardware compatibilityoffline bundle update - Question #70Planning and Design VMware HCI Implementations
A new vSAN Cluster with four hosts has to be designed for a single site architecture. Which design decision is correct?
vSAN cluster designVMware Compatibility Guidesingle site architecturehardware selection - Question #71VMware HCI Solutions
An organization is facing vSAN storage capacity challenges on one of their vSAN enabled clusters, while other vSAN enabled clusters are underutilized. The current vSAN version is 7...
vSAN HCI Meshstorage capacitycluster utilizationvSAN 7.0 - Question #72Administer and Operate VMware HCI
The Resyncing Objects view in the vCenter UI reports that some objects are currently resyncing. Which two actions would cause this situation? (Choose two.)
object resynchost failurestorage policyvSAN health - Question #73Optimize and Scale VMware HCI
An administrator will be performing a rolling upgrade of a vSAN cluster over the weekend. In preparation, the administrator runs the Data Migration Pre-Check. Which two items are b...
data migration pre-checkrolling upgradeobject compliancecluster capacity - Question #74Deploy and Configure VMware HCI
A newly deployed vSAN cluster runs vSAN 7.0, and the vSAN cluster needs an integration with a third-party software solution. The software solution provides full app-level redundanc...
vSAN DirectData Persistence platformstorage policytag-based placement - Question #75VMware HCI Platform and Architecture
Which VM file type resides in the VM home namespace object on a vSAN datastore?
VM home namespacevSAN datastorevmx fileVM storage objects - Question #76Planning and Design VMware HCI Implementations
A vSAN administrator is looking at adding a new vSAN cluster with hosts that have 512GB memory. What is the minimum requirement for the node's flash boot device?
flash boot devicevSAN requirementshost memoryhardware prerequisites - Question #77Optimize and Scale VMware HCI
All of the virtual machines running on a hybrid vSAN datastore have this storage policy assigned: Failures to Tolerate (FTT) rule is set to "2 Failures -RAID-1 (Mirroring)". The vS...
storage policyFTTRAID-1capacity optimization - Question #78Troubleshoot and Repair VMware HCI
After a server power failure, the administrator noticed the scheduled resyncing in the cluster monitor displays objects to be resynchronized under the pending category. What are th...
resync pendingcluster monitorobject synchronizationvSAN health - Question #79Administer and Operate VMware HCI
Which option, if any, is the default option to enable Maintenance Mode on a vSAN host?
maintenance modedata migrationensure accessibilityvSAN host - Question #80Deploy and Configure VMware HCI
A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task. What is the fastest...
host profileReadyNodescluster expansionQuickstart - Question #81
A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the cluster are compliant ac...
- Question #82
An existing vSAN cluster has this specification: - Four ESXi hosts with all flash configuration - Each with two disk groups - Each disk group with one cache device and four capacit...
- Question #83Troubleshoot and Repair VMware HCI
An administrator wants to check the vSAN cluster health during the maintenance window while vCenter Server is offline. What are two ways to complete this task? (Choose two.)
cluster healthesxclivSphere Host ClientvCenter offline - Question #84Troubleshoot and Repair VMware HCI
A vSAN administrator is troubleshooting poor performance of vSAN cluster while vCenter is not available. The vSAN administrator decides to use a command line tool to monitor real-t...
vsantopperformance monitoringIOPSCLI tools - Question #85Planning and Design VMware HCI Implementations
A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources. Which two strategies should the vSAN admin...
fault domainsrack failureRAID-6resource maximization - Question #86Deploy and Configure VMware HCI
Which Storage Policy Structure Rule is supported by vSAN Direct Datastore?
vSAN Directstorage policytag-based placementcapacity-based rules - Question #87Troubleshoot and Repair VMware HCI
A vSAN administrator was examining the status of Virtual Objects and found inaccessible objects that are occupying significant storage capacity. Refer to the exhibit. Which action...
inaccessible objectsstorage capacityobsolete objectsvirtual objects - Question #88Administer and Operate VMware HCI
A vSAN storage policy with the 'Failures lo Tolerate" rule set to "2 failures -RA1D-1 (Mirroring)" is assigned to multiple virtual machines. The vSAN administrator is considering a...
RAID-6erasure codingstorage policy changecapacity impact - Question #89Administer and Operate VMware HCI
Which two storage policy changes result in a component resync? (Choose two.)
component resyncstorage policyfailure tolerance methodobject checksum - Question #90Optimize and Scale VMware HCI
A vSAN administrator has been asked to increase the usable storage capacity of an existing vSAN cluster to deploy some new virtual machines containing a large amount of data. The d...
capacity expansiondisk groupscapacity devicescost optimization - Question #91Deploy and Configure VMware HCI
A vSAN administrator is deploying a four node vSAN cluster to a new work location. To help with configuration and consistency, the vSAN administrator plans to use Ouickstart. Which...
Quickstartcluster deploymentprerequisitesvSAN configuration - Question #92VMware HCI Solutions
An administrator has deployed a dedicated VMware vSAN 7.0 U1 cluster that will be used to provide developers with access to an environment that is running VMware with Tanzu workloa...
vSAN Data Persistence platformTanzushared nothing architecturecloud native storage - Question #93Administer and Operate VMware HCI
A vSAN administrator wants to upgrade a 4-node vSAN Cluster from version 7.0 to the latest version available. The vSAN administrator would like to complete the upgrade as a single...
vLCMlifecycle managementfirmware upgradevSAN upgrade - Question #94Deploy and Configure VMware HCI
A vSAN administrator has been provided hardware to create the vSAN infrastructure. AH six SSD devices per host are on the VMware HCL. The administrator wants to use the disk group...
disk groupsvSAN cacheSSD configurationstorage performance - Question #95Troubleshoot and Repair VMware HCI
A vSAN Administrator has a cluster of six vSAN nodes. The vSAN datastore was 55% utilized, and due to a power outage, one node was lost. The vSAN administrator needs to resolve the...
RAID-5FTTstorage policy compliancenode failure - Question #96Administer and Operate VMware HCI
An administrator needs an esxcli system command that will place a vSAN host into maintenance mode using the "Ensure Accessibility" option. Which esxcli system command, if any, will...
esxclimaintenance modeensure accessibilitycommand syntax - Question #97VMware HCI Platform and Architecture
What are two prerequisites for using the TRIM and UNMAP capability of vSAN? (Choose two.)
TRIMUNMAPall-flashguest OS support - Question #98Troubleshoot and Repair VMware HCI
A storage administrator is facing degraded performance for the VMs running on a vSAN enabled vSphere Cluster and needs an out-of-the-box tool to identify the root cause of the prob...
vsantopperformance monitoringtroubleshooting toolsvSAN diagnostics - Question #99VMware HCI Solutions
A vSAN Administrator would like to save some space on workloads that do not take advantage of deduplication techniques by leveraging vSAN Compression only. Which set of requirement...
vSAN compressiondeduplicationvSAN licensingversion requirements - Question #100Planning and Design VMware HCI Implementations
A vSAN administrator wishes to implement HCI mesh between two clusters that are located in geographically separate data centers. Which recommendation should the vSAN administrator...
HCI meshnetwork topologyLayer 2 Layer 3cross-datacenter