- Question #451
UPS5000-E (50KVA module) supports adjustable number of batteries, avoiding the replacement of the entire battery pack due to a single battery failure, and solving the problem of di...
- Question #452
As long as you buy the Huawei mobile APP function, you can check the operation status of the computer room at home
- Question #453
One of the highlights of UPS2000-G series products is high efficiency. It is the first batch of UPS in the industry to pass Energy Star certification.
- Question #454
The demand for government cloud computer room construction only exists in provinces and cities, and there is no opportunity in districts and counties.
- Question #455
The main circuit of PDU8000 precision power distribution cabinet supports voltage harmonic and current harmonic monitoring.
- Question #456
Configure a modular redundant UPS system. As long as the number of modules meets the basic requirements, there is no need to consider the distribution of UPS modules on different r...
- Question #457
The 12V battery is composed of 6 2V battery cells.
- Question #458
In the air conditioning system, the function of the oil-gas separator is to separate the lubricating oil brought out by the compressor exhaust and return the separated lubricating...
- Question #459
Data centers usually use gas fire protection systems.
- Question #460
R410a refrigerant will produce a greenhouse effect and damage the ozone layer.
- Question #461
The intelligent rPDU in FusionModule2000 version 3.0 can control the switch of each socket.
- Question #462
Configure the UPS cables so that the total current carrying capacity of the cables is greater than the rated current of the UPS to meet the project requirements.
- Question #463
The leakage current protector is based on the fact that after the current exceeds the specified value for a period of time, the heat generated by itself will melt the melt, thereby...
- Question #464
Huawei micromodules can seal cold channels as well as hot channels
- Question #465
Huawei's self- developed air conditioner has a 6KV lightning protection filter function, the highest in the industry.
- Question #466
NetEco management system supports remote alarm notification via SMS, email, etc., prompting users to handle alarms as soon as possible.
- Question #467
UPS5000-A built-in isolation transformer
- Question #468
Battery packs of different brands and the same capacity can be used in parallel.
- Question #469
When configuring batteries, you don't need to consider the brand of the batteries, as long as the capacity is the same, it can meet customer requirements.
- Question #470
UPS5000-E (50kVA power module) can accommodate up to 300kVA in a single rack.
- Question #471
DB9 is a protocol.
- Question #472
PLE is defined as the ratio of power consumption of the data center power supply and distribution system to that of IT equipment.
- Question #473
UPS5000-A 30~120kVA can support wall installation.
- Question #474
The UPS5000-A parallel signal line does not adopt a ring connection method, which results in a single point of failure and reduces system reliability.
- Question #475
UPS5000-A supports adjustable number of batteries to avoid replacement of the entire battery pack due to failure of a single battery, solving the problem of difficult maintenance o...
- Question #476
UPS5000-E (50kVA power module) has a single cabinet capacity of 300kVA and can support 8 racks in parallel.
- Question #477
The UPS5000-S power module has a capacity of 50kVA and a height of 2U, with the highest power density in the industry.
- Question #478
UPS5000-S has the function of adjusting the number of batteries, which avoids the replacement of the entire set due to a single battery failure and solves the problem of difficult...
- Question #479
Huawei air-cooled air conditioners (25kw and 42kw) have one indoor unit corresponding to one outdoor unit
- Question #480
Huawei monitoring system NETECO supports hierarchical network management functions. ()
- Question #481
Three-proof paint coating can significantly reduce the failure rate of UPS in harsh environments such as salt spray, dust, high temperature and humidity, and ensure its service lif...
- Question #482
The integrated UPS is equipped with a lightning protection module
- Question #483
During manual construction, use pushing and pulling instead of carrying as much as possible to reduce the risk of muscle sprains and strains.
- Question #484
The main monitoring objects of the data center computer room monitoring system include power supply system, refrigeration system, fire protection system, etc.
- Question #485
Data center power supply and distribution systems usually use low-voltage generator sets. When the power supply distance is long and the system load is large, high-voltage generato...
- Question #486
PC-level ATS has the functions of connection and load-bearing, but is not used to disconnect short- circuit current.
- Question #487
In the TN-C system, in order to protect the safety of equipment and lines, it is recommended to install a circuit breaker on the PEN line.
- Question #488
The main functions of MCB circuit breaker include short circuit protection and overload protection.
- Question #489
The cables of a certain project will be subjected to great tensile force during use. When the current carrying capacity of the cables just meets the line requirements, Engineer A s...
- Question #490
UPS can purify the AC input, output stable AC, provide uninterrupted power supply and protect the load.
- Question #491
When chemical reactions occur inside VRLA batteries, hydrogen and oxygen are produced and water is consumed, so VRLA batteries need to be replenished regularly.
- Question #492
Lithium has very active chemical properties and is very easy to burn. By managing the charging current through BMS, the internal temperature of the battery can be prevented from be...
- Question #493
Lead-acid batteries can be used directly under sunlight, but good ventilation is required.
- Question #494
During discharge, Li+ is released from the negative electrode and embedded in the positive electrode (gaining electrons).
- Question #495
Compared with lithium-ion batteries, lead-acid batteries have lower energy density, short cycle life and poorer safety, but the initial investment in lead-acid battery projects is...
- Question #496
The refrigerant undergoes phase change in the evaporator, absorbs heat, and takes away the heat of the refrigerated object to achieve refrigeration.
- Question #497
The air static pressure in the air conditioning system refers to the relative static pressure.
- Question #498
Water-cooled direct expansion air conditioners generally require the use of a mixed solution of water and ethylene glycol.
- Question #499
The essential difference between water-cooled direct expansion air conditioning and water-cooled chilled water air conditioning is whether a cooling tower is used.
- Question #500
The oil separator is generally installed between the evaporator and the compressor to facilitate the return of the lubricating oil to the compressor.