NS0-175 Exam Questions
60 real NS0-175 exam questions with expert-verified answers and explanations. Page 1 of 2.
- Question #1FlexPod Design Methodologies
You are designing a FlexPod solution with secure multitenancy for a company. Each department in the company wants to use their own storage and to be integrated with Windows Active...
secure multitenancySVMCIFSActive Directory - Question #2Cisco UCS Compute Design
Which Cisco UCS Fabric Interconnect model has multiple 100 Gbps ports available for use?
Fabric InterconnectUCS 6454100GbE - Question #3Data Center Integration and Validation
You want to ass a customer's NetApp storage controllers into their Cisco Intersight management portal. In this scenario, which IP address would you choose to add?
Cisco IntersightActive IQ Unified Managermanagement integration - Question #4FlexPod Solution Components and Architecture
You want to direct-connect NetApp storage to a UCS Mini over IP. In this scenario, which storage protocol is supported?
UCS Minidirect connectstorage protocolFC - Question #5NetApp Storage Design
You are designing a FlexPod solution that requires 100GbE connectivity between all components. In this scenario, what are two NetApp Controller types that would satisfy the require...
100GbEAFF A220AFF A400NetApp controllers - Question #6FlexPod Design Methodologies
A customer wants a FlexPod solution that is designed for high performance applications and that will support 32 Gbps Fibre Channel block storage. In this scenario, which two compon...
32 Gbps FCAFF A800Nexus 93180YC-FXblock storage - Question #7NetApp Storage Design
A customer is designing a FlexPod solution that must satisfy the requirements shown below: have disaster recovery to an alternative data center, must have continuous replication of...
MetroClusterdisaster recoverydistance constraintsdata replication - Question #8Data Center Integration and Validation
A customer has decided to deploy Red Hat OpenShift on a FlexPod solution, based in a published Cisco Validated Design. The customer intends to use the NetApp Trident to attach pers...
NetApp TridentOpenShiftpersistent storagestorage protocols - Question #9Cisco Networking Design
You are asked to ensure link redundancy to your hosts using Virtual Port Channel (vPC). You are creating a vPC on a pair of Cisco Nexus switches. In this scenario, which two steps...
vPCNexuspeer keep-alivelink redundancy - Question #10Cisco Networking Design
A partner wants to develop a FlexPod Datacenter solution for a customer that will use Cisco ACI. In contrast to a FlexPod solution with NX-OS, which two additional requirements mus...
Cisco ACIAPICleaf-spine topologyNX-OS - Question #11Cisco Networking Design
You have designed a FlexPod configuration with VXLAN configured on Cisco Nexus 9000 Series switches operating in NX-OS mode. Which two statements are true in this scenario? (Choose...
VXLANNexus 9000NX-OSoverlay networking - Question #12Cisco UCS Compute Design
You are creating a FlexPod with a significant AI workload and would like to use NVIDIA's SXM2- based GPUs. Which Cisco UCS server would you use in this scenario?
GPUNVIDIA SXM2AI workloadUCS C480 ML M5 - Question #13Cisco UCS Compute Design
A customer has a workload that requires an extremely dense deployment of CPU cores. For this workload, they have chosen to deploy servers that use AMD EPYC processors. Which Cisco...
AMD EPYCCPU densityUCS C125 M5 - Question #14Cisco UCS Compute Design
A customer deployed a FlexPod Datacenter solution six months ago that included Cisco UCS 6332 Fabric Interconnects with the default port license enabled. They will be performing an...
UCS 6332port licenseFabric Interconnectdefault license - Question #15FlexPod Solution Components and Architecture
You are working with a customer on a new FlexPod solution. The customer advises you that they want a single point of contact for support issues. In this scenario, which two support...
FlexPod supportSmartNetNetApp Solution Supportsingle point of contact - Question #16FlexPod Design Methodologies
A customer wants to deploy a FlexPod Datacenter solution that supports a secure multitenant design with VMware vSphere 6.x as the hypervisor. The customer wants to ensure that virt...
VM encryptionNetApp Storage Encryptionsecure multitenancydata security - Question #17Cisco Networking Design
A customer has a FlexPod configuration that supports FC and uses Cisco MDS switches. The customer wants to add a 48-Port 32 Gbps Advanced Fibre Channel Switching blade to support b...
