E20-611 Exam Questions
397 real E20-611 exam questions with expert-verified answers and explanations. Page 5 of 8.
- Question #210
Company.com has ordered disk drives of different speeds and capacity to be installed in a DAE3P. Which disks should be installed in the lowest numbered slots in the chassis?
- Question #211
Which "Magic Byte" is used for all RAID types and detects any errors in a sector?
- Question #212
Which utility outputs are used by SWAT to analyze switches?
- Question #213
On a CLARiiON array, which cache type is required to achieve optimal host data flow performance?
- Question #214
Which storage processor port is identified by WWPN 50:06:01:61:90:60:05:e4?
- Question #215
After installing a CLARiiON management station, EMCRemote is unable to communicate with the SP. What is the most likely reason?
- Question #216
Which host-based tool provides a graphical representation of read link services (RLS) statistics?
- Question #217
Why is the Non-Disruptive Upgrade delay required?
- Question #218
Which IP address is displayed for SPB in an uninitialized CLARiiON CX3 series array?
- Question #219
Why would Company.com Engineer use the Prepare for Installation Wizard?
- Question #220
Which statement accurately describes recovery using Non-Disruptive Bind?
- Question #221
How many power supplies must be present to maintain Write caching?
- Question #222
What is the EMCRemote requirement in a Centralized Monitoring eMail Home for Windows Workstation configuration?
- Question #223
Which two applications are needed to run the Off-Array Management GUI?
- Question #224
Which type of connector is used to connect to the serial port on a CLARiiON CX500?
- Question #225
What is the SPB Service LAN port IP address in a CLARiiON CX3-40c?
- Question #226
What are the output file extensions for FBI and for SPLAT?
- Question #227
How many gigabytes of user space are available in a non-vault 73 GB disk drive?
- Question #228
Which syntax switch is the same as -address in Navisphere Secure CLI?
- Question #229
What is a primary purpose of the supportShow command?
- Question #230
Company.com has a CLARiiON CX700 setup with eight heterogeneous non-clustered hosts. Each host is connected to a single HBA . What are the available topologies for the customer's e...
- Question #231
In a heterogeneous environment, which actions will occur when Access Control is disabled on an already configured array?
- Question #232
Prior to performing an NDU, which utility will obtain the information required to verify the array status, NDU readiness, and the HA status for attached hosts?
- Question #233
Before release 19, what is the correct command format for Sniffer?
- Question #234
Where in the Navisphere Manager GUI would you verify that the page size is set to 8k?
- Question #235
What is the maximum cable length between the SPEs and the DAEs for a CLARiiON CX3 platform?
- Question #236
A Windows server has PowerPath installed. What should be the correct failover setting?
- Question #237
What does the term "write aside" refer to in a CLARiiON array?
- Question #238
What is one way to install a recovery image in the image repository?
- Question #239
Company.com has a CLARiiON CX700 connected with four heterogeneous hosts. Each host has two HBAs connected to the array for high availability and has Access Logix installed. Which...
- Question #240
What is the EMCRemote requirement in a Centralized Monitoring eMail Home with a WebEx configuration?
- Question #241
A CLARiiON CX3 array has 15 FC 146 GB drives, 10 FC 300 GB drives, and 15 ATA 320 GB drives. What is the minimum number of hot spares that should be configured?
- Question #242
In a CLARiiON CX3 series array, what is the minimum number of disks in a RAID 1/0 group?
- Question #243
Which three switches are supported by the SWAT utility?
- Question #244
When accessing the array through the Navisphere GUI, when is it necessary to be connected to the domain master?
- Question #245
Where is the output of EMCReports stored after running it on a host server?
- Question #246
Company.com Engineer needs to assign a LUN to more than one storage group. Which option under Show LUNs is used?
- Question #247
As represented in the exhibit, Disk 2 has failed. The storage processor reads Blocks 1, 2, 4 and Parity 1-4 from the remaining disks in the RAID group (0, 1, 3, and 4). With this i...
- Question #248
What is the process of copying data from a hot spare to a replacement disk in CLARiiON arrays?
- Question #249
What is the maximum number of disk drives supported on each back-end loop of a CLARiiON CX3-80 array?
- Question #250
What is the range of the Non-Disruptive Upgrade (NDU) delay time?
- Question #251
Company.com Engineer is sent to Company.com site to replace an Array Management Module for a CLARiiON CX3-80. Where is the Management Module for SPA located?
- Question #252
Which type of connection exists between an ATA DAE2 midplane and the disk drive?
- Question #253
What does release 19 add to the Navisphere GUI?
- Question #254
Which interface is recommended when using the host-based FBI to monitor a FC4700 Array?
- Question #255
Where is the Utility Partition for SPA?
- Question #256
Which two items are contained in SP Collect?
- Question #257
Where do you verify that LUN masking is enabled in Navisphere Manager on a CX500?
- Question #258
What is the process of reconstructing data for a faulted disk and writing the data to a hot spare in CLARiiON arrays?
- Question #259
You are setting up a Windows CLARiiON management station at Release 19. Which version of JAVA should be installed?