E20-880 Exam Questions
247 real E20-880 exam questions with expert-verified answers and explanations. Page 5 of 5.
- Question #201
Which action would be most effective in reducing the performance impact of a Snapshot on a Source LUN?
- Question #202
A customer has a VNX system to provide storage for a VMware Cluster with five ESX hosts. Each ESX host has one dual-port FC HBA connected to two FC switches. They are using VMware...
- Question #203
A customer would like to configure their VNX for File for the highest possible level of client availability. There are five Ethernet ports on a single DataMover and a single Ethern...
- Question #204
A customer would like to use five Ethernet ports on a VNX to increase the port and switch availability. Two non-stackable Ethernet switches are available for the VNX and both suppo...
- Question #205
A client has asked for assistance with designing his Exchange environment. The environment today is fully virtualized and Exchange will be as well. The client is concerned about lo...
- Question #206
A customer has created a thin LUN, enabled compression on a LUN Pool, and installed their Exchange environment. The Exchange application is showing poor performance. Which workload...
- Question #207
A customer is experiencing performance issues during their anti-virus scanning in their VMware environment. They have determined the problem to be a storage issue. Full clones on S...
- Question #208
A Customer is planning to build a VDI environment on a VNX array. The customer is working to determine what type of VM replicas would be acceptable in their environment. It needs t...
- Question #209
A Customer is planning to build a VMware DTaaS environment on a VNX array. The customer is deciding what type of VM replicas would be acceptable in their environment. It needs to h...
- Question #210
A customer built a VDI on a VNX array. The customer currently has only NL-SAS drives. The customer wants to simulate I/O characteristics of users accessing the storage from the vir...
- Question #211
Click the calculator icon in the upper left-hand corner. A customer is building out a VDI environment of 1000 light users and 50 heavy users. They plan to use Boot from SAN for all...
- Question #212
What factors can be used to determine the number of IOPs per desktop that a VNX will need to satisfy during the boot of a virtual desktop?
- Question #213
A company needs to create clone LUNs on a VNX storage system. These LUNs will be used by Replication Manager to back up a Microsoft Exchange server database and log LUNs. Where mus...
- Question #214
A customer is running a data warehouse server with dual HBAs connected to a SAN. A performance analysis of the server shows high utilization. This server needs to be backed up to a...
- Question #215
A customer's database resides on a RAID 5 Pool with SAS drives. Which best practice should be followed to optimize Reserved LUN Pool disk performance?
- Question #216
A customer is supporting 800 Exchange users on a VNX5700. The users are divided among four Exchange storage groups using a total of eight LUNs each for data and logs and two LUNs f...
- Question #217
A customer implemented full SAN Copy with default settings in order to copy 60 DMX array volumes to a VNX storage system. After several hours, they determine that the process is ta...
- Question #218
A customer has deployed a new application on a host using VNX storage. The new application I/O size is 512 KiB, has a 50/50 read-write ratio, and its write behavior is sequential a...
- Question #219
An application generates 500 random 8 KiB IOPS with a R/W ratio of 3:1. An asynchronous mirror is started on the application LUN. The update cycle is configured to be 30 minutes, a...
- Question #220
As a result of suffering a catastrophic failure, your customer has requested a DR solution. The solution must introduce a higher level of availability for their Exchange 2010 syste...
- Question #221
A customer has recently implemented Microsoft Exchange 2010 on a VNX storage system that hosts a variety of application servers. The Exchange implementation is currently using RAID...
- Question #222
A clone source LUN is 512 GiB in size. It performs 500 random 8 KiB IOPs with a 3:1 R/W ratio. As part of ongoing testing, the clone is fractured for 10 minutes and then resynchron...
- Question #223
A customer with an existing VNX for File implementation wants to enable deduplication on a file system, based on the following specifications: - Idle File System - Number of files:...
- Question #224
A customer has a VNX system to provide storage for a VMware 4.1 Cluster with 4 ESX hosts. MS Exchange servers and other application servers will be hosted on VMs. The customer want...
- Question #225
You are working with a customer that recently refreshed their hardware with a VNX storage system configured with Flash drives. During this swap customer also migrated their Exchang...
- Question #226
A company recently purchased a VNX storage system to support its clustered SQL Server environment. You are designing the disk layout. Based on EMC best practices, what design chara...
- Question #227
A customer is migrating an application to a virtualized environment. After the implementation is completed they realize that performance is below their expectations. You are tasked...
- Question #228
You have designed a VNX for File solution for a creative content provider. The solution involves 10, 2 TiB file systems. Each file system has a Checkpoint taken every hour, refresh...
- Question #229
Your customer recently upgraded their IP switch hardware. Since the upgrade, the customer is experiencing performance degradation on certain NFS exports configured on a VNX for Fil...
- Question #230
A Storage Administrator with a VNX Unified solution is using the CLI to monitor daily storage performance. They must type long commands to examine the statistical types and names t...
- Question #231
A VNX for File administrator is implementing SnapSure for backup staging. The administrator is concerned that this solution might affect the Production File Systems (PFS). You are...
- Question #232
A customer is using a virtualized environment with a large number of NFS datastores presented from a VNX system. They are experiencing more than expected network traffic on their d...
- Question #233
A customer with a virtualized environment has asked you to architect a new VNX storage solution utilizing their many NFS datastores. They are also deploying a new Cisco Unified Com...
- Question #234
Your customer is reporting less than optimal performance for their online payment processing application. The payment processing application is running on a Windows Server cluster...
- Question #235
A customer wants to mark an Incremental SAN Copy Session at 12:00 UTC, and start the transfer of data at 20:00 UTC. Their data access pattern consists of small block I/O, with arou...
- Question #236
Exchange 2010 is being implemented on a pair of VNX storage arrays. There will be a production site and a DR site, each with two servers and one VNX storage array. EMC RecoverPoint...
- Question #237
A customer is implementing a VNX for File solution in a performance-oriented application environment. There are Windows and Linux VM clients accessing the file systems. The custome...
- Question #238
Your customer is reporting less than optimal performance for their online payment processing application. The payment processing application is running on a Windows Server cluster...
- Question #239
If an SP fails within a VNX system, how many drives can the surviving SP address at the same time if array ports 0 and 2 are used?
- Question #240
Your customer has a Microsoft SQL installation on a VMware guest Windows 2003 Server using RDM. The ESXi server uses a VNX system. What would you recommend to your customer to avoi...
- Question #241
You are conducting an analysis of a Celerra system to migrate the data to a new VNX Unified storage subsystem. You want to collect statistical information about the CIFS sub-system...
- Question #242
Your customer has LUNs with a total size of 25,000 GiB. The total I/O load is 10,000 IOPS, with a 4:1 R/W ratio. Analysis of your customer's data indicates that data skew is 95%. R...
- Question #243
A customer is interested in implementing SSDs to improve response time for a sensitive database that generates mostly small random reads. The compute platform for this customer is...
- Question #244
During a migration from a Windows server to a VNX for file how should virus scanning for the VNX be configured?
- Question #245
When will subsequent compressions occur on a LUN that has compression enabled?
- Question #246
Click the calculator icon in the upper left-hand corner. A Snapshot Source LUN performs 650 random 16 kB IOPs, with a 4:1 R/W ratio. At what rate is chunk data written into the RLP...
- Question #247
Click the calculator icon in the upper left-hand corner. A clone source LUN is 2 TB in size. It performs 450 random 16 kB IOPs with a 2:1 R/W ratio. As part of ongoing testing, the...