Cisco MDS32 Gbps FCNVMe-oFFC switching blade - Question #18FlexPod Solution Components and Architecture
Which two support account levels are minimally required when you deploy a FlexPod Datacenter solution? (Choose two.)
support levelsSupportEdge AdvisorCisco Solution SupportFlexPod support - Question #19FlexPod Solution Components and Architecture
What are the 1U, rack mountable, Fabric Extenders (FEX) used for in a FlexPod environment?
Fabric ExtenderFEXUCS C-SeriesFabric Interconnect - Question #20FlexPod Solution Components and Architecture
Which three cables are allowed to be used between a NetApp cluster node and a Nexus switch for use with a port channel? (Choose three.)
port channelcable typesAOCTwinax - Question #21FlexPod Solution Components and Architecture
A customer wants to add 40 Gbps networking capabilities to a FlexPod Datacenter 10 Gbps environment. Which two Cisco components support this speed? (Choose two.)
40GbE networkingCisco Nexus 9504Cisco UCS VIC 1400FlexPod upgrade - Question #22ONTAP SAN planning and implementation
You are building a new FlexPod system booting from SAN. Referring to the exhibit, how many paths will there be to the target LUN?
SAN bootFC path countLUN accessmultipathing - Question #23Cisco Networking Design
You are asked to design a new FlexPod solution that will host VMware virtual machines using NFS datastores, file services using SMB, and NFS-mounted home directories. You need to e...
VLAN isolationvPCNFS datastorenetwork traffic segmentation - Question #24FlexPod Design Methodologies
You received from a customer the requirements shown below. 25 servers 25GbE connectivity NFS and iSCSI protocols 30 TB flash storage 50 TB hybrid storage In this scenario, which Fl...
FlexPod sizing25GbECisco UCS 6332component selection - Question #25Data Center Integration and Validation
A customer wants to upgrade their current VMware vSphere 6.5 environment to vSphere 7.x. Where would you go to determine which Cisco UCS configurations support this goal?
VMware vSphere compatibilityCisco UCS HCLupgrade planninginteroperability - Question #26ONTAP SAN planning and implementation
A customer wants a low latency and high IOPS FlexPod solution and decides on an end-to-end NVMe design. In this scenario, which three components are required to accomplish this tas...
NVMe end-to-end32Gbps FC HBACisco MDSUCS VIC 1400 - Question #27NetApp Storage Design
A customer with a FlexPod solution wants to expand their NetApp ONTAP 9.7 switchless cluster. The new hardware must support expansion slots. In addition, they will also upgrade to...
cluster interconnect switchswitchless cluster expansionNexus 3232C100GbE - Question #28NetApp Storage Design
An administrator is designing a FlexPod solution with NetApp ONTAP 9.7 software with a logical separation of data for each department. In this scenario, which two components must b...
IPspacesStorage Virtual Machinesdata isolationONTAP multi-tenancy - Question #29ONTAP SAN planning and implementation
Your customer wants to change from local boot to SAN boot for the compute layer. What must be present on the network layer to meet the customer's design change?
SAN bootFC protocolnetwork layer requirementsboot from SAN - Question #30Cisco UCS Compute Design
You want to ensure the uniqueness of the Cisco UCS WWNNs and WWPNs in the SAN for a FlexPod solution. In this situation, Cisco recommends using which WWN prefix for all blocks in a...
WWN prefixWWNNWWPNCisco UCS SAN pool - Question #31Cisco UCS Compute Design
A customer wants to replace their Cisco UCS 6248UP with the current Cisco UCS 6454. They are currently using six 16 Gbit uplinks per Fabric Interconnect for FC and do not want to c...
Cisco UCS 6454fabric interconnect upgradeFC unified portsport configuration - Question #32ONTAP SAN management
An administrator wants to ensure secure authentication while accessing a NetApp ONTAP system. In this scenario, which two access methods should be used? (Choose two.)
ONTAP authenticationSSHHTTPSsecure management access - Question #33NetApp Storage Design
During a design meeting, a customer states that their goal is to deliver continuous availability across both network and storage during business continuity events. The customer has...
