NS0-509 Exam Questions
168 real NS0-509 exam questions with expert-verified answers and explanations. Page 2 of 4.
- Question #56
Exhibit: Referring to the exhibit, which container gains space savings from deduplication, compression and compaction?
- Question #57ONTAP SAN Solutions Implementation
Exhibit: A customer needs to change ports 0e and 0f on AFF_1 to support FC. Referring to the exhibit, which three steps are required to accomplish this task? (Choose three.)
UTA2 portsucadminFC target modeport conversion - Question #58ONTAP SAN Solutions Design
You want to connect a NetApp AFF A700 to a 32 Gb FC switch. The ports need to connect at 32 Gb speed. In this scenario, which statement is correct?
AFF A70032Gb FCunified I/O modulehardware selection - Question #59ONTAP SAN Solutions Management
Exhibit: You are troubleshooting high CPU use on a FAS8200 with all SAS HDDs. You have SAN hosts with LUNs in a volume named vol1. You want to reduce CPU use and maintain storage e...
inline deduplicationCPU optimizationdata compactionstorage efficiency - Question #60ONTAP SAN Solutions Design
An administrator has an AFF A200 cluster at their primary site that is used for FC connectivity to servers. For disaster recovery purposes they want to start replicating their data...
SnapMirrorDR designiSCSI failoverSVM configuration - Question #61
Exhibit: Referring to the exhibit, which type of zoning should be used?
- Question #62ONTAP SAN Solutions Management
Exhibit: A customer has an AFF A200 with a LUN residing in a volume by Node 4. The default Selection Mapping settings are effect. During a planned takeover cluster test, Node 3 per...
SLMstorage failoverFC path countmultipath behavior - Question #63ONTAP SAN Solutions Management
You have inherited a small FC SN infrastructure that consists of 15 servers (hosts), two Cisco MDS 9148s switches, and a 4-node NetApp AFF A300 cluster. You suspect that your prede...
FC zoning auditSVM LIF WWPNHBA WWPNzoning best practices - Question #65ONTAP SAN Solutions Management
Exhibit: Referring to the exhibit. What are two viable scenarios to test LUN multipathing on Host 1? (Choose two.)
LUN multipathingFC path testingfailover simulationpath validation - Question #66ONTAP SAN Solutions Design
Which formula is appropriate for calculating target port Queue Depth?
queue depthtarget port LIFHBA queue depthFC performance - Question #67ONTAP SAN Solutions Design
When planning out a new FC SAN implementation for a AFF cluster, which two variables should be considered for a highly-available, resilient solution? (Choose two.)
HA designdual fabricPDU redundancyFC SAN resilience - Question #68ONTAP SAN Solutions Troubleshooting
Exhibit: A customer is testing a dual-fabric FC SAN configuration as shown in the exhibit and the zones are implemented on the switches shown below. If all the nodes are in the SLM...
SLM reporting nodesdual fabric path countLIF failureFC path calculation - Question #69ONTAP SAN Solutions Troubleshooting
An administrator has a 2node AFF ONTAP cluster named cl1. A Windows 2016 server has 10 FC LUNs mapped from the cluster , and the administrator can multiple paths to each LUN, Durin...
MPIOstorage failoverLUN connectivitymultipathing software - Question #70ONTAP SAN Solutions Management
Exhibit: Referring to the exhibit, which two statements are true? (Choose two.)
LUN space reservationvolume guaranteethin provisioningspace management - Question #71ONTAP SAN Solutions Implementation
You want to provision an iSCSl LUN. Which two steps are required to accomplish this task? (Choose two.)
iSCSI LUN provisioningigroupIQNLUN mapping - Question #72ONTAP SAN Solutions Management
Which NetApp tool views automated, schedule configuration, and performance data for a customer's SAN from a Web browser?
OnCommand Workflow AnalyzerSAN management toolsperformance monitoringNetApp toolset - Question #73ONTAP SAN Solutions Troubleshooting
A storage administrator created a LUN using two ports on a storage system. Later, additional LUNs were added to the same node as the original LUN. After a while, the performance of...
