H12-411_V2.0 Exam Questions
656 real H12-411_V2.0 exam questions with expert-verified answers and explanations. Page 7 of 14.
- Question #301
FusinoModule500 adopts natural heat dissipation.
- Question #302
When configuring UPS cables, it is necessary to consider the UPS rated current and the voltage drop on the line for selection.
- Question #303
The maximum output power of UPS5000-E (25-75KVA) bypass module is 128KW.
- Question #304
In the low-voltage power distribution system, the function of the N line is to return the AC working current.
- Question #305
When it is necessary to stop the running equipment, directly disconnect the isolating switch to cut off the power supply of the equipment.
- Question #306
The refrigeration performance of the environmentally friendly refrigerant R410A is better than that of the non-environmentally friendly refrigerant R22.
- Question #307
Through the asset management function, the number of equipment in the computer room can be automatically counted to improve the efficiency of asset inventory.
- Question #308
DC power supply is only used in communication base stations and is not suitable for data centers.
- Question #309
According to Heinrich's Law, the absence of an accident means that no accident will occur.
- Question #310
The function of the collector is to collect signals from UPS, air conditioners, cameras and other equipment.
- Question #311
For air-cooled precision air conditioners, when the outdoor unit is higher than the indoor unit, a reverse U-bend needs to be installed.
- Question #312
The RS485 interface only supports two-wire system, not four-wire system.
- Question #313
The surface cooler controls the indoor temperature by exchanging heat between the refrigerant and the indoor air.
- Question #314
There are generally two types of variable air volume ventilation floors, one is through an adjustable air valve, and the other is a special ventilation floor plus an adjustable fan...
- Question #315
There are three main types of Modbus protocols: Modbus-RTU, Modbus-ASC, and Modbus-TCP
- Question #316
When charging, secondary batteries store electrical energy as chemical energy; when discharging, they convert chemical energy into electrical energy.
- Question #317
ACB circuit breakers are mainly used at the front end of IT loads, such as in UPS output cabinets.
- Question #318
UPS2000-G is an online double-conversion UPS. In normal working state: the AC power provides energy, the rectifier converts AC power into DC power, the inverter converts the rectif...
- Question #319
Huawei NETCol5000 is mainly designed for medium and high density scenarios (>5KW/cabinet)
- Question #320
ATS dual power automatic switching switch can realize fast load-carrying mechanical switching of two power supplies.
- Question #321
CLF is defined as the ratio of power consumption of data center cooling equipment to power consumption of IT equipment.
- Question #322
FM800 has the function of automatic start-up when receiving a call for civil air conditioner
- Question #323
FM1000A V2R3 version 20-foot CT solution supports maximum CT load of 8KW
- Question #324
The operating temperature range of FusinoModule800 is -20-45 degrees, and the operating temperature range of FusinoModule500 is 0-45 degrees.
- Question #325
FUsinoModule1000A V2R3 version 20-foot CT solution is equipped with 4 600*800*2200mm CT cabinets.
- Question #326
FUsinoModule1000A V2R3 version uses Huawei UPS5000E as IT load power supply.
- Question #327
FUsinoModule1000A V2R3 version customized spraying can meet UL120min fire resistance requirements.
- Question #328
FusinoModule1000A V2R3 version can be customized with bulletproof shell.
- Question #329
FusinoModule2000 requires a minimum room height of 2.6 meters.
- Question #330
FusinoModule2000 integrated UPS has two models: 50K/125K.
- Question #331
Netcol5000-A025H half-cabinet row-level variable frequency air-cooled precision air conditioner, Netcol5000-A042H full-cabinet row-level variable frequency air-cooled precision air...
- Question #332
NetCol5000-A042H full-cabinet row-level variable frequency air-cooled precision air conditioner has load-clearing dehumidification function, which can meet the reliable dehumidific...
- Question #333
NetEco management system supports user rights and domain division functions, which can ensure that different operation and maintenance personnel can only view the equipment they ma...
- Question #334
PPUE is an extension of the PUE concept of a data center and is used to evaluate and analyze the energy efficiency of a local area or equipment in a data center.
- Question #335
RER is used to measure the use of renewable energy in data centers to promote the use of renewable energy such as solar energy, wind energy, and hydropower, and to generate zero or...
- Question #336
STS static transfer switch can realize the switching between different input power supplies and provide dual power supply for single power supply load.
- Question #337
The three-phase unbalanced current in the TN-S low-voltage distribution system causes the protective line PS to generate a voltage to the ground.
- Question #338
Common UPS system configurations include N system, N+X system, and 2N system.
- Question #339
UPS can purify the AC input, output stable AC, and protect the load.
- Question #340
UPS inverter components can realize the conversion from AC to DC.
- Question #341
The UPS front-end input can be two mains power lines, one main and one backup, or one mains power line and one diesel generator input.
- Question #342
The N+X system of the UPS system has a higher power supply guarantee level than the 2N system.
- Question #343
UPS-2000-G (6k-10k) battery voltage is 240V, 15K/20 battery voltage is 480v.
- Question #344
UPS2000-G adopts high power density design, 6K/10K is only 2U high, 15K/20K is only 3U high, reducing installation space
- Question #345
UPS2000-G monitors the entire parallel system with one card. The parallel system only needs one communication option card to monitor the entire parallel system.
- Question #346
UPS5000-A-120KVA can support wall installation
- Question #347
UPS5000-A has built-in SNMP and ModBus cards to reduce customers' management investment costs.
- Question #348
UPS-5000-A supports adjustable number of batteries to avoid replacement of the entire battery pack due to failure of a single battery.
- Question #349
UPS5000-E (25-125KVA) does not support iBattery function.
- Question #350
UPS5000-E (25-125KVA) only supports upstream wiring.