NS0-521 Exam Questions
122 real NS0-521 exam questions with expert-verified answers and explanations. Page 1 of 3.
- Question #1ONTAP SAN Solutions Design
What connectivity Is required between NetApp ONTAP clusters in order to configure SnapMirror active sync across two data centers for FC?
SnapMirror active synccluster peeringFC connectivitydata center - Question #2ONTAP SAN Solutions Design
What is the minimum number of rack units that are required on each site for a NetApp AFF All San Array (ASA) A800 MetroCluster IP configuration with 72 disks per site and Cisco N9K...
MetroCluster IPASA A800rack unitshardware sizing - Question #3ONTAP SAN Solutions Management
What Is modified when moving a LUN between different HA pairs in the same SVM to prevent loss of connectivity?
LUN migrationreporting nodesHA pairsSVM - Question #4ONTAP SAN Solutions Implementation
A customer has created an SVM for their SAN workloads. They now want to configure the SVM to use NVMe/FC. Which two steps are needed to accomplish this task? (Choose two.)
NVMe/FCSVM configurationFC protocolNVMe LIF - Question #5ONTAP SAN Solutions Management
A storage administrator wants to increase security and optimize performance in a recently implemented SAN deployment. What should the storage administrator configure to ensure init...
LIF access controlinitiator restrictioniSCSI securityaccess list - Question #6ONTAP SAN Solutions Troubleshooting
A LUN Is displaying 90% used space in the NetApp ONTAP CLI, but a Windows Server shows only 10% used space. What is the first step to take to address this issue?
space allocationLUN space reportingthin provisioningWindows host - Question #7ONTAP SAN Solutions Implementation
A storage administrator recently implemented ISCSI SAN in a customer environment. Which two actions should be done to ensure the best performance? (Choose two.)
iSCSI performanceJumbo framesswitch topologyqueue depth - Question #8ONTAP SAN Solutions Implementation
An administrator is configuring ISCSI on an SVM and requires that all network traffic Is encrypted. What must be done to satisfy this requirement?
iSCSI encryptionIPsecnetwork securitySVM - Question #9ONTAP SAN Solutions Design
What Is a recommended setting for using the NetApp ONTAP LUN fractional reserve?
fractional reservespace guaranteeLUN space reservationvolume - Question #10ONTAP SAN Solutions Implementation
A customer has data in a LUN on an existing third-party SAN storage system that will be migrated to a new NetApp AFF A400 all-flash MetroCluster system. The host connected to the L...
Foreign LUN Importdata migrationFLI offlinethird-party SAN - Question #11ONTAP SAN Solutions Management
What needs to be done to create a consistent Snapshot copy of a LUN without disruptions?
LUN snapshotI/O quiescecrash-consistent copydata protection - Question #12ONTAP SAN Solutions Management
An administrator has a NetApp AFF cluster supporting an application with twelve LUNs allocated across four volumes. There is a requirement to configure a Snapshot copy of all LUNs...
consistency groupsimultaneous snapshotmulti-volume LUNvserver CLI - Question #13ONTAP SAN Solutions Management
A customer asks for help cloning one database LUN from a SnapMirror destination volume for testing the data with a new application. What command should the administrator use to clo...
LUN cloningSnapMirror destinationvolume cloneFlexClone - Question #14ONTAP SAN Solutions Troubleshooting
A customer has a 10GB volume with an 8GB LUN that is using 7GB. The snapshot policy is hourly and retains 48 snapshots. After a ransomware attack that encrypts all files on the LUN...
snapshot autodeleteransomware recoveryspace managementvolume overcommit - Question #15ONTAP SAN Solutions Management
A customer currently operates a legacy iSCSI storage environment that is connected to network switches with several Windows hosts. As part of an upcoming NetApp ONTAP software upgr...
IMTActive IQ OneCollectiSCSI compatibilityONTAP upgrade - Question #16ONTAP SAN Solutions Management
A storage engineer in SAN environment needs to Identify FC ports using the company-wide naming policy. Which command will accomplish this task?