LIF configurationport utilizationSAN performanceload balancing - Question #74ONTAP SAN Solutions Design
Which two scenarios in deploying ONTAP Cloud are supported by the Cloud Manager tool? (Choose two.)
ONTAP CloudHA paircloud deploymentAzure - Question #75ONTAP SAN Solutions Implementation
An administrator is planning a hardware refresh and data migration from a Data ONTAP 7.3 system to new AFF A3-00 cluster that is using ONTAP 9.0. The Mode system only serves FC LUN...
7-Mode Transition Tooldata migrationFC LUNs7MTT - Question #76ONTAP SAN Solutions Troubleshooting
Exhibit: The VMware ESX host discovers only two of four paths to a LUN on a new ONTAP cluster. Referring to the exhibit, which statement Is correct?
multipathFC zoningHBA connectivitypath discovery - Question #77ONTAP SAN Solutions Design
A customer wants to use both Cisco FC and FCoE switches in their ONTAP environment. According to NetApp best practices, what are two requirements in this scenario? (Choose two.)
FC zoningFCoEsingle initiator zoningbest practices - Question #78ONTAP SAN Solutions Troubleshooting
You are provisioning a LUN using an ISCSI initiator on an ESX host. You disable Ethernet flow control for all ports but are experiencing Performance issues. In this scenario, which...
iSCSI performancejumbo framesdedicated portsEthernet flow control - Question #79ONTAP SAN Solutions Troubleshooting
Exhibit: You are adding a boot LUN for a new server. The server uses FCP attached through a CN
FC zoningWWPNboot LUNzone activation - Question #80ONTAP SAN Solutions Implementation
An administrator needs to connect a new VMware 6.5 cluster to an ONTAP cluster for iSCSl connectivity. Which two steps would accomplish this task? (Choose two.)
iSCSI connectivityVMware ESXiswitch selectionSAN implementation - Question #82ONTAP SAN Solutions Management
What does the space allocation argument in a lun create command do?
LUN provisioningspace allocationthin provisioningspace reclamation - Question #83ONTAP SAN Solutions Design
An enterprise customer has both a NetApp FAS8200 4-node cluster and a third-party storage array in a shared SAN environment. The host servers connect to both storage vendors' array...
heterogeneous SANHBA adaptersmulti-vendorbest practices - Question #84
Exhibit: You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AF...
- Question #85ONTAP SAN Solutions Design
You ate deploying an 8-node FAS8200 ONTAP cluster and attaching to an existing FC fabric. Which two ONTAP features would be used to restrict or limit the available paths seen from...
Selective LUN Mapport setspath managementFC fabric - Question #86ONTAP SAN Solutions Troubleshooting
A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and C...
HBA queue depthVSC host settingsFC connectivityintermittent failure - Question #87ONTAP SAN Solutions Management
Exhibit: Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the /vo1/vo1_sanlunsiprod_03 volume?
space guaranteesLUN thin provisioningvolume spacespace reservation - Question #88ONTAP SAN Solutions Management
Exhibit: IF all the nodes are in the SLM reporting nodes list, how many paths per LUN should the customer expect when simulating a node failure by powering off Node 04?
Selective LUN MapSLM reporting nodespath failovernode failure - Question #89ONTAP SAN Solutions Management
You have a 4-node cluster with a FAS8200 HA pair and an AFF A300 HA pair. You need to migrate a LUN from a FAS8200 node to an AFF A300 node for faster performance. Which method wil...
LUN copysnapshot retentiondata migrationnon-disruptive migration - Question #90ONTAP SAN Solutions Implementation
Exhibit: You need to configure the SnapCenter Plug-in for VMware vSphere to back up and restore VMware datastores. Referring to the exhibit, which additional LIF type should you cr...
SnapCenterLIF typesSVM management LIFVMware vSphere - Question #91ONTAP SAN Solutions Implementation
You are setting up FC ports and must configure the speeds for both the SAN and the host ports. In this scenario, which statement is correct?
