NS0-509 Exam Questions
168 real NS0-509 exam questions with expert-verified answers and explanations. Page 1 of 4.
- Question #1ONTAP SAN Solutions Implementation
Exhibit: You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI...
iSCSI LUN mappingigroup configurationSVM iSCSI setupLIF protocol - Question #2ONTAP SAN Solutions Design
You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration. In this scenario, which front end configuration is required for non-disruptiv...
MetroClusteriSCSI LUN failoverintercluster LIFnon-disruptive operations - Question #3ONTAP SAN Solutions Implementation
Exhibit: Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.)
FC SAN LIFport configurationFC adaptersLIF creation - Question #4
You have a 4-node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that...
- Question #5ONTAP SAN Solutions Design
Exhibit: You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN. Using MAX Data as shown...
MAX Datastorage class memorySAN protocolslow latency design - Question #6ONTAP SAN Solutions Troubleshooting
A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth...
FC queue depthhost connectivityiSCSI queue depthHBA configuration - Question #7ONTAP SAN Solutions Implementation
You want to ensure maximum performance of iSCSI LUNs on an AFF A220. In this scenario, which two actions will accomplish this task? (Choose two.)
iSCSI performanceMTU jumbo framesVSC VMwareiSCSI adapter binding - Question #9ONTAP SAN Solutions Troubleshooting
Exhibit: A customer has an AFF A700 connected to a Cisco switch and has verified connectivity but cannot see any LUNs. The customer issued the run -node scaling-01 - command fcp to...
FCP topologyCisco switch VFCFC connectivityNPIV - Question #11ONTAP SAN Solutions Design
Exhibit: You have an existing 2-node AFF A300 cluster with premium bundle licensing applied. You need to have consistently low front end latency, and have determined that NVMe sati...
NVMe/FC32Gb FC HBAAFF A300 expansionNVMe licensing - Question #12ONTAP SAN Solutions Troubleshooting
You have a thin-provisioned LUN that was created by using the lun create -vserver vs1 - path /vol/vol1/lun1 -size 500G -ostype windows 2008 -space-reserve disabled -space-allocatio...
thin provisioningspace allocationLUN space reclamationWindows host SCSI UNMAP - Question #14ONTAP SAN Solutions Management
Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.)
ANANVMe multipathingpath managementasymmetric namespace access - Question #15ONTAP SAN Solutions Troubleshooting
A customer that is using an AFF A220 has a problem with a host for a new FC LUN. Other LUNs on the same SVM are working properly. This LUN is not visible on the host. Which configu...
FC LUN visibilityFC target portigroup LUN mappingFC troubleshooting - Question #16ONTAP SAN Solutions Design
A customer has an existing 8-node cluster that consists of six FAS2650 nodes and two FAS2554 nodes. The customer wants to expand the cluster by adding two AFF A220 nodes. Which res...
mixed cluster supportcluster expansionConfig AdvisorAFF A220 - Question #17ONTAP SAN Solutions Troubleshooting
You deployed a new SVM for FC access, and you used the vserver fcr, create -vserver svm1 - status- admin up command to enable FC service on the SVM. You then created the LIFs for t...
FC LIF operational statusFC zoningSVM FC serviceLIF bring-up - Question #18ONTAP SAN Solutions Design
Exhibit: A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Currently, there are cards in slots 1, 2, 4, 6, 8, and 9. Referring to the e...
NVMe/FCFC adapter slotAFF A700 hardwarePCIe slot selection - Question #19ONTAP SAN Solutions Implementation
Exhibit: Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.)
NVMe/FC requirements32Gb FC HBANVMe licensingONTAP 9.5 - Question #20ONTAP SAN Solutions Design
A customer is required to encrypt iSCSI traffic across their public network. In this scenario, which method will accomplish this task?
iSCSI encryptionIPsecdata-in-transit securitynetwork security - Question #21
You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Window...
- Question #22ONTAP SAN Solutions Management
As a system administrator, you perform a routine check of available storage space on your FAS2750. You notice that the vol_1 volume is approaching 100% capacity. The volume is conf...
volume capacity managementspace guaranteeLUN reservationdeduplication - Question #23ONTAP SAN Solutions Management
An administrator reviews the Upgrade Advisor before performing an upgrade of their ONTAP cluster. What information is detailed in the report? (Choose two.)
Upgrade AdvisorONTAP upgradepre-upgrade checkscluster interconnect - Question #24ONTAP SAN Solutions Implementation
You want to create an additional SVM from the System Manager GUI to serve data only using block- based protocols. You know the SVM name, the aggregate containing the root volume, a...
SVM creationblock protocolsSystem Managerroot volume security style - Question #25ONTAP SAN Solutions Design
An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic fr...
iSCSI switch configurationMTUVLAN segmentationEthernet network design - Question #26ONTAP SAN Solutions Implementation
You are implementing a new AFF A800 HA pair and are required to migrate NetApp E-Series E2624 data to the AFF A800 controllers. You do not have a host server that is available for...
FLIdata migrationE-Serieshost-free migration - Question #27
You have three Windows servers and one Linux server, each with dual-ported HBAs that are connected into a dual fabric. In this scenario, what is the minimum number of zones that yo...
- Question #28ONTAP SAN Solutions Troubleshooting
Exhibit: An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The...
