- Question #351
The cabinet collector cannot be used for environmental data collection of IT cabinets.
- Question #352
The refrigerant cylinder of Huawei air-cooled air conditioner does not need to be placed upside down on the electronic scale when charging refrigerant.
- Question #353
The ECC800 is the core component of local management of the micro-module, and the access of its southbound components can be extended through the POE bus.
- Question #354
The default management authority user name of the ECC800 is admin, and admin has all the authority to operate the WEB interface functions.
- Question #355
Users can monitor the status of equipment such as UPS and air conditioners on the ECC800.
- Question #356
The UPS2000-G-(6-20KVA) does not report a fault but the load is powered off, which may be caused by the poor connection of the output cable.
- Question #357
If the UPS500E-400KVA is equipped with an IP21 configuration, the top outlet is not supported.
- Question #358
When the UPS5000-E is equipped with IP21 components, the top air components can also be installed at the same time.
- Question #359
Before the battery is installed, the open circuit voltage of a single battery is required: 12V battery ≥ 12 60V or 2V TV ≥ 2 10V, when it is found to be unqualified, the battery ne...
- Question #360
When calculating the battery capacity, the battery discharge capacity system at different backup time is the same.
- Question #361
The NETCol5000-A36W air conditioner has a light load initial function.
- Question #362
BCB-BOX is an optional part of UPS5000-E, used for connection control between battery pack and UPS system, with overload, short circuit protection and remote management tripping fu...
- Question #363
When a single machine is working, after the UPS2000-G machine classification power-off function is disabled, the PL port has no output when it is overloaded or the battery voltage...
- Question #364
The closed hot and cold aisle system can improve cooling efficiency and reduce energy consumption.
- Question #365
The two ECMs of the UPS5000-E do not support active/standby switchover.
- Question #366
ECC800 does not support historical data export.
- Question #367
The cycle life of a battery is proportional to the depth of discharge.
- Question #368
PDU8000 precision power distribution cabinet supports the monitoring of main circuit phase current, active power, electric energy and branch circuit switch status.
- Question #369
The UPS5000-E (50kVA power module) has a single cabinet capacity of 300kVA and can support 8 racks in parallel.
- Question #370
The NetEco management system supports user decentralization and domain division, so that different operation and maintenance personnel can only view the devices they manage. For ex...
- Question #371
The FusionModule800 does not need to be charged with refrigerant on site within 30m of the connecting pipe.
- Question #372
A single row of FusionModule 2000 supports a maximum of 48 cabinets.
- Question #373
In the UPS5000 configuration, different battery schemes can be obtained by adjusting the number of battery strings and the number of battery cells in a single group.
- Question #374
The PDU8000 precision power distribution cabinet supports the monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.
- Question #375
In the UPS5000 configuration, the power supply reliability level cannot be selected.
- Question #376
FusionModule800 has the function of self-starting of civil air conditioners.
- Question #377
The bypass module of UPS5000-E-200K (50kVW power module) is the same as that of UPS5000-E-300K.
- Question #378
FusionModule800 can only support down pipe.
- Question #379
The NetEco6000 management system supports virtualized deployment and adapts to the rhythm of future cloudification.
- Question #380
FusionModule800 version 3.0 supports face recognition function.
- Question #381
APM, NR and other UPS products need to be derated at 30 degrees, and UPS5000-E does not need to be below 40 degrees.
- Question #382
The UPS5000-E (25-75kVA) bypass module has a maximum output power of 128kW.
- Question #383
FusionModule800 3.0 closed channel hot and cold channels are optional.
- Question #384
In the FusionModule2000 single-row cabinet scenario, the configuration of sliding doors/electric doors is not supported.
- Question #385
UPS5000-A supports the adjustable number of battery cells, which avoids the replacement of a whole group caused by a single battery failure, and solves the problem of difficult mai...
- Question #386
AHU is the smallest module of 220kW under standard conditions and cannot be split.
- Question #387
The access control management function of the Netco6000 management system only supports one-way card swiping (you need to swipe your card to enter the door, and press the exit butt...
- Question #388
UPS5000-S has the function of adjusting the number of battery cells, which avoids the replacement of the whole group caused by the failure of a single battery, and solves the probl...
- Question #389
Temperature cloud map intelligence displayed in NetEco.
- Question #390
The power systems of FusionModule800 and FusionModule500 are 380/400/415/3Ph/50Hz and 220/230/240/1Ph/50Hz respectively.
- Question #391
The height of the FusionModule500&FusionModule800 cabinet is 24U, and both 42U are optional.
- Question #392
UPS5000-A has built-in SNMP and ModBus card, which reduces the management investment cost of customers.
- Question #393
The static load of the FusionModule2000 cabinet can support 2400KG.
- Question #394
UPS5000-E (50kVA power module) single rack can accommodate up to 300kVA.
- Question #395
The bypass module of the UPS5000-E-200K is the same as the bypass module of the UPS5000-E-400K.
- Question #396
NetCol5000-c row-level chilled water intelligent temperature control product has a light-load dehumidification function, which can meet the reliable dehumidification under a minimu...
- Question #397
The UPS5000-E has no built-in transformer.
- Question #398
Fusionlodule500 uses natural heat dissipation.
- Question #399
When selecting to support only temperature detection and not to support hot-plug configuration, the switches in the slot must be fully configured.
- Question #400
The row-level air conditioners (25kw and 42kw) of Huawei FusionModule2000 v3.0 have the refrigerant detection function.