FC WWPN aliasport naming policyFCPSVM CLI - Question #17ONTAP SAN Solutions Design
When using FCP, what is the minimum number of FC switches needed to redundantly attach three ESXi hosts?
FC switch redundancyFCP fabric designESXi connectivitySAN topology - Question #18ONTAP SAN Solutions Management
An administrator creates a new volume and a LUN for an SAN-connected application that uses snapshots. The application has fast-growing data that is constantly being populated and d...
volume auto-resizespace managementLUN snapshotsthin provisioning - Question #19ONTAP SAN Solutions Implementation
A site survey has been conducted for an installation of a switchless HA pair with two NetApp DS224C shelves in the customer's already populated rack. Which of the following two nee...
switchless HA pairDS224C shelfrack unitspower connections - Question #20ONTAP SAN Solutions Troubleshooting
A customer opens a support case for performance issues with an FC Oracle database after migrating from a NetApp AFF system to a NetApp All SAN Array (ASA) platform. Further investi...
Selective LUN Mappingpath managementFC zoningASA platform - Question #21ONTAP SAN Solutions Design
A customer Is deploying a new 8-node NetApp ONTAP cluster for their SAN workloads using FCP, NVMe/FC, and NVMe/TCP. In this scenario, which statement is true?
NVMe/FCFCPNVMe/TCPprotocol coexistence - Question #22ONTAP SAN Solutions Management
Which feature enables simultaneous snapshots of multiple LUNs In different volumes?
consistency groupssnapshotsLUNsdata protection - Question #23ONTAP SAN Solutions Management
A storage administrator has a NetApp AFF SAN cluster in a multitenant environment. Another user has requested access to perform only replication within a specific SVM to another cl...
RBACvsadmin-backupSVM rolesmultitenancy - Question #24ONTAP SAN Solutions Management
What should an administrator use to protect an Oracle RAC Automatic Storage Management (ASM) instance to ensure automated restores?
Oracle RACASMSnapCenterapplication integration - Question #25ONTAP SAN Solutions Implementation
What is the storage construct that enables an NVMe client to store data in an SVM?
NVMesubsystemnamespaceSVM storage construct - Question #26ONTAP SAN Solutions Implementation
An administrator finishes an installation of a new NetApp ASA system at the customer site and creates a new LUN. The customer wants to restrict the access of the LUN to specific UF...
Selective LUN MapLUN access controlASAigroup - Question #27ONTAP SAN Solutions Implementation
A customer wants to enable CHAP authentication on their iSCSI sessions. Which command should be used to set up the appropriate security policies and passwords?
CHAP authenticationiSCSI securityvserver iscsi securityCLI commands - Question #28ONTAP SAN Solutions Management
Which two steps must be taken first to restore a LUN from a SnapMirror Synchronous destination? (Choose two.)
SnapMirror SynchronousLUN restorerelationship managementdata recovery - Question #29ONTAP SAN Solutions Troubleshooting
An administrator configured an SVM with LUNs with two WWPNs per node. The administrator accidentally created a WWPN on node1 that needs to move to node2. The SAN hosts use ALUA. Ba...
WWPNLIFALUAFCP troubleshooting - Question #30ONTAP SAN Solutions Implementation
A customer is setting up a four-node NetApp cluster for use with NVMe/TCP and wants to use automatic host discovery. Which protocol is used for the discovery of controllers?
NVMe/TCPmDNScontroller discoveryhost connectivity - Question #31ONTAP SAN Solutions Management
An administrator upgraded their NetApp ONTAP software from release 9.10.1 to 9.13.1 on a NetApp All SAN Array (ASA) cluster and is creating a new iSCSI SVM. Which automatic feature...
iSCSILIF failoverASAONTAP upgrade - Question #32ONTAP SAN Solutions Implementation
An SVM is created for FCP traffic. LUNs must be created to share with ESXi hosts for datastores. Which two items must be configured after the LUN is created, for this to happen? (C...
