H12-411_V2.0 Exam Questions
656 real H12-411_V2.0 exam questions with expert-verified answers and explanations. Page 4 of 14.
- Question #151
Which of the following descriptions of the data center cooling system is wrong?
- Question #152
Which of the following belongs to air-cooled row-level air conditioner?
- Question #153
How many meters can the connecting pipe between the indoor and outdoor units of FusionModule800 air conditioner be shorter than to avoid refrigerant charging?
- Question #154
Which of the following words is the abbreviation of "S" in EHS?
- Question #155
According to the Data Center Design Specification (GB 50174-2017), which of the following levels does the data center infrastructure with redundancy requirements correspond to?
- Question #156
Which of the following components can absorb the moisture in the refrigeration system?
- Question #157
The system grounding form is TN-C. What does the first capital letter mean?
- Question #158
The cable model is ZRC-YJV-0.6/1kV-3?5mm? Which of the following is the meaning of YJV?
- Question #159
As the current frequency increases, how will the inductive reactance of the equipment change?
- Question #160
Which of the following is the relationship between the rated ultimate short-circuit breaking capacity ICU and the rated operating short-circuit breaking capacity ICS of the MCB cir...
- Question #161
In Huawei DC power supplies, which of the following is correct regarding the parameter settings of LLVD and BLVD?
- Question #162
In data center applications, when the city power fails, the battery supplies power to the load. What are the currents output by the battery and UPS?
- Question #163
A battery consists of 6 fixed valve-regulated sealed lead-acid battery cells connected in series, with a rated capacity of 150 Ah. Which of the following is the name of the battery...
- Question #164
Which of the following is not a main component of a lead-acid battery?
- Question #165
Which of the following air supply methods is mainly suitable for process air conditioning where there is a lot of waste heat to be removed from the lower working area?
- Question #166
In the power supply and distribution system of a data center, for which purpose is a low-voltage circuit breaker with three-stage protection characteristics used? (Multiple choice)
- Question #167
Which of the following air conditioners have condensers located outdoors? (Multiple choice)
- Question #168
Which of the following are functions of Huawei's DC power supply AC distribution unit?
- Question #169
What are the throttling devices used in Huawei's air-cooled precision air conditioners? (Multiple choice)
- Question #170
What are the communication methods currently used in dynamic environment monitoring systems? (Multiple choice)
- Question #171
What are the core components of the refrigeration system? (Multiple choice)
- Question #172
Which of the following data center cabinet related performances need to be considered when selecting a cabinet? (Multiple choice)
- Question #173
What functions can the dynamic environment monitoring system achieve? (Multiple choice)
- Question #174
During the construction process, what special equipment is required for nitrogen cylinder operation? (Multiple choice)
- Question #175
Which of the following are common names for grounding systems? (Multiple choice)
- Question #176
In Huawei DC power supplies, which of the following items can trigger the switching of battery charging mode? (Multiple choice)
- Question #177
Based on the degree of concentration of equipment, what types of air conditioning systems can be divided into? (Multiple choice)
- Question #178
Which of the following are the working modes of Huawei's indirect evaporative cooling air conditioner? (Multiple choice)
- Question #179
What are the components of Huawei's dynamic environment monitoring system? (Multiple choice)
- Question #180
What are the components of a lightning protection device? (Multiple choice)
- Question #181
During the construction process, when there are objects falling or impacting, what should be used? (Multiple choice)
- Question #182
Which of the following belongs to the interface? (Multiple choice)
- Question #183
Which of the following descriptions of UPS working modes are correct? (Multiple choice)
- Question #184
Which of the following batteries are secondary batteries? (Multiple choice)
- Question #185
What are the categories of dual power transfer switch ATS according to different transfer switch types? (Multiple choice)
- Question #186
Which of the following () models of air conditioners has an oil separator? (Multiple choice)
- Question #187
What systems does the computer room fire protection system mainly consist of? (Multiple choice)
- Question #188
What are the three major indicators of air conditioning? (Multiple choice)
- Question #189
What applications can the dynamic environment monitoring system be applied to? (Multiple choice)
- Question #190
What functions does Huawei's NETECO monitoring system support? (Multiple choice)
- Question #191
What functions can be realized in the access control system interface? (Multiple choice)
- Question #192
Which of the following are the switching types of ATS? (Multiple choice)
- Question #193
Based on the type of electrolyte, what types of lead-acid batteries can be divided into? (Multiple choice)
- Question #194
Which of the following are the functions of UPS? (Multiple choice)
- Question #195
While installing UPS, air conditioner and other equipment, which of the following personal protection measures are required? (Multiple choice)
- Question #196
Which of the following are components of Huawei's indirect evaporative cooling system? (Multiple choice)
- Question #197
Which of the following description of the rectifier components of high-frequency UPS is correct? (Multiple choice)
- Question #198
What scenarios are computer room air conditioners suitable for? (Multiple choice)
- Question #199
What functions does the valve-regulated sealed lead-acid battery safety valve have? (Multiple choice)
- Question #200
During the construction process, what should be used for low-voltage live work (below 1KV)? (Multiple choice)