MetroCluster IPbusiness continuitystretched clusterdata protection - Question #34FlexPod Design Methodologies
A customer has reviewed the latest vSphere CVD and asks you if they can use their older Cisco servers in the new FlexPod solution and still have supported configuration. Which stat...
CVD complianceFlexPod support policyvalidated designhardware compatibility - Question #35Data Center Integration and Validation
You have taken over management of an existing FlexPod system as part of a new job role. You want to find details of existing support and service contracts available for the system....
support contractsCisco Device Coverage CheckerNetApp supportlifecycle management - Question #36FlexPod Design Methodologies
You are sizing a FlexPod Datacenter solution for multitenancy use. What are two important platform scaling considerations in this scenario? (Choose two.)
multitenancyONTAP cluster limitsstorage VM limitsplatform scaling - Question #37NetApp Storage Design
You are developing a FlexPod solution with a MetroCluster IP as the storage solution. In this scenario, which two components are supported? (Choose two.)
MetroCluster IPAFF A400Cisco Nexus 3232Csupported components - Question #38Data Center Integration and Validation
You are asked to evaluate SaaS-based monitoring solutions for your FlexPod environment. Other than being SaaS-delivered, selection criteria include full lifecycle management, envir...
SaaS monitoringNetApp Cloud Insightslifecycle managementthird-party storage - Question #39Cisco Networking Design
A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their F...
Nexus 93180YC-FXFC SAN bootMDS-less SANdirect-connect storage - Question #40NetApp Storage Design
You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environme...
MetroCluster IP switch requirementsQoSjumbo frames MTU 9216multi-site FlexPod - Question #41Cisco UCS Compute Design
You are sizing a FlexPod Virtual Desktop solution for a customer with 500 virtual desktops in a shared Remote Desktop Services (RDS) topology. In this scenario, which Cisco best pr...
VDI sizingRDS topologyCPU overcommitvirtual desktop - Question #42FlexPod Solution Components and Architecture
You have a FlexPod solution that consists of a NetApp AFF A800 storage system, a Cisco MDS 9148S switch, and a Cisco UCS 6232 Fabric Interconnect. You want to upgrade NetApp ONTAP...
ONTAP upgradeinteroperability matrixIntersightupgrade advisor - Question #43Cisco Networking Design
You are designing a new FlexPod solution to use with VMware vSphere by using NFS datastores and want to ensure maximum availability by using a vPC. In this scenario, on which Cisco...
vPCNFS datastoreVMware vSphereNexus switch - Question #44FlexPod Solution Components and Architecture
What are three requirements for all FlexPod Datacenter solutions? (Choose three.)
FlexPod requirementsfabric interconnectFEX redundancyboot-from-SAN - Question #45Cisco UCS Compute Design
A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they...
rack densityblade serverUCS chassisserver sizing - Question #46Cisco Networking Design
A customer wants to refresh their FlexPod solution by moving from 10 Gbps to 40 Gbps networking. They use FCoE to boot from SAN. In this scenario, which statement is true?
FCoE40 Gbpsnetwork upgradeunified fabric - Question #47Cisco UCS Compute Design
You want to use Cisco UCS Manager on the Fabric Interconnects to manage attached C-Series servers. Which two connection topologies would satisfy the requirements? (Choose two.)
UCS ManagerC-Series integrationfabric interconnectconnection topology - Question #48FlexPod Solution Components and Architecture
A customer wants to deploy Cisco Intersight into their FlexPod environment. The customer is using the Cisco Intersight SaaS model. In this scenario, which two virtual machines are...
Cisco IntersightSaaS modelvirtual appliancemanagement platform - Question #49FlexPod Solution Components and Architecture
In which two sources would you verify scale out maximums for NetApp and Cisco UCS environments? (Choose two.)
scale limitsHardware Universecompatibility listcapacity planning - Question #50Cisco UCS Compute Design
A customer is performing a server refresh of their FlexPod solution to accommodate business growth. The customer is interested in using Cisco C-Series servers, and supporting multi...
VIC adapter40 GbpsC-Seriesnetwork adapter selection