H31-341_V2.5 Exam Questions
997 real H31-341_V2.5 exam questions with expert-verified answers and explanations. Page 20 of 20.
- Question #951
If the cumulative amount of dispersion exceeds the system's dispersion tolerance, it will cause bit errors at the receiving end.
- Question #952
When R_LOS, RLOF, R_OOF, MUT_LOS and other alarms appear on the device, it means that the service has been interrupted.
- Question #953
Flex grid technology can flexibly adjust the center frequency of the liquid length by adjusting the occupied slice position.
- Question #954
The receiving sensitivity of a certain optical monitoring board is -48dBm. When the input optical power is -5dBm, it meets the requirements of the optical power receiving range.
- Question #955
If there is only a single channel interval, automatically plan the allocation from short wavelength to long wavelength according to the default channel.
- Question #956OTN System Principles and Networking
The MOTUm interface completes the ODUPM overhead encapsulation before the ODUK-TCM encapsulation in the sending sea?
OTN Encapsulation OrderMOTUm InterfaceODUPM OverheadODUK-TCM - Question #957OTN System Principles and Networking
Only one TCM can be used at the same site
TCM (Tandem Connection Monitoring)multi-TCM configurationOTN system capabilitiessite deployment architecture - Question #958Transmission Network Operations and Maintenance
The setting of alarm reversal is port-based.
alarm reversalport-based configurationalarm managementnetwork operations - Question #959Transmission Network Operations and Maintenance
The CLASS 1M mark on the optical module indicates that the luminous power is low and will not cause damage to eyes or skin.
CLASS 1M laser safetyoptical module classificationlaser hazard standardseye/skin safety - Question #960OTN System Principles and Networking
The use of QPSK modulation can reduce OSNR requirements and fiber nonlinear hazards, improve dispersion tolerance PMD tolerance, etc.
QPSK modulationOSNRFiber nonlinearityDispersion tolerance - Question #961WDM/OTN Planning, Design, and Configuration
The EMR8 board is a fixed multiplexer/demultiplexer board, which can support up to 8 specific discontinuous wavelengths.
EMR8 boardmultiplexer/demultiplexerwavelength configurationOTN equipment - Question #962OTN System Principles and Networking
PWE3, as an end-to-end one-layer service bearing technology, provides a point-to-point L2vP service in the public network, and transmits various services (such as Ethernet and TDM...
PWE3L2VPNPseudowire emulationPSN - Question #963WDM/OTN Planning, Design, and Configuration
In the early stage of the project, the commissioning of the coherent system can properly improve the performance by increasing the transmitted optical power.
Coherent optical systemsSystem commissioningPerformance optimizationOptical power management - Question #964WDM/OTN Planning, Design, and Configuration
For a coherent system, the reference point of the fiber-in optical power in the non-standard fiber- in scenario is the output port of the optical amplifier board at the sending end...
coherent optical transmissionfiber-in configurationoptical amplifierpower reference - Question #965
In the G.652 optical fiber and LEAF optical fiber system, the coherent mixed transmission of super 100G and 100G needs to set up an isolation zone.
- Question #966OTN System Principles and Networking
For the OTN interface without optical layer overhead, in order to achieve the purpose of monitoring, the OTUk/OTUk-v/OTUkV and OTUCn signals are terminated when the interface signa...
OTN Signal TerminationOTUk/OTUCn SignalsNetwork MonitoringOptical Overhead - Question #967
In the scenario where the OTU processes Ethernet service signals, when the client side of the OTU boards at station A and station B are both in non-auto-negotiation mode, the clien...
- Question #968
In the non-converged OTU processing SDH standard signal scenario, both A and B are WDM sites. The client side of the OTU at station A detects an RLOS alarm. The client side of the...
- Question #969
TM20 single board can implement 20 coherent optical signals with different wavelengths to be added and multiplexed into 1 multiplexed optical signal and 1 multiplexed optical signa...
- Question #970
For a system with an optical amplifier, the lower threshold of the received optical power on the wavelength division side of the OTU board (PIN type receiving laser) is the receivi...