FC port speedauto-negotiationSAN configurationbest practices - Question #92ONTAP SAN Solutions Management
Exhibit: You want to map a LUN to a server. To which SAN object is the highlighted value in the exhibit added?
igroupLUN mappingWWPNSAN objects - Question #93ONTAP SAN Solutions Management
You must relocate a LUN from one AFF A700 HA pair to another AFF A300 HA pair while preserving all storage efficiencies. What are two ways to accomplish this task? (Choose two.)
LUN relocationvolume copystorage efficiencydata migration - Question #94ONTAP SAN Solutions Implementation
An SVM's LUN setup needs to have LIFs that are configured for FC access and iSCSI access. The administrator will also be using NetApp Virtual Storage Console. In this scenario, whi...
LIF typesFC LIFsiSCSI LIFsVirtual Storage Console - Question #95
A customer's Red Hat Linux 7.0 server's Linux native DM-MP settings for multi pa thing have not been set correctly. In this scenario, what would cause this problem?
- Question #96ONTAP SAN Solutions Troubleshooting
A4-node ONTAP FAS9000 cluster was used to serve I/O from six RedHat 7.3 servers. The servers were configured with maximum, queue depth. For production purposes, an additional 60 si...
QFull errorsFC HBA queue depthFC target HBAsSAN performance - Question #97ONTAP SAN Solutions Design
A customer wants to move its iSCSI SAN data from the edge locations into the cloud for data analytics, while keeping the ability to access modify the data. Which two combined solut...
SnapMirrorONTAP Selectcloud integrationiSCSI SAN - Question #98ONTAP SAN Solutions Management
You need to move a LUN non-disruptively from an AFF A200 HA pair to an AFF A700 HA pair within the same 4-node cluster using the steps shown below. 1. Scan the host OS to discover...
LUN movereporting nodesnon-disruptive operationsSelective LUN Mapping - Question #99ONTAP SAN Solutions Design
Which two components must be verified for a supported NetApp SAN confutation? (Choose two.)
SAN configuration validationhost multipathhost bus adapterNetApp IMT - Question #100ONTAP SAN Solutions Management
You want to access and mount a Linux L.UN using only iSCSl. In the past, the LUN ha;; been accessed using FC. What must you do to accomplish this task?
igroupLUN mappingiSCSI migrationprotocol change - Question #101ONTAP SAN Solutions Implementation
Exhibit: You want to configure a UTA2 port as an FCoE target. Referring to the exhibit, which action must be performed?
UTA2 portFCoECNA modeport configuration - Question #102ONTAP SAN Solutions Design
You are planning few a new AFF A700 2-node switchless FC solution with two Cisco 9100 switches. Each AFF A700 will have one 16 Gb port Connected to each Cisco 9100 switch and four...
FC zoningsingle initiator zoningzone calculationdual-fabric - Question #103ONTAP SAN Solutions Implementation
An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process. What must the adm...
Foreign LUN ImportFLISAN migrationzoning - Question #104ONTAP SAN Solutions Management
Exhibit: You are asked to change the iSCSl Target Node Name of an SVM named SVM1 that is serving data. Referring to the exhibit, which two statements are correct? (Choose two.)
iSCSI target node nameSVM configurationiSCSI managementCLI - Question #106ONTAP SAN Solutions Troubleshooting
Exhibit: Dining a data mobility test on a 4-node ONTAP 9.3 cluster, the host loses direct access to its LUNs. The LUNs are hosting on node cl1-01 and are being moved to cl1-03 on a...
reporting nodesvolume moveLUN accessdata mobility - Question #107ONTAP SAN Solutions Troubleshooting
You have a 4-node FAS8200 A300 cluster that are using ONTAP 9.3 default settings. For faster performance, you move a volume with LUNs from a node on the FAS8200 to a node on the AF...
reporting nodesALUAFC path optimizationvolume move - Question #108ONTAP SAN Solutions Troubleshooting
Exhibit: The host in the exhibit is connected to a 4-node ONTAP SAN using dual-fabric implementation. LUNs have been mapped LUN through all available UFs on nil (our nodes. Switch...
dual-fabricpath countHA testingswitch failure