FCPigroupLUN mappingESXi datastores - Question #33ONTAP SAN Solutions Design
An administrator needs to ensure that Snapshot copies of database files across multiple FCP LUNs are taken at the same point in time. Which two configurations enable the administra...
consistency groupscrash-consistent snapshotsFlexVoldatabase protection - Question #34ONTAP SAN Solutions Design
Which two NetApp features provide synchronous data replication between two sites for SAN workloads with automatic failover in case of a site disaster? (Choose two.)
SnapMirror active syncMetroCluster IPsynchronous replicationautomatic failover - Question #35ONTAP SAN Solutions Management
An administrator runs the vserver nvme namespace convert-from-iun command on a NetApp ASA cluster to increase host performance. What is modified by the convert command?
NVMe namespaceLUN conversionASAmetadata - Question #36ONTAP SAN Solutions Design
What is the maximum size for a LUN in NetApp ONTAP 9.14.1 software?
LUN size limitsONTAP 9.14.1capacity planningstorage specifications - Question #37ONTAP SAN Solutions Implementation
How should host systems be configured to optimize SAN utilization and efficiency? (Choose Two)
HBA queue depthmultipathinghost optimizationSAN host configuration - Question #38ONTAP SAN Solutions Design
In the context of SAN switches, what configurations are important for ensuring high performance and availability? (Choose Two)
SAN switchesredundant pathsport zoningFC fabric design - Question #39ONTAP SAN Solutions Implementation
Which tasks are essential for SVM configuration? (Choose Three.)
SVM configurationresource limitsstorage efficiencynetwork protocols - Question #40ONTAP SAN Solutions Management
During data migration, what is a key factor to ensure data integrity?
data migrationdata integritydata verificationmigration best practices - Question #41ONTAP SAN Solutions Design
Why must SAN solutions designers consider future scalability when designing systems?
scalabilitySAN designcapacity planningfuture growth - Question #42ONTAP SAN Solutions Design
Which factor is critical when inventorying SAN components for a new installation?
component inventoryinteroperabilitycompatibilitySAN installation - Question #43ONTAP SAN Solutions Design
Why is it crucial to evaluate environmental factors before deploying SAN solutions?
environmental factorsphysical conditionsSAN deploymentreliability - Question #44ONTAP SAN Solutions Troubleshooting
What step is essential after performing any troubleshooting task on an ONTAP SAN system?
troubleshooting documentationchange managementpost-resolution steps - Question #45ONTAP SAN Solutions Implementation
How should data migration be approached to minimize downtime in ONTAP SAN environments?
data migrationphased migrationdowntime minimizationONTAP SAN - Question #46ONTAP SAN Solutions Implementation
In the context of ONTAP SAN, which testing task is essential before going live?
pre-production testingload testingfailover simulationSAN validation - Question #47ONTAP SAN Solutions Design
A healthcare customer wants to Implement an FC SAN solution consisting of a NetApp ONTAP system, Broadcom switches, and servers. Which tool contains detailed blueprints and impleme...
NetApp Verified ArchitectureFC SAN designreference architectureBroadcom switches - Question #48ONTAP SAN Solutions Implementation
An administrator is setting up a NetApp ONTAP AFF system for both NVMe/TCP and iSCSI. Which task is required for SAN configuration?
NVMe/TCPiSCSILIF configurationSAN setup - Question #49ONTAP SAN Solutions Design
What are two benefits of implementing VLANs for NVMe/TCP configurations? (Choose two.)
VLANsNVMe/TCPnetwork segmentationsecurity - Question #50ONTAP SAN Solutions Implementation
A customer wants to configure an NVMe protocol-based NetApp ONTAP based storage system in a SAN environment. What is used to configure the list of hosts?
NVMesubsystemhost mappingnamespace