- Question #1
Before deploying a server, a customer needs a technician the front panel LCD to display a customer message that contains the customer's help desk phone number. However, the server...
- Question #2
A technician needs to remotely update the iDRAC with Lifecycle Controller firmware. They have downloaded the latest iDRAC firmware to the management station and connected to the iD...
- Question #3
A technician is sent on-site to troubleshoot a server that reports errors during POST when rebooted. The following error message is displayed "Correctable memory error rate exceede...
- Question #4
A sever is configured with a RAID 5 Virtual Disk across live hard disks and one spare disk. If a hard disk failure occurs within me RAID 5 virtual disk. The spare disk needs to be...
- Question #5
A technician needs to replace a server component with orange tabs/releases. Which set of paired steps should the technician take to complete this task?
- Question #6
A technician is change me iDRAC IP address from, the static IP address 10 37 125 88 to DHCP on the technician PowerEdge R640 that does not have a front LCD. After completing this t...
- Question #7
A server is being set up as a VMware ESXi host. A technician needs to install the OS on an internal SD card. They install the SD card However, during OS installation, the SD card i...
- Question #8
A user has a fully configured PowerEdge R640 and an iSM installed on their Windows. 2016 operating system. They now want to install OMSA to enable them to have alerts sent out In-B...
- Question #9
A technician is configuring a PowerEdge R640 that has two PSUs. The tack in which it is being installed has two power distribution units (POUs) No high power such as GPUs are requi...
- Question #10
A technician must update the firmware on a savor, but has no network connectivity. What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?
- Question #11
A technician needs to configure a server to PXE boot a server setup image with the BIOS in UEFI mode. What action is required to enable this function?
- Question #12
A technician is remotely installing EXI 6.0 on a powerEdge R640 in BIOS boot mode. The system has dual internal SD cards Alter the OS is installed, the system reboots and shows an...
- Question #13
A server has the following configuration: - 5x 1 TB drives configured in a RAID 5 array - 1x 1 TB as a global hoi spare - Persistent Hoi Spare Slot enabled A user adds one addition...
- Question #14
A PowerEdge R640 service has a failure on one of its onboard NlCs and sends on alert to technical support. The assigned technician needs to order a FRU to resolve the issue. What a...
- Question #15
A user has a service with only one processor installed with 6x 32 GB ROIMMs A technician was asked to install a second processor After installing the second processor, the technici...
- Question #16
A technician needs to troubleshoot a server The OS had been operational, but an untrained person accessed (ho System Setup utility on the server and now the OS lads to load The tec...
- Question #17
A technician is sent on- site to troubleshoot a server that produced an error message during the most recent POST but then completed the POST and booted to the operating system. Th...
- Question #18
A server is equipped with 2 CPUs and 12x 8 GB DlMMs. for a total of 96 GB The OS is not seeing all the memory. Which memory mode should be configured so that all memory is seen by...
- Question #19
A technician receives a repurposed PowerEdg server. After racking and cabling the server. The technician attempts to log into the iDRAC but cannot do so. The default login account...
- Question #20
A technician needs to repurpose a server. The server has dual processors with 18 cores each The OS only sees 24 threads in total. Which setting should the technician change in Proc...
- Question #21
A technician needs to add a device to SupportAssisI Enterprise Policy requires that no additional software be installed on the server OS. In addition to Username and Password, what...
- Question #22
A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PoworEdge 14G servers. Each server has the following configuration...
- Question #23
A technician is troubleshooting a server with the following components - Two CPUs - Memory installed in sockets A1,A2, A3, A4, A5, A6, B1, B2,B3, 64, B5, and B6 - Expansion cards i...
- Question #24
What can a technician do to ensure that no malicious code can be introduced into any of the servers through physical access?
- Question #25
A technician wants to move memory from a few older systems. What is the most efficient method to accomplish this task?
- Question #26
A technician needs to install several firmware updates on a server. The server cannot be rebooted until the customer performs a routine reboot. What method should the technician us...
- Question #27
A technician has the ISO imago of an OS that they need to install on a server m a remote location. They are already logged into the iDRAC. How should the technician install the OS?
- Question #28
A technician is on-site to update firmware on a server lot which the iDRAC is not configured in addition, the technician does not have access to the OS. However, the site does have...
- Question #29
After a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster in the future, even at the expense of stowing users down How s...
- Question #30
A system administrator needs to install OpenManage Server Administration on 200 servers. What is the quickly way to meet this requirement?
- Question #31
A technician needs to set a server to always attempt PXE boot before booting to the achieve this?
- Question #32
A technician is setting up a previously used server. Upon power up the PERC alerts them to the presence of a foreign configuration in the iDRAC storage section. The technician chec...
- Question #33
A technician needs to connect a server to a network switch the network switch has only two available network ports so only two network cables can be connected. The user needs as mu...
- Question #34
A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. They also create a global hot spare. A drive fails on the second virtual disk what is...
- Question #35
A technician needs to deploy a server into production and needs lo verily that the firmware levels match corporate policy before putting the server on the business network. Which m...
- Question #36
Refer to the exhibit. A technician tries to apply s BIOS update on a sever through the iDRAC wed interface using the Linux Dell Update Package filo BIOS _2M4CC_LN_2 0 2 BIN. This r...
- Question #37
A new Dell customer is ordering servers that have very specify firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The pro...
- Question #38
A technician is installing a new server and is not getting any link lights on the iDRAC management port. They have verified that the cable and switch port are working. What could b...
- Question #39
A technician plugs in a sever that has dual power supply units. After powering on the system, they notice that the power supply status indicators blink green then turn. What troubl...
- Question #40
A technician deletes the iDRAC Express license on a R440 server. Which license type is then enabled?
- Question #41
Which tool provides automated Dell support case creation?
- Question #42
Eight new savers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable those service id contact the DHCP server on the network lo obta...
- Question #43
A technician needs to install the OS on a server remotely using iDRAC. What is the minimum iDRAC license required to perform this task?
- Question #44
A technician needs to use the iDRAC GUI to toil back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be fou...
- Question #45
A technician is experiencing a compatibility issue that causes network disconnects between the iDRAC firmware and an application that is running. The iDRAC must be rolled back to t...
- Question #46
A technician is creating a virtual disk in the DRAC (2x 4 TB NL-SAS in RAID 1) lo install Windows 201$ They manually boot to the OS installation media without using (he lifecycle C...
- Question #47
A technician needs to repurpose a server. What should they do to prepare the server for its new role?
- Question #48
What operation should a technician perform to ensure configuration recovery if a server must be physically replaced'
- Question #49
A technician is working on an operational PowetEdge R640 server that cannot be rebooted Observing that all the drives are hot-swappable devices, the technician decides to remove a...
- Question #50