- Question #971
The nominal rate of the OTU4 signal is 111 809 973.568 kbit/s, and we generally think that the line rate is about 112G.
- Question #972
The dual-fiber bidirectional wavelength division multiplexing system uses two optical fibers to realize bidirectional optical signal transmission, and the same wavelength cannot be...
- Question #973
The 5A deployment of OptiXtrans DC908 refers to port self-adaptation, fiber self-discovery, fiber self-discovery, wavelength self-configuration, and optical layer self-commissionin...
- Question #974
RDU9 can realize the dynamic and configurable demultiplexing function from any wavelength to any port.
- Question #975
The overall procedure for commissioning optical power of a system without an optical amplifier: adjust in sequence from upstream to downstream according to the flow direction of th...
- Question #976WDM/OTN Planning, Design, and Configuration
For the hybrid transmission system with dispersion compensation, the requirements for the optical power entering the fiber should be consistent with the requirements of the origina...
Dispersion CompensationOptical Power RequirementsHybrid Transmission SystemsSystem Design Consistency - Question #977WDM/OTN Planning, Design, and Configuration
The core device of ROADM is the wavelength selective switch (WSS)
ROADMWavelength Selective SwitchOptical Add-DropWDM Components - Question #978OTN System Principles and Networking
The DH function can be used to count the delay and jitter of service packets
DH functionDelay measurementJitter/Delay variationPerformance monitoring - Question #979OTN System Principles and Networking
Both OTUCn and ODUCn can complete the functions of digital field and channel layer.
OTN layer architectureOTUCn vs ODUCnoptical/digital layerstributary units - Question #980WDM/OTN Planning, Design, and Configuration
When a 80 wave ROADM site uses a TM20 for multiplexing, an ITL board must be configured.
ROADM ConfigurationTM20 MultiplexingITL BoardWDM Hardware - Question #981
Optical fiber and LEAP optical fiber systems, 1006 and 106 mixed transmissions need to set up isolation bands, and only one-sided adjacency is supported, and double-sided adjacency...
- Question #982
The last 256 columns of the OTN frame structure are FEC areas, whose function is forward error correction.
- Question #983
In actual WDM systems, systems with a rate of 10G and below are greatly affected by polarization mode dispersion.
- Question #984
OptiXtrans DC908 can predict faults based on trends and volatility, predict all gradual faults in advance, and realize from passive operation and maintenance to active operation an...
- Question #985
In the Colorless scenario, use the M40V/D40 board for adding and adding waves.
- Question #986
DWSS20 single board can realize 20-dimensional optical signal scheduling
- Question #987
Gain is an important index of fiber amplifier, and its unit is decibel.
- Question #988
The frame structure of the OTUk signal consists of 4 rows and 4080 columns, and the value of k can be an integer of 0 to 6, representing line rates of 1.25G, 2.5G, 10G, 40G, 100G,...
- Question #989
The business path belongs to the network layer data on the network management side. Deleting the path at the network layer will not affect the business.
- Question #990
The fully standardized optical transport unit OTUK is an OTUk frame that fully complies with ITU- T G.709 recommendations, and it has the precise field format, field size and type...
- Question #991
In the process of configuring E-LAN, the MAC address learning mode can be set to SVL and IVL. SVL is independent VLAN learning, and IVL is shared VLAN learning.
- Question #992
Like STP equipment, NG WDM equipment can practice network element configuration on the network management system through pre-configuration.
- Question #993
Once a nonlinear effect occurs, its impact on service signals cannot be repaired. Therefore, the current network's approach to dealing with nonlinear effects is to avoid the occurr...
- Question #994
1+1 optical line protection single-end switching is faster than 1+1 optical line protection double- end switching.
- Question #995
The manual reset at the equipment site is hard reset.
- Question #996
In MRPS protection, when a fault occurs, the Raw label is swapped into a Rap label and switched to the protection channel.
- Question #997
1:3 cross-connection mode needs to add two CXCS cross-connection boards, resulting in fewer supported service slots than 1:1 cross-connection mode by two 11U large slots. Therefore...