SVM LIFsLUN accessmultipath connectivitySAN troubleshooting - Question #30ONTAP SAN Solutions Management
Automatic host-side space management with SCSI T10 thin-provisioned LUNs is achieved by which feature of ONTAP?
space allocationSCSI T10thin provisioninghost-side space management - Question #31ONTAP SAN Solutions Design
You are planning to expand a SAN-only ONTAP 9.5 cluster that consists of eight AFF A700 nodes. In this scenario, what is the maximum number of additional AFF A700 nodes that would...
cluster scalingSAN-only clusterAFF A700node limits - Question #32ONTAP SAN Solutions Management
You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that...
inline compactionLUN movestorage efficiencydata compaction - Question #33ONTAP SAN Solutions Design
Exhibit: You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to se...
path managementVLANsSLMmultipath - Question #34ONTAP SAN Solutions Design
You are planning to implement a 32 Gb FC SAN on a 2-node AFF A700 ONTAP 9.5 cluster. You need to create 112 FC LIFs across the HA pair with a limit of 20 FC LIFs per physical HBA p...
FC LIF planningHBA sizingcapacity planning32Gb FC - Question #35ONTAP SAN Solutions Troubleshooting
Exhibit: Referring to the exhibit, you have SAN LUNs on an AFF A700s and are asked to test an SSD shelf stack failure. What is the maximum allowed number of failed paths per contro...
storage failovershelf stack failurepath redundancyAFF A700s - Question #36ONTAP SAN Solutions Management
You have an SVM that serves LUNs to your hosts in an FC SAN environment. This SVM runs on a 4- node cluster and has two data LIFs on each node, according to best practices. You jus...
LUN moveLUN mobilitySAN testingFC SAN - Question #37ONTAP SAN Solutions Troubleshooting
While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed: What is the cause of this error?
LUN expansionvolume auto-growLUN capacityerror diagnosis - Question #38ONTAP SAN Solutions Implementation
Exhibit: You have a LUN owned by Node 01 and mapped using the default Selective LUN Map (SLM) configuration. You want to enable your host to access this LUN and facilitate future m...
FC zoningSLMbest practiceszone configuration - Question #39ONTAP SAN Solutions Implementation
Which path selection policy is used by Windows Servers using NetApp LUNs that are greater than 2 TB?
path selection policyWindows MPIOlarge LUNsround robin - Question #40ONTAP SAN Solutions Design
Which two are supported in ONTAP 9.5? (Choose two.)
NVMeLIF configurationSVM configurationNVMe/FC - Question #41ONTAP SAN Solutions Troubleshooting
An administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance...
VSCigroupdatastore provisioninghost access - Question #42ONTAP SAN Solutions Implementation
An administrator is configuring a SAN-only cluster. The data room that houses four AFF A220 controllers is small and not able to house the DS224C shelves. The administrator propose...
cablingactive optical cablesshelf connectivitydistance requirements - Question #43ONTAP SAN Solutions Implementation
Which three components are required for NetApp iSCSI LUN access on Linux servers? (Choose three.)
iSCSILinux hosthost utilitiesmultipath - Question #44ONTAP SAN Solutions Management
An administrator has a new AFF A220 system with two DS224C disk shelves and wants to validate if the shelf cabling is correct. Which resource would be used to accomplish this task?
Config Advisorshelf cabling validationhardware configurationtroubleshooting tools - Question #45ONTAP SAN Solutions Design
You currently have a FAS8200 with ONTAP 9.5. You want to expand the front end FC I/O capabilities. However, you are unsure which target adapters are supported. What would you use t...
Hardware UniverseFC adapterscompatibilityFAS8200 - Question #46ONTAP SAN Solutions Management
Exhibit: Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.)
NVMe namespacededuplicationcompressionstorage efficiency - Question #47ONTAP SAN Solutions Management
Exhibit: You have a performance critical database application that is running on a FAS9000 controller that uses FC. As shown in the exhibit, volume efficiency is enabled. If you fo...
volume efficiencyperformance optimizationcompressionstorage efficiency - Question #48
You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches. In this scenario, whic...
- Question #49ONTAP SAN Solutions Troubleshooting
Exhibit: You connected your FAS8200 to a Brocade SAN switch. As shown in the exhibit, port 0e is not available. In this scenario, which statement is correct?
FC port modesE_PortBrocade switchFC fabric login - Question #50ONTAP SAN Solutions Design
An administrator wants to design an NVMe solution to connect Linux hosts to an ONTAP cluster. The proposed solution uses two Cisco MDS 9396T switches for each fabric in a top-of-ra...
NVMe/FCNPIVCisco MDSfabric design - Question #51ONTAP SAN Solutions Implementation
On your ONTAP 9.5 cluster, you need to set up the onboard key manager with hardware-based security and volume encryption. Which two licenses are required in this situation? (Choose...
volume encryptiononboard key managerVE licenseNVE - Question #52ONTAP SAN Solutions Troubleshooting
A customer is planning to connect a Linux server to a FAS8200 using Brocade FC switches. During the initial configuration, the SVM does not log in to the fabric. Which two statemen...
SVM LIF configurationiSCSI VLANbroadcast domainfabric login - Question #54ONTAP SAN Solutions Troubleshooting
Exhibit: Referring to the exhibit, what is the problem with switch port 0?
FC optical diagnosticsSFP receive powerswitch port monitoringfiber optics - Question #55ONTAP SAN Solutions Management
An administrator has expanded a 2-node ONTAP cluster to a 4-node ONTAP cluster. The cluster is using FC LUNs with all of the default settings. You must rebalance the LUNs to the ne...
SLM reporting nodescluster expansionLUN rebalancingFC LUN management